Description
Core Product Summary (Brand / Model / Key Attributes)
The National Instruments PXI-4472B is an 8-channel dynamic signal acquisition (DSA) module engineered for high-precision sound, vibration, and acoustic measurements. Designed for integration into PXI and CompactPCI chassis architectures, it provides simultaneous analog input sampling across all channels to support advanced multi-sensor testing, modal analysis, and rotating machinery diagnostics.
The module incorporates 24-bit analog-to-digital converters (ADCs), delivering a dynamic range of up to 110 dB with a maximum sampling rate of 102.4 kS/s per channel. It features software-selectable AC/DC coupling, integrated IEPE (Integrated Electronic Piezoelectric) signal conditioning for accelerometers and microphones, and precise phase-matching across channels. Housed in a standard 3U PXI slot format, the PXI-4472B provides high-accuracy time- and frequency-domain analysis for automated test equipment (ATE) and laboratory testing environments.
Key Technical Specifications
| Parameter | Verified Specification Value |
| Manufacturer | National Instruments (NI) |
| Model / Part Number | PXI-4472B |
| Product Type | Dynamic Signal Acquisition (DSA) / Sound and Vibration Module |
| Form Factor | 3U PXI / CompactPCI module (2 slots wide or standard 1-slot depending on backplane configuration) |
| Analog Input Channels | 8 simultaneous sampling channels |
| ADC Resolution | 24-bit delta-sigma ADCs |
| Maximum Sampling Rate | Up to 102.4 kS/s per channel |
| Dynamic Range | 110 dB (typical) |
| Frequency Range | DC to 45 kHz (approximate usable bandwidth) |
| Signal Conditioning | Software-selectable IEPE excitation (4 mA constant current source), AC/DC coupling |
| Input Coupling Options | AC, DC, GND |
| Maximum Input Voltage Range | \pm 10 V peak |
| Bus Interface | PXI backplane (32-bit, 33 MHz PCI bus) |
Detailed Product Overview
The National Instruments PXI-4472B functions as a high-fidelity measurement front-end for applications requiring strict phase alignment and low noise floors. By digitizing signals concurrently across all 8 input channels using 24-bit delta-sigma converters, it eliminates phase delay errors between channels, making it well-suited for structural dynamics, noise, vibration, and harshness (NVH) testing.
The module includes built-in anti-aliasing filters that automatically adjust with the sampling rate to reject out-of-band signals. Its flexible IEPE signal conditioning supplies power directly to connected accelerometers, microphones, and force transducers over standard coaxial cabling, reducing external conditioning hardware requirements. Integration into a PXI system controller enables real-time data streaming and analysis via software environments such as NI LabVIEW, LabWindows/CVI, and DIAdem.

PXI-4472B

PXI-4472B
Engineering Selection Highlights
- Simultaneous 8-Channel Sampling: Digitizes input data across all channels at identical instances to preserve phase relationships in multi-axis vibration analysis.
- High Dynamic Range (110 dB): Resolves low-amplitude signal variations in the presence of large background noise, ensuring accurate acoustic and seismic measurements.
- Built-In IEPE Conditioning: Simplifies sensor hookup by providing a direct 4 mA constant current excitation source for piezoelectric transducers.
- Flexible Anti-Aliasing Filters: Automatically scales digital and analog filter cutoffs relative to the configured sample rate to prevent signal corruption.
- PXI Synchronization: Leverages PXI backplane trigger lines to synchronize sampling across multiple modules in multi-channel test configurations.
Dimensions, Mounting & Connection Notes
The PXI-4472B is housed in a standard 3U-height PXI module enclosure. It slides directly into an available peripheral slot of a PXI chassis and secures via top and bottom panel screws to ensure solid chassis grounding.
All 8 analog input signals connect via front-panel BNC receptacles. When deploying the module in high-vibration test cells or industrial environments, ensure that input cables are strain-relieved to prevent mechanical stress on the front panel connectors and maintain low-noise signal integrity.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Chassis Compatibility | PXI or PXI Express (Hybrid) chassis | Must be installed in a standard PXI peripheral slot with bus master capability. |
| Controller Requirement | Embedded PXI controller or MXI-connected remote PC | Requires NI-DAQmx driver software and compatible application development environments. |
| Cabling & Connectors | Front-panel BNC connectors | Requires shielded BNC cables to minimize electromagnetic interference on sensitive low-level analog inputs. |
| Software Environment | NI-DAQmx driver, LabVIEW, C/C++, or Python | Software toolkits must support DAQmx data acquisition functions. |
FAQ
What is the primary application of the NI PXI-4472B?
The PXI-4472B is designed for dynamic signal acquisition, specializing in acoustic testing, structural vibration analysis, and rotating machinery diagnostics.
How many simultaneous channels does the module support?
The module features 8 simultaneous sampling input channels.
Does the PXI-4472B support IEPE sensors?
Yes, it includes software-selectable IEPE signal conditioning (4 mA constant current excitation) to power compatible accelerometers and microphones directly.
What is the resolution of the analog-to-digital converters?
The unit utilizes 24-bit delta-sigma ADCs to deliver high amplitude resolution and a dynamic range of up to 110 dB.
What software drivers are required to operate the module?
The module operates using the standard NI-DAQmx driver software suite across supported programming environments like LabVIEW.
Verification & Troubleshooting Notes
- IEPE Open/Short Diagnostics: If an accelerometer or microphone signal reads flatline or clips unexpectedly, check the NI-DAQmx channel properties to verify whether IEPE excitation current is correctly enabled or if sensor cabling is faulted.
- Noise and Grounding Checks: If unexpected AC line hum appears in spectral measurements, verify that the PXI chassis is properly earth-grounded and that signal cable shields are intact to reject ground loops.
- Sample Rate and Aliasing: Ensure that the configured software sampling rate corresponds appropriately to the frequency content of the physical phenomenon being measured to prevent aliasing errors.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626