Sale!

NI-9853 2-Port High-Speed C Series CAN Module

  • Model: NI-9853 (779429-01 / 780178-01 conformal coat)
  • Brand: National Instruments (NI)
  • Series: C Series
  • Core Function: Dual-port high-speed CAN interface for FPGA control
  • Product Type: CAN Interface Module
  • Key Specs: 2 independent ports, 1 Mbps max, ISO 11898, -40 °C to 70 °C
  • Condition: New Original / New Surplus
Categories: , , , , SKU: 9853 Brand:

Description

3. Key Technical Specifications

Parameter Value
Number of Ports 2 (independent, isolated)
Physical Layer High-Speed CAN (ISO 11898)
Transceiver Philips TJA1041
Controller Philips SJA1000 (CAN 2.0B)
Identifier Support 11-bit and 29-bit
Maximum Baud Rate 1 Mbps
CAN0 Power Internally powered (no external Vsup)
CAN1 Supply Voltage (Vsup) +8 V DC to +25 V DC
Bus Voltage Range (CAN_H/CAN_L) -27 V DC to +40 V DC
Isolation (port-to-port / port-to-earth) 60 V DC continuous (Measurement Category I)
Operating Temperature -40 °C to 70 °C
Chassis Power (Active Transmit) 625 mW max
Chassis Power (Active Receive) 400 mW max
Weight Approx. 144 g (5.0 oz)
Connectors 2 × 9-pin male D-Sub
Compatible Platform CompactRIO only (LabVIEW FPGA / NI-RIO)

4. Product Introduction

The NI-9853 is a 2-port high-speed C Series CAN interface module built for CompactRIO systems. Each port runs an independent Philips SJA1000 controller with TJA1041 transceiver, supporting full CAN 2.0B frames at up to 1 Mbps for FPGA-level frame control and triggering.

Engineers choose it when they need direct byte-level CAN access inside the LabVIEW FPGA Module rather than higher-level XNET drivers. The two ports are galvanically isolated from each other and from the chassis, with CAN0 self-powered and CAN1 requiring external bus power.

5. Troubleshooting Quick Reference

Symptom Possible Cause Relevance to this Part Quick Check Method Recommendation
No activity on CAN1 Missing external Vsup ✅ High Measure voltage at pin 9 (Vsup) of CAN1 connector Supply +8 V to +25 V DC; CAN0 does not need this
Both ports silent Module not recognized / FPGA code issue ✅ High Check module detection in LabVIEW project and FPGA I/O nodes Confirm NI-RIO driver and CompactRIO compatibility
Bus errors / error frames Missing or wrong termination ✅ Medium Verify 120 Ω termination at both ends of the bus Add proper terminators; check cable impedance
Intermittent communication Baud rate mismatch or bit timing ✅ High Compare BTR0/BTR1 settings against other nodes Match exact bit timing; do not rely on auto-baud
Module power LED off Chassis power or slot issue ❌ Low Measure chassis power rails and try different slot Check CompactRIO power budget before swapping module
One port works, other does not Port isolation or wiring fault ✅ Medium Swap cables between ports; measure continuity Confirm pinout (CAN_H pin 7, CAN_L pin 2)

If the module still fails after these checks, capture the FPGA diagnostic buffer, take clear photos of the connectors and LED status, and contact technical support with the serial number and firmware details.

9853

9853

9853

9853

6. Frequently Asked Questions (FAQ)

Q: Can I use the NI-9853 in a CompactDAQ chassis?
No. The NI-9853 is designed only for CompactRIO systems running LabVIEW FPGA and the NI-RIO driver. It will not function in CompactDAQ.

Q: Does CAN0 really need no external power?
Correct. CAN0 is powered from the CompactRIO backplane. CAN1 requires +8 V to +25 V DC on the Vsup pin (usually supplied by the CAN bus itself). Connecting a powered bus to CAN0 will not damage it.

Q: Is the NI-9853 hot-swappable?
No. Always power down the CompactRIO chassis before inserting or removing the module. Hot-swapping can damage the backplane or the module.

Q: What is the difference between part numbers 779429-01 and 780178-01?
779429-01 is the standard enclosed version. 780178-01 adds conformal coating for higher humidity or condensation environments. Functionally they are identical.

Q: Can I replace an older NI-CAN or XNET module with the NI-9853?
Only if the application is written for LabVIEW FPGA on CompactRIO. The NI-9853 uses the older NI-985x FPGA interface, not NI-XNET. Frame handling is at the byte level inside the FPGA, not through the XNET API.

Q: Why is surplus or new-old-stock pricing lower than current NI list price?
These units are new original stock that has not been previously installed. They carry full functional testing and a standard warranty. Lead times from NI can run 8–9 weeks; ready stock eliminates that delay.

Q: Do I need special software beyond LabVIEW FPGA?
Yes. Install the latest CompactRIO and NI-RIO software that supports the NI-9853. The module does not support Scan Mode or Single-Cycle Timed Loop.