Sale!

Kyowa WGA-200A Compact Strain Gage Signal Conditioner

Parameter Specification
Manufacturer Kyowa Electronic Instruments
Model / Type Code WGA-200A
Device Type Strain gage signal conditioner / instrumentation amplifier
Compatible Sensors Strain gage transducers (Load cells, pressure, torque, displacement)
Bridge Excitation Voltage Stable DC bridge power supply
Analog Output Options Voltage (0 to 10 V / ±10 V) and Current (4 to 20 mA) output models
Calibration / Adjustment Front-panel fine Zero and Span adjustment trimmers
Mounting Format 35 mm DIN-rail mount or panel screw mount
Response Frequency Wideband analog signal response for high-speed dynamic measuring
Categories: , , , , SKU: WGA-200A Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The Kyowa WGA-200A is a compact, high-speed strain gage signal conditioner designed to convert sensor outputs from strain gages, load cells, and pressure transducers into standard analog signals. Functioning as a conditioning amplifier within Kyowa’s industrial measurement equipment lineup, this module delivers high-accuracy signal processing for automated process monitoring, quality control, and testing applications.

Operating on a standard AC or DC power configuration, the WGA-200A provides stable bridge excitation voltage to connected strain-gage transducers while amplifying microvolt-level bridge outputs into high-level voltage or current signals (such as 0 to 10 V or 4 to 20 mA). Designed for control panel mounting via DIN-rail track or screw mounting, the unit features fine zero and span adjustment trimmers on the front panel to enable rapid calibration during machine commissioning.

 

Key Technical Specifications

Parameter Specification
Manufacturer Kyowa Electronic Instruments
Model / Type Code WGA-200A
Device Type Strain gage signal conditioner / instrumentation amplifier
Compatible Sensors Strain gage transducers (Load cells, pressure, torque, displacement)
Bridge Excitation Voltage Stable DC bridge power supply
Analog Output Options Voltage (0 to 10 V / ±10 V) and Current (4 to 20 mA) output models
Calibration / Adjustment Front-panel fine Zero and Span adjustment trimmers
Mounting Format 35 mm DIN-rail mount or panel screw mount
Response Frequency Wideband analog signal response for high-speed dynamic measuring

 

Detailed Product Overview

The Kyowa WGA-200A signal conditioner acts as an analog interface between raw strain-gage-based sensors and downstream automation controllers such as PLCs, data acquisition (DAQ) cards, or panel meters. Because raw Wheatstone bridge outputs from load cells or force sensors produce very low voltage levels, direct PLC input is susceptible to noise and resolution loss. The WGA-200A conditions, filters, and amplifies these low-level sensor signals locally before transmission to control devices.

Built into a compact industrial enclosure, the module incorporates low-noise operational amplifiers, stable voltage regulators for bridge excitation, and selectable active filters to eliminate mechanical vibration and electromagnetic interference (EMI). The front panel provides clear zero and gain calibration controls, allowing commissioning engineers to tune system offset and span without requiring external software tools.

This signal conditioner is commonly deployed in industrial automation setups, including automated press-fit force monitoring, structural load testing, inline tank weighing, material testing stands, and automated assembly line process verification.

 

Engineering Selection Highlights

  • High-Accuracy Conditioning: Amplifies low-level Wheatstone bridge outputs into noise-immune analog voltage or current loop signals.
  • Stable Bridge Excitation: Onboard regulated power supply maintains consistent transducer excitation voltage to prevent signal drift.
  • Front-Panel Trimmers: Manual zero adjustment and span calibration controls streamline field installation and maintenance.
  • DIN-Rail Compatibility: Compact panel housing snaps directly onto 35 mm DIN rails for simple control enclosure integration.
WGA-200A

WGA-200A

WGA-200A

WGA-200A

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Transducer Input 4-wire or 6-wire strain-gage transducers Compatible with standard load cells, pressure sensors, and torque transducers.
Output Destination PLC analog input modules, DAQ cards, panel meters Choose voltage (0–10 V) or current loop (4–20 mA) model variant based on controller input specs.
Power Supply Specified AC or DC operating power Verify power model requirement (AC line voltage or 24 V DC) prior to wiring supply lines.
Signal Wiring Shielded multi-conductor sensor cabling Connect sensor shield to system ground at single point to prevent ground loops and EMI noise.

 

Dimensions, Mounting & Connection Notes

  • Mounting Options: Mounts via standard 35 mm DIN rail or panel surface using mounting holes.
  • Terminal Wiring: Terminal blocks accommodate wiring for power supply, transducer input lines (excitation +/- and signal +/-), and analog output signals.
  • Grounding Requirements: Requires dedicated ground wiring to terminal chassis ground to ensure proper noise rejection and signal stability.
  • Operating Environment: Install inside protective enclosures (IP54 or better) away from high-voltage motor drives and induction heating devices to avoid thermal drift and electrical interference.

 

FAQ

What is the primary function of the Kyowa WGA-200A?

The Kyowa WGA-200A is a signal conditioner card that amplifies low-level signal outputs from strain gages and load cells into standardized analog signals for PLCs and data acquisition systems.

What types of sensors connect to the WGA-200A?

It connects to strain-gage-based sensors, including load cells, force transducers, pressure sensors, torque meters, and displacement transducers.

How is the WGA-200A calibrated in the field?

The front panel features accessible zero and span potentiometer trimmers that allow technicians to calibrate zero offset and output gain manually using a reference load or simulator.

Can the output signal be wired directly to a PLC?

Yes, the amplified analog outputs (0–10 V or 4–20 mA depending on configuration) connect directly to standard PLC analog input channels.

How is the module mounted inside an industrial cabinet?

The WGA-200A features a compact design suitable for mounting on standard 35 mm DIN rails or direct panel mounting inside control boxes.

 

Verification & Troubleshooting Notes

  • Verify Excitation Voltage: Measure excitation terminals with a digital multimeter to confirm that stable voltage is delivered to the sensor bridge.
  • Check Sensor Resistance: Disconnect sensor wiring and check input/output resistance across bridge legs to confirm transducer integrity before troubleshooting the amplifier card.
  • Zero Offset Drift: If output zero drifts, verify panel grounding integrity and ensure sensor cable shields are grounded at one end only.
  • Confirm Signal Output Limits: Ensure target PLC input scaling matches the amplifier’s output range (e.g., 0–10 V range setting) to prevent clipping or measurement errors.