Description
Core Product Summary
The National Instruments PXI-6713 is a 3U PXI analog-output module with eight 12-bit voltage-output channels. It is designed for simultaneous multichannel updates in control, stimulus-response, power-supply control, deterministic control, and sensor or signal-simulation applications.
The module supports up to 1 MS/s per channel using its onboard FIFO and provides a ±10 V output range or an external-reference range. It also includes eight 5 V TTL/CMOS digital I/O lines, two 24-bit counter/timers, digital triggering, external clocking, and a 68-pin SCSI-II I/O connector. NI-DAQmx provides the software interface for waveform generation, digital I/O, counter/timer configuration, and triggering.
Key Technical Specifications
| Attribute | Specification |
|---|---|
| Manufacturer | National Instruments (NI) |
| Model | PXI-6713 |
| Product type | PXI analog-output module |
| Form factor | 3U PXI/CompactPCI module |
| Analog-output channels | 8 voltage outputs |
| DAC type | Double-buffered, multiplying |
| Resolution | 12 bits, 1 in 4,096 |
| Maximum update rate | 1 MS/s per channel using local FIFO; 1,000 kS/s for 1–5 active channels |
| Update rate, 6 active channels | 952 kS/s using local FIFO |
| Update rate, 7 active channels | 833 kS/s using local FIFO |
| Update rate, 8 active channels | 740 kS/s using local FIFO |
| Local FIFO buffer | 16,384 samples |
| DMA channels | 3 |
| Data transfer modes | DMA, interrupts, programmed I/O |
| DMA mode | Scatter-gather |
| Output ranges | ±10 V or ±EXT REF |
| Output coupling | DC |
| Output impedance | 0.1 Ω maximum |
| Current drive | ±5 mA maximum |
| Output stability | Any passive load up to 1,500 pF |
| Output protection | Short circuit to ground |
| Power-on output state | 0 V, ±200 mV |
| Slew rate | 20 V/µs |
| Settling time | 3.0 µs to ±0.5 LSB accuracy |
| Channel crosstalk | −70 dB with SH68-68-EP cable under stated test conditions |
| Total harmonic distortion | −80 dB typical under stated sine-wave test condition |
| External reference input range | ±11 V |
| External reference overvoltage protection | ±25 V powered on; ±15 V powered off |
| External reference input impedance | 10 kΩ |
| Digital I/O | 8 bidirectional 5 V TTL/CMOS lines |
| Digital power-on state | Input, high impedance |
| Counter/timers | 2 up/down counter/timers, 24-bit resolution |
| Frequency scaler | 1 channel, 4-bit resolution |
| Counter base clocks | 20 MHz and 100 kHz |
| Counter maximum source frequency | 20 MHz |
| PXI trigger lines | PXI_Trig<0..5> |
| PXI star trigger | 1 |
| PXI clock | 1 |
| I/O connector | 68-pin male SCSI-II |
| Dimensions | 16 × 10 cm (6.3 × 3.9 in.), excluding connectors |
| Power requirement | +5 VDC, 1.25 A typical, 1.5 A maximum |
| Operating temperature | 0 °C to 50 °C |
| Storage temperature | −20 °C to 70 °C |
| Operating humidity | 5% to 90% RH, noncondensing |
| Maximum altitude | 2,000 m |
| Software | NI-DAQmx |
Engineering Selection Highlights
- The PXI-6713 provides eight voltage-output channels, making it suitable when several analog stimulus or control signals must be updated from one PXI module.
- Its 12-bit resolution provides 4,096 output codes; verify that this resolution meets the required control granularity or waveform fidelity.
- The 1 MS/s per-channel update rate applies when using the local FIFO; the effective rate decreases to 740 kS/s when all eight channels are active.
- The 16,384-sample FIFO supports continuous waveform generation and reduces dependence on continuous host-PC data streaming.
- The module supports ±10 V or external-reference output ranges; the external-reference path accepts a ±11 V input and uses a 10 kΩ input impedance.
- Its ±5 mA current-drive limit means the module is intended for voltage-output applications; loads requiring more current need external amplification or a power-output module.
- PXI trigger lines, a star trigger, digital triggering, and two counter/timers support deterministic starts, clocking, and coordination with other PXI modules.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Chassis format | 3U PXI or CompactPCI chassis | The module operates as a PXI/CompactPCI master or slave. |
| Analog outputs | AO<0..7>, referenced to AO GND | Eight separate voltage outputs are available on the 68-pin connector. |
| Output range | ±10 V or ±EXT REF | Use the internal ±10 V range or configure the output scaling through the external-reference input. |
| External reference | AO EXT REF terminal | The external reference input is always a 1.414 V peak-to-peak sine wave for the NI 6711/6713 architecture. |
| Digital I/O | P0.<0..7>, 5 V TTL/CMOS | Lines power up as high-impedance inputs and use programmed I/O transfers. |
| Timing and triggering | PFI 0–9, CTR 0/1, FREQ OUT, EXT STROBE | PFI terminals support analog-output start triggers, sample clocks, counter sources/gates, and other timing functions. |
| PXI synchronization | PXI_Trig<0..5>, star trigger, PXI clock | These resources support coordinated operation with other PXI modules. |
| I/O connection | 68-pin male SCSI-II connector | Use a compatible 68-pin DAQ cable and terminal accessory. |
| Software | NI-DAQmx | NI-DAQmx is the driver and configuration utility for the module. |
| Cabling | Shielded cabling | Shielded cabling is required for the stated EMC performance. |
Dimensions, Mounting & Connection Notes
The PXI-6713 is a 3U PXI/CompactPCI module measuring 16 cm high by 10 cm deep, excluding connectors. It installs in a 3U PXI chassis and uses a 68-pin male SCSI-II I/O connector.
The module requires 1.25 A typical or 1.5 A maximum at +5 VDC. The I/O connector can supply +4.65 to +5.25 VDC at up to 1 A for compatible external circuitry.
Analog outputs are designated AO<0..7> and share AO GND terminals. The AO EXT REF terminal accepts the external reference signal. Digital lines P0.<0..7>, timing terminals PFI 0 through PFI 9, counter outputs, and FREQ OUT are also routed through the same 68-pin connector.
The module is intended for indoor use at Pollution Degree 2 and altitudes up to 2,000 m. Its maximum channel-to-earth working voltage is ±11 V, and its maximum channel-to-channel working voltage is ±22 V, both under Installation Category I.

