Sale!

LEM LF 1005-S/SP16 Closed Loop Hall Effect Current Sensor

  • Model: LF 1005-S/SP16 (LF1005-S/SP16)
  • Brand: LEM
  • Series: LF Series Closed Loop Hall Effect Transducers
  • Core Function: Measures DC, AC, and complex waveform currents with galvanic isolation.
  • Product Type: Closed Loop (Compensated) Current Transducer
  • Key Specs: 1000 A Nominal RMS Current | 1:2000 Turns Ratio | ±12 V to ±24 V DC Dual Supply
  • Condition: New Original / New Surplus
  • Inventory Status: Legacy / High-demand OEM component — strategic buffer stock required for inverter and drive maintenance.
Categories: , , , , SKU: LF 1005-S/SP16 Brand:

Description

Key Technical Specifications

Parameter Specification / Value
Model Number / Part Number LF 1005-S/SP16 / LF1005-S/SP16
Manufacturer LEM International SA
Measurement Technology Closed Loop Hall Effect (Compensated)
Primary Nominal Current (I_{PN}) 1000 A RMS
Primary Measuring Range (I_{PM}) 0 to ±1500 A
Secondary Nominal Current (I_{SN}) 500 mA (at I_{PN} = 1000 A)
Conversion Ratio (Turns Ratio) 1:2000
Supply Voltage (V_C) ±12 V DC to ±24 V DC (±5%)
Accuracy / Linearity Overall accuracy @ I_{PN} = \pm 0.3\%; Linearity < 0.1\%
Frequency Bandwidth DC to 150 kHz (−1 dB)
Response Time (t_r) < 1 \mus (at 90\% of I_{PN})
Isolation / Dielectric Strength 6 kV RMS / 50 Hz / 1 min
Operating Temperature −40 °C to +85 °C (−40 °F to +185 °F)
Enclosure Rating UL 94-V0 polycarbonate housing
Unit Weight 1.5 kg (3.3 lbs)

 

Product Introduction & Supply Chain Strategy

The LEM LF 1005-S/SP16 is a high-precision, closed-loop Hall effect current transducer engineered for high-power industrial applications, including variable frequency drives (VFDs), solar inverters, traction converters, uninterruptible power supplies (UPS), and welding equipment. Utilizing compensated closed-loop technology, it provides high dynamic accuracy, exceptional linearity, and sub-microsecond response times while maintaining complete galvanic isolation between primary high-power circuits and secondary control logic.

Because lead times for high-capacity LEM current sensors can fluctuate or face production allocations, keeping authentic New Surplus LF 1005-S/SP16 units in your maintenance inventory is essential for supply chain resilience. Replacing a failed transducer with a used or unverified component introduces severe risks, such as thermal drift, offset calibration errors, or dielectric breakdown that can destroy downstream control boards. Sourcing factory-sealed New Surplus units guarantees original magnetic core integrity, factory-calibrated turns ratios, and zero operational degradation, preventing costly downtime during drive or inverter overcurrent faults.

 

Installation & Configuration Guide

High Current & Busbar Voltage Hazard

High-voltage primary busbars carry lethal current and voltage levels. Ensure main power feeds are isolated using strict Lock-Out/Tag-Out (LOTO) procedures before positioning the transducer or handling primary busbar connections.

1.Pre-Installation & Safety Prep:5 mins.

Perform LOTO on the primary inverter or power cabinet supply. Wear an ESD-grounded wrist strap before touching secondary control terminals. Inspect the internal aperture and mounting lugs of the transducer for cleanliness.

2.Mechanical Mounting & Busbar Insertion:10 mins.

Pass the primary busbar or cable centrally through the inner measuring aperture. Secure the transducer chassis onto the mounting panel using non-magnetic M5/M6 hardware to avoid distorting the magnetic core field.

3.Secondary Signal & Power Wiring:10 mins.

Connect the secondary control terminals (+V_C, −V_C, Output Signal M, and Earth Ground). Use twisted-shielded cable for the secondary output signal M to minimize electro-magnetic interference (EMI) from adjacent switching components.

4.Power-On & Signal Verification:5 mins.

Restore control logic power (±15 V to ±24 V DC). Measure the secondary output current across the measuring resistor (R_M). Verify zero-current offset (I_O \le \pm 0.5 mA) before applying primary load current.

Verification: The secondary output signal must track primary current linearly at a 1:2000 ratio (0.5 A output per 1000 A primary) without current clipping, phase distortion, or signal saturation alarms on the drive controller board.

 LF 1005-S/SP16

LF 1005-S/SP16

Firmware/Software Versions & Upgrade Notes

  • Analog Sensing Component: The LF 1005-S/SP16 is an analog hardware sensor and contains no flash software or programmable microcontrollers. No software downloads or firmware flashing are required during replacement.
  • Measuring Resistor (R_M) Selection: Ensure the burden/measuring resistor (R_M) connected to the secondary output pin matches your controller board design parameters. Selecting an improper R_M value relative to your supply voltage (V_C) can cause output clipping at peak currents.
  • Grounding Consideration: Always connect the internal shielding terminal/screen directly to cabinet earth ground to maintain high immunity against high dV/dt switching noise common in modern IGBT/SiC power converters.

 

Frequently Asked Questions (FAQ)

Is this LEM LF 1005-S/SP16 transducer genuine new stock or refurbished?

This sensor is Brand New Surplus. It is not a pulled component, second-hand unit, or refurbished sensor. It features pristine magnetic core assembly, factory-original secondary windings, and un-degraded internal Hall element circuitry.

Why shouldn’t our plant buy second-hand or pulled current transducers?

Used current sensors pulled from high-power equipment have often been subjected to extreme thermal cycles and high-current fault surges. Heat and past overcurrent spikes can permanently shift magnetic core permeability or degrade internal operational amplifiers, leading to inaccurate current feedback, improper drive loop control, and potential IGBT destruction.

What is the difference between an open-loop and a closed-loop current sensor?

Closed-loop (compensated) transducers like the LF 1005-S/SP16 use a secondary winding to generate a opposing magnetic field that balances the primary field. This provides significantly higher accuracy, better linearity, faster response times (< 1 \mus), and near-zero thermal drift compared to basic open-loop sensors.

Can the LF 1005-S/SP16 measure both AC and DC currents?

Yes. The closed-loop Hall effect technology allows measurement of DC, AC, pulsed, and complex distorted current waveforms across a frequency bandwidth from DC up to 150 kHz.

What warranty is included with this New Surplus sensor?

Every New Surplus LEM LF 1005-S/SP16 transducer comes with a standard 12-Month Replacement Warranty. Prior to dispatch, each unit passes rigorous quality control checks, including zero-offset measurement, turns ratio accuracy verification, and dielectric isolation testing.