Description
Key Technical Specifications
| Parameter | Value |
|---|---|
| Model | MTL4850 |
| Manufacturer | Eaton / MTL |
| Product family | MTL4850 HART Multiplexer System |
| Function | Interfaces HART field devices with control, safety, and asset-management systems |
| HART channels | 32 per module |
| Field-loop connections | 64 total; two connections per channel |
| Supported HART devices | HART Rev. 5, 6, and 7 |
| Host interface | RS485, 2-wire multidrop |
| Network capacity | Up to 63 MTL4850 modules; up to 2,016 HART devices per RS485 network |
| RS485 baud rate | 1,200; 9,600; 19,200; or 38,400 baud, auto-detected |
| Module addressing | 8-bit interface, up to 64 addresses |
| HART modem configuration | Single HART modem serving all 32 channels |
| Supply voltage | 19 to 35 V DC |
| Current consumption | 60 mA at 24 V DC ±10% |
| Power dissipation | Less than 1.6 W at 24 V DC ±10% |
| Power protection | Reverse-polarity protected; fused at 375 mA |
| Channel-to-channel isolation | 50 V DC |
| Field-loop isolation | 50 V DC |
| RS485 interface isolation | 25 V DC |
| Operating temperature | −40 to +70°C |
| Storage temperature | −40 to +85°C |
| Relative humidity | 5% to 95%, non-condensing |
| Dimensions | 18 mm × 124 mm × 106.2 mm |
| Weight | 0.125 kg |
| Functional safety | SIL3 capable for connection to safety instrumented functions per IEC 61508 |
| Certifications | ATEX, IECEx, CSA, FM, FMC |
| Mounting environment | Safe area or Zone 2 / Division 2 mounting location |
The MTL4850 uses a single HART modem to service all 32 channels. If your maintenance workflow needs simultaneous HART access to several devices, consider the MTL4854, which provides four HART modems.
Product Introduction
The MTL4850 is an Eaton/MTL 32-channel SIL3 HART multiplexer that connects smart field devices to DCS, PLC, SIS, and HART asset-management software. It provides a two-way HART communications path without disturbing the underlying 4–20 mA analog signal, allowing configuration, calibration, diagnostics, and device monitoring from a single workstation.
It mounts on MTL connection units or backplanes, including systems used alongside MTL4500 intrinsic-safety isolators. Its RS485 multidrop architecture supports up to 63 modules and 2,016 HART devices on one network, making it a practical choice for large process plants and safety-related instrument loops.

MTL4850

MTL4850
Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| Module does not appear on RS485 network | Incorrect RS485 wiring, duplicate address, or termination issue | ✅ High | Verify A/B polarity, module address, termination resistors, and cable shield; check for duplicate addresses | Correct RS485 wiring and set a unique address before replacing the module |
| No LEDs on power-up | 24 V DC supply failure, blown fuse, or reverse polarity | ✅ High | Measure 19–35 V DC at the module supply terminals; inspect the 375 mA fuse and supply polarity | Restore supply or correct polarity before replacing the MTL4850 |
| One HART device cannot communicate | Field loop wiring, HART device fault, or loop loading issue | ❌ Low | Test the device directly with a handheld HART communicator at the field terminals | Troubleshoot the field loop and HART device first |
| Multiple HART devices fail together | MTL4850 module, backplane connection, or RS485 host fault | ✅ High | Check module seating, backplane connectors, and whether the fault follows the module when swapped | Reseat or replace the MTL4850 if the fault follows it |
| HART communication is intermittent | Cable shield, ground loop, excessive RS485 length, or baud-rate mismatch | ✅ Medium | Inspect shield termination and grounding; confirm total RS485 length and baud rate | Correct cable shielding and verify host communication settings |
| Analog 4–20 mA signal is wrong | Transmitter, loop power, IS barrier, or DCS input fault | ❌ Low | Measure loop current directly; the MTL4850 couples to the loop without changing the analog signal | Do not replace the MTL4850 until the analog loop is verified |
| Safety loop diagnostic alarm | Configuration mismatch, loss of communications, or field-device diagnostic event | ✅ High | Review the onboard event log and host-system diagnostics; compare configured and actual device data | Resolve configuration or communications issue; retain event-log evidence |
❗ Do not assume a failed MTL4850 when only one HART device is unreachable. The multiplexer shares one HART modem across 32 channels, but a single bad transmitter, loose loop terminal, or failed IS barrier is more common than a module fault.
If the problem persists after checking power, RS485 wiring, module seating, and field-loop health, contact technical support with photos of the module, backplane, RS485 network, and diagnostic or event logs.
Frequently Asked Questions
Can the MTL4850 be used in a SIL3 safety loop?
Yes. It is certified for use with safety-related subsystems under IEC 61508 and can be connected to instrument loops performing safety functions up to SIL3. Your final SIL calculation must still account for the complete loop, proof-test interval, and application-specific failure data.
How many HART devices can one MTL4850 handle?
One MTL4850 handles 32 HART field devices, using two field-loop connections per channel for 64 total connections. Up to 63 modules can share one RS485 network, supporting up to 2,016 devices.
Does the MTL4850 affect the 4–20 mA analog signal?
No. It couples to each loop through capacitors and provides HART communication without interrupting the analog signal. Verify the loop and IS barrier design during commissioning, but the MTL4850 itself is not intended to regulate or replace the analog measurement path.
Can I connect it directly to a PC?
Not usually by itself. The MTL4850 uses an RS485 2-wire multidrop interface, so you normally use an RS485-to-USB or RS485-to-Ethernet converter to connect it to a PC running HART instrument-management software.
What is the difference between the MTL4850 and MTL4854?
Both provide 32 HART channels, but the MTL4850 has one HART modem while the MTL4854 has four. The MTL4854 is better when you need simultaneous communication with multiple field devices; the MTL4850 is adequate for routine polling and maintenance access.
Can I mount it in a hazardous area?
No. The MTL4850 is designed for safe-area or Zone 2 / Division 2 mounting locations. For intrinsically safe field loops, mount it with compatible MTL4500-series isolators and use the appropriate backplane or connection system.
Why is New Surplus less expensive than factory-new stock?
New Surplus means genuine Eaton/MTL inventory manufactured earlier but not installed or commissioned. We inspect, document, and functionally verify each unit before shipment. It is not used, repaired, or refurbished stock unless clearly stated on the product page.