Description
Core Product Summary
The National Instruments PXIe-4340 is a four-channel, 24-bit PXI Express displacement input module for AC linear variable differential transformer (LVDT), AC rotary variable differential transformer (RVDT), resolver, and synchro measurements. It supports 4-, 5-, and 6-wire LVDT and RVDT connections.
Each channel uses a dedicated 24-bit delta-sigma ADC and can be sampled simultaneously at up to 25.6 kS/s per channel. The module independently configures excitation voltage and frequency for each channel, provides remote sense to compensate for excitation-lead resistance, and includes self-calibration, overcurrent detection, and open-coil detection. NI-DAQmx is the supported driver and configuration interface.
Key Technical Specifications
| Attribute | Specification |
|---|---|
| Manufacturer | National Instruments (NI) |
| Model | PXIe-4340 |
| Part number | 785068-01 |
| Product type | Filtered AC LVDT/RVDT displacement input module |
| Form factor | 3U PXI Express module |
| Analog-input channels | 4 |
| ADC resolution | 24 bits per channel |
| ADC type | Delta-sigma |
| Sampling mode | Simultaneous |
| Sample-rate range | 1 S/s to 25.6 kS/s per channel |
| Sample-rate resolution | 181.9 µS/s or less |
| Absolute input range | 7 Vrms |
| Maximum working voltage, signal plus common mode | 4 Vrms |
| Differential input impedance | 200 kΩ |
| Linearity | 0.01% |
| Crosstalk | −100 dB |
| Input protection | ±30 V |
| FIFO buffer | 1,023 samples |
| Data transfer modes | DMA and programmed I/O |
| Excitation type | Constant differential voltage, balanced |
| Excitation voltage range | 1 Vrms to 7 Vrms, in 0.5 Vrms steps |
| Excitation frequency range | 400 Hz to 10 kHz, in 10 Hz steps |
| Excitation output impedance | 3 Ω |
| Excitation current drive | 30 mA |
| Excitation gain accuracy | 5% maximum |
| Excitation DC offset | ±10 mV maximum |
| Remote sense | Per-channel excitation remote-sense inputs |
| Open-coil detection | AI/RS threshold ±12 V; excitation threshold greater than 5 kΩ; detection time 200 ms |
| Digital trigger/sync terminal | PFI 0, 3.3 V digital signal |
| Front connector | 68-pin VHDCI |
| Compatible terminal block | TB-4340 |
| Operating temperature | 0 °C to 55 °C |
| Storage temperature | −40 °C to 85 °C |
| Operating humidity | 10% to 90% RH, noncondensing |
| Maximum operating altitude | 2,000 m |
| Software | NI-DAQmx; driver support first available in NI-DAQmx 15.5 |
Engineering Selection Highlights
- The PXIe-4340 provides four dedicated 24-bit delta-sigma ADCs, so all four channels can be acquired simultaneously at the selected rate.
- Its 1 Vrms to 7 Vrms, 400 Hz to 10 kHz excitation range is independently programmable per channel, allowing different LVDT/RVDT sensor requirements to coexist on one module.
- The module supports 4-, 5-, and 6-wire LVDT and RVDT measurements, with remote sense used to reduce gain error caused by excitation-lead resistance.
- Resolver measurement requires two synchronized channels, while synchro measurement requires three synchronized channels; plan channel allocation accordingly.
- The 7 Vrms absolute input range and 4 Vrms signal-plus-common-mode working voltage define the electrical boundary for direct sensor connection.
- The module includes open-coil and overcurrent diagnostics, which support wiring-fault detection and protection of the excitation output.
- The TB-4340 front-mount terminal block is the documented field-wiring accessory for the PXIe-4340.

PXIe-4340

PXIe-4340
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Chassis slot | PXI Express or PXI Express hybrid slot | The module is a PXI Express peripheral module. |
| Analog inputs | AI<0..3>+, AI<0..3>−, differential | Each channel includes a dedicated 24-bit ADC and low-pass input filtering. |
| Sensor excitation | EX<0..3>+, EX<0..3>− | Excitation voltage and frequency are software-selectable per channel. |
| Remote sense | RS<0..3>+, RS<0..3>− | Connect remote-sense leads as close to the sensor as possible to compensate for lead resistance. |
| LVDT/RVDT wiring | 4-, 5-, and 6-wire configurations | For 5-wire sensors, NI recommends leaving the center tap disconnected; for 6-wire sensors, connect the two center-tap leads together or to the floating CT terminal. |
| Resolver connection | Two synchronized channels | Use one channel’s excitation, not both; configure remote sense on both channels. |
| Synchro connection | Three synchronized channels | Use one channel’s excitation; configure remote sense on all three channels. |
| Digital timing | PFI 0 | A 3.3 V digital terminal supports trigger and synchronization signals. |
| PXI timing resources | PXIe_CLK100, PXIe_SYNC100, PXI_CLK10, PXI triggers, PXI star trigger, PXIe_DSTAR | These resources support synchronization with other PXI Express modules. |
| Terminal block | TB-4340, part number 784087-01 | Provides front-mount field-wiring terminals and excitation-verification points. |
| Software | NI-DAQmx | Driver support was first available in NI-DAQmx 15.5. |
| Cabling | Twisted, shielded pair cables and shielded accessories | Required for specified EMC performance; I/O cables must not exceed 30 m (100 ft.). |
Dimensions, Mounting & Connection Notes
The PXIe-4340 is a 3U PXI Express module with a 68-pin VHDCI front connector. It is designed for use with the TB-4340 front-mounting terminal block, part number 784087-01.
