Description
Core Product Summary
The NI PXIe-4142 is a four-channel source measure unit designed for automated electrical characterization and semiconductor or electronic-device testing. Each channel supports voltage sourcing and measurement up to ±24 V and current up to ±150 mA, with four-quadrant operation and integrated remote 4-wire sensing. The module uses the PXI Express interface and provides a high-speed sequencing engine for coordinating test operations with other compatible instruments. NI lists the module under part number 782430-01.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | National Instruments (NI) |
| Model | PXIe-4142 |
| Part number | 782430-01 |
| Instrument type | Source Measure Unit (SMU) |
| Number of channels | 4 |
| Voltage range | −24 V to +24 V |
| DC current range | −150 mA to +150 mA |
| Maximum DC source power | 3.6 W per channel, as listed by NI |
| Maximum DC sink power | 3.6 W per channel, as listed by NI |
| Operating mode | Four-quadrant source and sink operation |
| Remote sensing | Integrated 4-wire remote sensing |
| Maximum continuous sample rate | 600,000 samples/s per channel |
| Maximum source update rate | 100,000 updates/s per channel |
| Host interface | PXI Express |
| Front-panel connector | 25-position male D-SUB |
| Module format | 3U, single-slot PXI Express |
| Dimensions | 2.0 × 13.0 × 21.6 cm (0.8 × 5.1 × 8.5 in.) |
| Weight | 412 g (14.53 oz) |
| Calibration interval | 1 year recommended |
Specifications are based on NI product information and the PXIe-4142 specification document. Confirm the applicable limits and operating conditions in the official manual before designing a test system.
Detailed Product Overview
The NI PXIe-4142 combines programmable power sourcing and electrical measurement in one PXI Express module. Rather than requiring separate instruments for every source and measurement step, engineers can use its four SMU channels to apply controlled electrical signals and measure device response within an automated test sequence.
Its ±24 V voltage range and ±150 mA current range make it suitable for characterizing electronic components and devices that operate within those limits. Four-quadrant operation allows the instrument to source or sink power according to the electrical conditions of the device under test (DUT).
Integrated remote sensing supports four-wire measurements, helping compensate for voltage drops in test leads. This is particularly relevant when connection resistance could affect the voltage delivered to the DUT or the accuracy of the resulting characterization.
The module also includes a high-speed sequencing engine. Engineers can coordinate source and measurement operations and synchronize test events with compatible PXI instruments, including switching or digital test modules. This supports repeatable, automated test workflows without requiring every operation to be initiated individually by the host application.

PXIe-4142

PXIe-4142
Key Features and Engineering Advantages
- Four independent SMU channels: Consolidates multiple source-and-measure functions in a single PXI Express module for multi-point testing.
- Four-quadrant operation: Supports both sourcing and sinking behavior within the specified voltage, current, and power limits.
- Remote 4-wire sensing: Helps account for voltage drops across test leads when making voltage measurements or controlling the voltage at the DUT.
- High-speed measurement: Supports continuous sampling rates up to 600 kS/s per channel, subject to the specified acquisition conditions.
- Sequenced test execution: Enables programmed source and measurement sequences for repeatable device characterization.
- PXI Express integration: Fits into a compatible modular test chassis and can be synchronized with other instruments in an automated test system.
System Compatibility and Integration Requirements
The PXIe-4142 is intended for use in a compatible PXI Express test system. Before installation or replacement, verify the following:
- Chassis compatibility: Confirm that the chassis supports PXI Express modules and provides the required slot and power resources.
- Software and drivers: NI lists a dedicated driver download and documentation for the PXIe-4142. Check the supported NI-DCPower driver version and your development environment before deployment.
- Terminal connections: The module uses a 25-position male D-SUB front-panel connector. Verify the terminal block, wiring arrangement, and signal assignments before connecting the DUT.
- Measurement configuration: Select appropriate source ranges, current limits, sensing mode, and transient-response settings for the device under test.
- Channel grounding: The specification document states that the channels are isolated from earth ground but share a common low terminal. Do not assume that all four channels are independently isolated from one another.
- Thermal management: Maintain the chassis airflow required by NI. The calibration procedure specifically calls for high fan speed, clean fan filters where fitted, and filler panels in unused slots during calibration testing.
Dimensions, Mounting, and Connection Notes
The PXIe-4142 is a 3U, single-slot PXI Express module measuring approximately 20 × 130 × 216 mm. Its front-panel interface is a 25-position male D-SUB connector.
When planning a rack or test fixture, allow for chassis cooling and access to the front-panel wiring. Select the correct mating terminal block and follow the NI pinout documentation rather than relying on connector appearance alone. Confirm the complete mechanical and electrical requirements in the product manual before installation.
Frequently Asked Questions
What is the NI PXIe-4142 used for?
It is used for automated electrical testing and device characterization, where a system must apply controlled voltage or current and measure the resulting electrical response.
How many channels does the PXIe-4142 provide?
It provides four source measure channels.
What are its voltage and current ranges?
NI lists a voltage range of −24 V to +24 V and a DC current range of −150 mA to +150 mA. The actual usable operating point depends on the instrument’s power limits and other specified conditions.
Does the PXIe-4142 support four-wire sensing?
Yes. Each channel includes integrated remote 4-wire sensing, which can help compensate for voltage drops in test leads.
Can the PXIe-4142 synchronize with other test instruments?
Yes. Its sequencing engine supports synchronization with compatible PXI instruments. The specific trigger routing and timing behavior should be checked against the instrument specifications and software configuration.
What should be checked before purchasing a replacement?
Confirm the exact model and part number, PXI Express chassis compatibility, connector and terminal-block requirements, driver support, calibration status, and the intended test ranges. Also verify the module’s grounding arrangement and power limits against the existing test application.
Documented Performance Data
The following figures provide useful reference points when assessing the PXIe-4142 for a test application:
- Maximum continuous sample rate: 600 kS/s per channel.
- Maximum source update rate: 100,000 updates/s per channel.
- Maximum voltage range: ±24 V.
- Maximum DC current range: ±150 mA.
- Recommended calibration interval: one year.
These are specified limits or recommendations, not guarantees that every test sequence will achieve the maximum rate or accuracy. Actual performance depends on configuration, load, measurement settings, wiring, and environmental conditions. Consult the full NI specifications for accuracy, resolution, settling time, and transient response before establishing test acceptance criteria.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626