Technical Parameter Specification Value
Product Model / Part Number RSER200-4 / 603444
Product Type / Function Remote I/O 4-Channel Serial Line Interface Module
System Architecture Kongsberg RIO200 System / RBUS Backplane
Serial Channels 4 optically and galvanically isolated channels
Supported Protocols / Interfaces Software-selectable RS-232, RS-422, RS-485, and NMEA 0183
Backplane Interface RBUS backplane (for system power and controller communication)
Local Diagnostics Front-panel status LEDs, USB service port
Dimensions (W × H × D) 35 mm × 130 mm × 130 mm
Net Weight Approx. 0.34 kg
Mounting Type 35 mm EN 60715 top-hat DIN rail / dual-rail placement
Marine Compliance Standards IEC 60945, IACS E10
Categories: , , , , SKU: RSER200-4 603444 Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The Kongsberg RSER200-4 (Part Number 603444) is a remote I/O serial line interface module engineered for marine automation and industrial process control applications. Operating as a key communication component within the Kongsberg RIO200 system family, the unit provides reliable data integration between field instrumentation, marine navigation systems, and host control systems (such as Remote Control Units).

Featuring four galvanically isolated serial channels, each port can be software-configured to support RS-232, RS-422, RS-485, or NMEA 0183 communication protocols. The module receives power and exchanges process data via the RBUS backplane interface, incorporates front-panel status LEDs and a USB service port, and is constructed to meet marine environmental standards for equipment-space installations.

 

Key Technical Specifications

Technical Parameter Specification Value
Product Model / Part Number RSER200-4 / 603444
Product Type / Function Remote I/O 4-Channel Serial Line Interface Module
System Architecture Kongsberg RIO200 System / RBUS Backplane
Serial Channels 4 optically and galvanically isolated channels
Supported Protocols / Interfaces Software-selectable RS-232, RS-422, RS-485, and NMEA 0183
Backplane Interface RBUS backplane (for system power and controller communication)
Local Diagnostics Front-panel status LEDs, USB service port
Dimensions (W × H × D) 35 mm × 130 mm × 130 mm
Net Weight Approx. 0.34 kg
Mounting Type 35 mm EN 60715 top-hat DIN rail / dual-rail placement
Marine Compliance Standards IEC 60945, IACS E10

 

Detailed Product Overview

The Kongsberg RSER200-4 (603444) serves as a specialized communications bridge in marine vessel management, dynamic positioning, and offshore control architectures. Designed to extend the serial interface capabilities of the RIO200 remote I/O platform, it converts field serial streams into standardized RBUS backplane signals for direct processing by centralized controllers.

Each of the module’s four ports is individually software-configurable. This capability enables the simultaneous interfacing of diverse equipment types—such as point-to-point RS-232 devices, multidrop RS-485 networks, balanced RS-422 serial lines, and marine-standard NMEA 0183 navigation instruments—on a single hardware module. Optical isolation across the channels prevents ground loops and safeguards delicate control electronics against voltage transients common in marine electrical distribution systems.

For system maintenance and deployment, the RSER200-4 includes a dedicated USB service port for local diagnostics and parameter verification. Its compact 35 mm footprint allows high-density cabinet mounting alongside other RIO200 series modules.

RSER200-4 603444

RSER200-4 603444

RSER200-4 603444

RSER200-4 603444

Engineering Selection Highlights

  • Flexible Protocol Support: Software-selectable port modes (RS-232, RS-422, RS-485, NMEA 0183) eliminate the need for distinct hardware cards for each serial standard.
  • Galvanic & Optical Isolation: Individual channel isolation protects internal controller circuitry from high-voltage spikes and field-side electrical interference.
  • Integrated Marine Design: Built to satisfy IEC 60945 and IACS E10 standards, providing environmental resilience for marine and offshore installations.
  • Direct RBUS Connectivity: Connects directly into the RIO200 base carrier backplane for reliable power distribution and host system integration.
  • Service Accessibility: Embedded front-panel USB port and channel LED indicators simplify field diagnostics and communication troubleshooting.

 

Dimensions, Mounting & Connection Notes

  • Module Dimensions: Width: 35 mm, Height: 130 mm, Depth: 130 mm.
  • Weight: 0.34 kg.
  • Mounting Standard: Dual DIN rail mounting (35 mm EN 60715 top-hat standard).
  • Placement: Installs onto the RIO200 system carrier base, engaging backplane connections upon seating.
  • Environmental Operating Range: Designed for marine machinery space and equipment room environments, conforming to standard operational requirements (typically −15 °C to +55 °C).

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
System Platform Kongsberg RIO200 Remote I/O System Connects to host controllers via RBUS protocol
Carrier / Base RIO200 RBUS Base/Power Unit Provides physical mounting, backplane power, and signal bus access
System Power 24 VDC regulated via RIO200 base unit Powered directly from the RBUS backplane
Local Diagnostics USB interface Accessible via front-panel USB port for engineering access

 

FAQ

What is the Kongsberg RSER200-4 603444?

The Kongsberg RSER200-4 (part number 603444) is a 4-channel, galvanically isolated serial line interface module used within the RIO200 remote I/O system.

Which serial protocols does the RSER200-4 support?

Each of its four channels can be independently configured for RS-232, RS-422, RS-485, or NMEA 0183 protocols via software.

What system backplane does this module require?

The module mounts onto and connects through the Kongsberg RIO200 RBUS carrier base unit for power delivery and controller communication.

Does the RSER200-4 support local maintenance?

Yes, it features front-panel LED status indicators and an integrated USB service port for local diagnostic access.

 

Verification & Troubleshooting Notes

  • Port Status Inspection: Monitor the front-panel status LEDs to confirm power delivery, active backplane data flow, and individual port transmit/receive activity.
  • Service Port Access: Utilize the front USB port to attach a technician interface tool to check baud rate settings, protocol assignment, and communication traffic logs.
  • Backplane Engagement: Ensure the module is fully seated on the 35 mm DIN rail carrier base so that RBUS backplane connector pins maintain consistent electrical contact.