The front connector provides, for each of the four channels:
- AI+ and AI− — differential analog-input pair.
- EX+ and EX− — differential sensor-excitation output pair.
- RS+ and RS− — differential remote-sense input pair.
- AIGND — analog-input ground.
The module also provides PFI 0 for trigger and synchronization signals, DGND for digital ground, and reserved accessory-communication pins. The TB-4340 adds excitation-verification terminals pulled to the excitation lines through 4.7 kΩ resistors, allowing gross external checks of excitation voltage.
For EMC performance, NI specifies twisted, shielded pair cables for channel connections and shielded cables and accessories for the complete I/O path. The maximum I/O cable length is 30 m (100 ft.).
Detailed Product Overview
The NI PXIe-4340 is a four-channel SC Express displacement input module designed for AC-excited position sensors. It combines sensor excitation, remote-sense correction, analog filtering, 24-bit delta-sigma digitization, digital demodulation, and PXI Express timing in one module.
Each channel has an independent excitation source. The excitation voltage can be set from 1 Vrms to 7 Vrms in 0.5 Vrms steps, and the excitation frequency can be set from 400 Hz to 10 kHz in 10 Hz steps. The excitation output is a balanced, constant differential voltage with a 3 Ω output impedance and 30 mA current-drive capability. Remote-sense inputs measure the excitation voltage near the sensor and compensate for voltage drop in long or small-gauge excitation leads.
The analog-input path applies low-pass filtering to both the input and remote-sense signals before digitization. Each channel is digitized by a dedicated 24-bit delta-sigma ADC, allowing all four channels to be sampled simultaneously. After conversion, the module digitally demodulates the signals and determines the ratiometric amplitude and phase relationship used for LVDT/RVDT displacement measurement.
The module supports two acquisition approaches. Buffered Mode applies digital filtering to reject excitation and out-of-band content, producing an accurate displacement representation with the group delay associated with those filters. Hardware-Timed Single Point Mode reduces filtering in the data path to lower latency, making it relevant for real-time control loops. NI notes that the maximum 25.6 kS/s sample rate, analog delay, filter delay, transfer time, and application time must all be considered when calculating achievable control bandwidth.
Diagnostics include self-calibration, open-coil detection, and overcurrent detection. Self-calibration adjusts ratiometric gain and offset and nulls the DC component of the excitation source; the module does not support external adjustment. Open-coil detection senses disconnection on AI and remote-sense lines and detects high impedance on excitation lines. Overcurrent detection disables excitation through an output relay for approximately one second when excessive current is detected.
The PXIe-4340 integrates with PXI Express timing resources including PXIe_CLK100, PXIe_SYNC100, PXI_CLK10, PXI trigger lines, the PXI star trigger, and PXIe_DSTAR lines. Channels on the same module configured with the same excitation frequency and amplitude are automatically synchronized. This synchronization is required for resolver and synchro measurements, which use multiple channels per sensor.
The module operates from 0 °C to 55 °C at 10% to 90% noncondensing relative humidity and up to 2,000 m altitude. It is designed to meet IEC 61010-1, EN 61010-1, UL 61010-1, and CSA 61010-1 safety-standard requirements. For EMC compliance, NI specifies shielded cables and accessories, with a maximum I/O cable length of 30 m.
Applications & System Role
The PXIe-4340 serves as the displacement-sensor measurement stage in a PXI Express data-acquisition or control system. It excites AC LVDT and RVDT sensors, digitizes their differential output signals, demodulates the resulting AC signals, and returns ratiometric displacement measurements to software.
Its resolver and synchro support extends the module beyond simple LVDT/RVDT measurement. A resolver requires two synchronized channels to measure sine and cosine signals, while a synchro requires three synchronized channels for its three stator signals. Remote sense is required on the channels used for these measurements to maintain accuracy.
The module is appropriate for high-resolution position and angle measurements where AC-excited inductive sensors are already installed. Its simultaneous sampling, independent excitation settings, diagnostics, and PXI Express synchronization resources make it suitable for multi-channel displacement measurement and closed-loop control applications.
FAQ
What is the NI PXIe-4340?
The NI PXIe-4340 is a four-channel, 24-bit PXI Express displacement input module for AC LVDT, RVDT, resolver, and synchro measurements.
What sensors does the PXIe-4340 support?
It supports 4-, 5-, and 6-wire AC LVDTs and RVDTs, as well as resolvers and synchros.
What is the maximum sample rate?
The maximum sample rate is 25.6 kS/s per channel. The supported range is 1 S/s to 25.6 kS/s.
What excitation does the module provide?
Each channel provides independently selectable balanced differential excitation from 1 Vrms to 7 Vrms and 400 Hz to 10 kHz.
How many channels are needed for resolver and synchro measurements?
A resolver requires two synchronized channels. A synchro requires three synchronized channels.
Why does the PXIe-4340 include remote sense?
Remote sense measures the excitation voltage near the sensor and compensates for gain error caused by resistance in the excitation leads.
Which terminal block is used with the PXIe-4340?
The TB-4340 front-mounting terminal block, part number 784087-01, is the documented accessory for field wiring.
What software controls the PXIe-4340?
NI-DAQmx controls and configures the module; driver support was first available in NI-DAQmx 15.5.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626