PXI-6713

PXI-6713
Detailed Product Overview
The NI PXI-6713 is an eight-channel, 12-bit analog-output module for PXI and CompactPCI systems. It is intended for applications that require multiple voltage outputs to be updated together, including control loops, test stimulus, power-supply control, and simulated sensor signals.
Each channel uses a double-buffered, multiplying DAC and supports a nominal ±10 V output range. The module can also operate with an external reference through the AO EXT REF input. The external-reference input accepts ±11 V, has 10 kΩ input impedance, and is protected to ±25 V when the module is powered on and ±15 V when powered off. This architecture allows the output scaling to follow a supplied reference signal under the documented conditions.
Update performance depends on the number of active channels and the data source. Using the 16,384-sample local FIFO, the PXI-6713 supports 1,000 kS/s for one through five active channels, 952 kS/s for six channels, 833 kS/s for seven channels, and 740 kS/s for eight channels. These figures account for the time required to reset the FIFO when cycling through it. When generating waveforms from host-PC memory, the documented rates are 1,000 kS/s for one through eight channels, although those results were measured on a specific PCI-6713 host configuration and can vary with system load.
The analog output has a maximum output impedance of 0.1 Ω and can source or sink up to ±5 mA. It is stable with any passive load up to 1,500 pF and is protected against a short circuit to ground. After calibration, the module specifies ±0.5 LSB maximum relative accuracy, ±1.0 LSB maximum differential nonlinearity, and guaranteed 12-bit monotonicity. The specified settling time is 3.0 µs to ±0.5 LSB accuracy, and the slew rate is 20 V/µs.
Digital and timing resources extend the module’s role beyond waveform generation. Eight 5 V TTL/CMOS bidirectional lines support digital control and status signals. Two 24-bit counter/timers, one 4-bit frequency scaler, and PFI terminals support event counting, frequency division, pulse generation, external clocking, and triggering. The PXI-6713 provides six PXI trigger lines, one star-trigger input, and one PXI clock connection.
The module uses NI-DAQmx for configuration and operation. It supports DMA, interrupt, and programmed-I/O transfers, with scatter-gather DMA available for analog-output operations. For EMC compliance, NI specifies shielded cabling. The module is designed to meet IEC 61010-1, EN 61010-1, UL 61010-1, and CSA 61010-1 safety-standard requirements, and to meet the listed EMC standards for measurement, control, and laboratory-use equipment.
Applications & System Role
The PXI-6713 serves as the analog-stimulus and control-output stage in a PXI-based automated test or control system. Its eight channels can generate independent or coordinated voltage waveforms for device excitation, actuator control, sensor simulation, and closed-loop control experiments.
NI identifies stimulus-response testing, power-supply control, high-speed deterministic control, and sensor or signal simulation as application contexts. The module can also replace stand-alone PID controllers, low-speed arbitrary waveform generators, and function generators where its output range, update rate, and current-drive capability match the application.
Each output data point can be controlled individually, allowing generation of square, sine, sawtooth, and more complex waveforms. The onboard FIFO, DMA support, external clocking, and PXI trigger resources make the module suitable for deterministic waveform playback and synchronized multichannel output.
FAQ
What is the NI PXI-6713?
The NI PXI-6713 is a 3U PXI analog-output module with eight 12-bit voltage-output channels, eight digital I/O lines, and two 24-bit counter/timers.
How many analog-output channels does the PXI-6713 have?
It has eight voltage-output channels, AO<0..7>.
What is the maximum update rate?
The maximum update rate is 1 MS/s per channel when using the local FIFO. With all eight channels active, the rate is 740 kS/s.
What is the output voltage range?
The module provides a ±10 V output range or an external-reference output range.
How much current can each output drive?
Each analog output can source or sink up to ±5 mA.
What type of connector does the PXI-6713 use?
It uses a 68-pin male SCSI-II I/O connector.
What digital and timing features does it include?
It includes eight 5 V TTL/CMOS digital I/O lines, two 24-bit counter/timers, one 4-bit frequency scaler, PFI timing terminals, digital triggering, external clocking, PXI trigger lines, and a PXI star trigger.
What software controls the PXI-6713?
NI-DAQmx is the software driver and configuration utility used to program and operate the module.

WhatsApp: +86 16626708626
Email: