Description
3. Key Technical Specifications
| Parameter | Value |
|---|---|
| Rated Output Power | 410 W (peak up to 470 W short duration) |
| Input Voltage | 100-240 VAC, 8 A |
| Input Frequency | 50-60 Hz |
| +5 V Output | 26 A max |
| +3.3 V Output | 24 A max |
| +12 V1 Output | 15 A max (18 A peak 10 s) |
| +12 V2 Output | 15 A max (18 A peak 10 s) |
| -12 V Output | 0.5 A max |
| +5 V Auxiliary | 2 A max |
| Form Factor | ATX |
| Typical Dimensions | Approx. 150 × 140 × 86 mm |
| Cooling | Internal fan (80 mm or 120 mm depending on revision) |
| Common Connectors | 20+4-pin ATX, 4+4-pin EPS, Molex, SATA, Floppy |
| Typical Application | Siemens medical systems, Fujitsu Celsius M460, industrial PCs |
4. Product Introduction
The Newton NPS-400AB is a 410 W ATX form-factor switching power supply designed for industrial and medical computing platforms. It delivers regulated multi-rail DC outputs with dual independent +12 V rails and supports universal 100-240 VAC input.
This unit is the direct OEM replacement under Siemens part number S26113-E503-V50 and is commonly used in Siemens Axiom imaging systems and Fujitsu Celsius workstations. Its dual +12 V architecture and industrial-grade construction make it suitable for continuous-duty environments where standard consumer ATX supplies fall short.

NPS-400AB

NPS-400AB
5. Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| No power / system dead | Input voltage or fuse failure | ✅ High | Measure AC at inlet; check internal fuse if accessible | Confirm 100-240 VAC present before replacing unit |
| Fans spin but no POST | Missing or weak +5 V / +3.3 V | ✅ High | Measure +5 V and +3.3 V at ATX connector under load | Replace if rails are out of ATX tolerance |
| Intermittent shutdown under load | Over-current on +12 V rails | ✅ High | Monitor +12 V1 and +12 V2 voltage and current draw | Verify total load stays within 15 A per rail |
| Fan noisy or stopped | Bearing wear or dust blockage | ✅ Medium | Observe fan operation and clean intake | Replace supply if fan fails; do not run without cooling |
| Only one rail present | Internal rail failure | ✅ High | Check all DC rails with multimeter at connectors | Unit is not field-repairable; replace complete PSU |
| System works with known-good PSU | Motherboard or peripheral short | ❌ Low | Swap with verified working power supply | Do not condemn the NPS-400AB until external load is ruled out |
If the unit still fails after these checks, record exact voltage readings on all rails, note any error LEDs or beeps from the host system, and contact technical support with the serial number and revision marking (e.g., Rev 05).
6. Frequently Asked Questions (FAQ)
Q: Is the NPS-400AB the same as Siemens S26113-E503-V50?
Yes. S26113-E503-V50 is the Siemens part number for the Newton NPS-400AB / NPS-400AB B. Functionally identical units carry either marking.
Q: Can I use a standard consumer 500 W ATX supply as a drop-in replacement?
Not recommended. The NPS-400AB has dual independent +12 V rails and specific current ratings matched to the original industrial motherboard. A generic single-rail consumer supply may trip protection or deliver unstable voltage under the same load profile.
Q: What is the difference between NPS-400AB and NPS-400AB B?
The “B” suffix typically indicates a later revision (commonly Rev 05). Electrical specifications remain the same; connector pinouts and mechanical fit are identical for the systems that use this part.
Q: Does this supply support active PFC?
Most revisions of the NPS-400AB include passive or basic power-factor correction suitable for industrial environments. It is not a high-efficiency 80 PLUS Gold consumer unit.
Q: Can the fan be replaced in the field?
No. The fan is internal and the supply is not designed for component-level service. Replace the complete unit if the fan fails.
Q: Why is surplus pricing lower than current OEM list?
These are new original or new-surplus units that have never been installed in a system. They are tested for full output under load and carry a standard warranty. OEM lead times for medical-grade spares can be long; ready stock eliminates that delay.
Q: Is this power supply still in active production?
Newton no longer lists the NPS-400AB as a current catalog item. Availability is limited to remaining new surplus and carefully tested used stock. Verify exact revision and connector set against your system before ordering.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626