Description
Core Product Summary
The National Instruments PXI-6123 is a 3U PXI multifunction data-acquisition module with eight differential, simultaneously sampled analog-input channels. Each channel uses an independent 16-bit ADC and supports a maximum sampling rate of 500 kS/s per channel.
The module also provides eight TTL/CMOS digital I/O lines, two 24-bit counter/timers, analog and digital triggering, and a 68-pin SCSI-II I/O connector. It is available with 16 MS or 32 MS onboard analog-input memory, depending on the part-number configuration. NI-DAQmx provides the software interface for configuration, acquisition, digital I/O, and timing operations.
Key Technical Specifications
| Attribute | Specification |
|---|---|
| Manufacturer | National Instruments (NI) |
| Model | PXI-6123 |
| Product type | Simultaneous-sampling multifunction DAQ module |
| Form factor | 3U PXI module |
| Analog-input channels | 8 differential |
| ADC architecture | One 16-bit ADC per channel; simultaneous sampling |
| Resolution | 16 bits |
| Maximum sampling rate | 500 kS/s per channel |
| Minimum sampling rate | No minimum |
| Input ranges | ±1.25 V, ±2.5 V, ±5 V, ±10 V |
| Input coupling | DC |
| Input impedance | 100 MΩ in parallel with 10 pF, AI+ to AI GND and AI− to AI GND |
| Input bias current | ±2 pA typical, ±25 pA maximum |
| Maximum working voltage | ±11 V on AI+ and AI− for all ranges, Measurement Category I |
| Overvoltage protection | ±36 V on AI+ and AI− |
| Onboard input FIFO | 16 MS or 32 MS, depending on part number |
| INL | ±2 LSB maximum |
| DNL | −1 LSB minimum, +1.5 LSB maximum, no missing codes |
| Digital I/O | 8 bidirectional TTL/CMOS lines |
| Digital transfer rate | 10 Mwords/s, where one word is 8 bits |
| Counter/timers | 2 up/down counter/timers, 24-bit resolution |
| Frequency scaler | 1 channel, 4-bit resolution |
| Counter base clocks | 20 MHz and 100 kHz |
| Counter maximum source frequency | 20 MHz |
| Analog trigger source | All analog-input channels |
| Digital trigger compatibility | TTL, rising or falling edge |
| PXI trigger lines | PXI_Trig<0..6> |
| PXI star trigger | 1 |
| I/O connector | 68-pin male SCSI-II |
| Dimensions | 16.0 × 10.0 cm (6.3 × 3.9 in.), excluding connectors |
| Operating temperature | 0 °C to 50 °C |
| Storage temperature | −20 °C to 70 °C |
| Operating humidity | 10% to 90% RH, noncondensing |
| Maximum altitude | 2,000 m |
| Software | NI-DAQmx |
Engineering Selection Highlights
- The PXI-6123 provides eight differential analog inputs with one ADC per channel, so all channels can be sampled simultaneously rather than through a multiplexed input architecture.
- Its 500 kS/s per-channel rate defines the acquisition speed for each channel; the rate is not divided among channels.
- The module supports four input ranges from ±1.25 V to ±10 V, allowing resolution and input protection to be matched to signal amplitude.
- The 16 MS or 32 MS onboard FIFO enables buffered acquisition and is selected by the exact part-number configuration.
- The 68-pin SCSI-II connector requires a compatible DAQ cable and terminal accessory; the connector carries analog inputs, digital I/O, timing, and power terminals.
- The module includes two 24-bit counter/timers, digital triggering, PXI trigger lines, and a PXI star-trigger input, supporting event counting, pulse timing, and coordinated PXI acquisitions.
- Its Measurement Category I rating and ±11 V maximum working voltage establish the signal-conditioning boundary; higher-voltage signals require external isolation or attenuation.

PXI-6123

PXI-6123
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Chassis format | 3U PXI chassis | The module is a PXI multifunction I/O module and uses the PXI bus interface. |
| Analog inputs | Eight differential channels, AI<0..7> | Differential connections require AI+ and AI− pairs referenced to AI GND. |
| Digital I/O | P0.<0..7>, TTL/CMOS | Lines power up as high-impedance inputs. |
| Timing and triggering | PFI 0–9, CTR 0/1, FREQ OUT, PXI trigger bus | PFI terminals provide flexible routing for triggers, clocks, counter sources, gates, and outputs. |
| PXI synchronization | PXI_Trig<0..6> and star trigger | The module can use PXI trigger lines and a star trigger for multi-module coordination. |
| I/O connection | 68-pin male SCSI-II connector | Use a compatible 68-pin DAQ cable and terminal block or connector accessory. |
| Software | NI-DAQmx | NI-DAQmx configures and programs analog input, digital I/O, counters, and triggering. |
| Data transfer | DMA, interrupts, or programmed I/O | DMA supports scatter-gather transfers for acquisition and digital operations. |
| Cabling | Shielded cabling | Shielded cabling is required for the stated EMC compliance. |
Dimensions, Mounting & Connection Notes
The PXI-6123 is a 3U PXI module measuring 16.0 cm high by 10.0 cm deep, excluding connectors. It installs in a 3U PXI chassis and connects to external signals through a 68-pin male SCSI-II connector.
The module requires 1.9 A at +5 VDC, 1.55 A at +3.3 VDC, and 81 mA at −12 VDC. The I/O connector can supply +4.65 to +5.25 VDC at up to 1 A for compatible external circuitry.
The analog-input terminals are rated for Measurement Category I use only and must not be used for Measurement Category II, III, or IV measurements. The AI+ and AI− terminals have a maximum working voltage of ±11 V for all ranges and ±36 V overvoltage protection. The module is specified for indoor use at Pollution Degree 2, up to 2,000 m altitude.
Applications & System Role
The PXI-6123 functions as a high-resolution, simultaneous-sampling acquisition and timing module within a PXI-based test or measurement system. Its eight independent ADCs make it suitable when relative timing among multiple voltage signals matters, such as multi-channel transient capture, frequency-domain measurements, and synchronized signal comparison.
NI identifies IF digitization, transient recording, telecom manufacturing test for ISDN, ADSL, and POTS, ultrasound and sonar testing, and high-energy physics as application contexts for the PXI-6123. Its differential inputs, 16-bit resolution, 500 kS/s per-channel rate, and large onboard memory support these signal-acquisition roles.
The digital I/O, counter/timers, and trigger routing extend the module beyond voltage acquisition. It can coordinate acquisitions with external events, generate timing signals, count pulses, and participate in PXI-based multi-instrument synchronization.
FAQ
What is the NI PXI-6123?
The NI PXI-6123 is a 3U PXI simultaneous-sampling multifunction data-acquisition module with eight differential 16-bit analog inputs, eight digital I/O lines, and two 24-bit counter/timers.
How many analog-input channels does the PXI-6123 have?
It has eight differential analog-input channels, AI<0..7>.
What is the maximum sampling rate?
The maximum sampling rate is 500 kS/s per channel.
Does the PXI-6123 sample channels simultaneously?
Yes. It uses one 16-bit ADC per channel, allowing all eight analog inputs to be sampled simultaneously.
What input voltage ranges are supported?
The module supports ±1.25 V, ±2.5 V, ±5 V, and ±10 V input ranges.
How much onboard memory does it have?
The PXI-6123 is available with either 16 MS or 32 MS of onboard analog-input FIFO memory, depending on the part-number configuration.
What type of connector does the PXI-6123 use?
It uses a 68-pin male SCSI-II I/O connector.
What software is used to program the PXI-6123?
NI-DAQmx is the software driver and configuration utility used to program and operate the module.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626