Sale!

NI SCXI-1162 32-Channel Optically Isolated Digital Input Module

Parameter Verified Specification
Manufacturer National Instruments (NI)
Model SCXI-1162
Product type Optically isolated digital input module
System family SCXI
Input channels 32 digital input lines
Input organization Eight isolated banks of four channels
Logic compatibility TTL and CMOS
Categories: , , , , SKU: SCXI-1162 Brand:

Description

Core Product Summary

The NI SCXI-1162 is a 32-channel optically isolated digital input module for the National Instruments SCXI signal-conditioning platform. It acquires discrete logic signals and provides isolation between field inputs and the measurement system.

The module accepts TTL and CMOS-compatible signals and can operate in serial multiplexed mode through the SCXIbus or in high-speed parallel mode with a compatible digital DAQ device. Its 32 inputs are arranged as eight isolated banks of four channels, and it uses an external terminal block for field connections.

 

Key Technical Specifications

Parameter Verified Specification
Manufacturer National Instruments (NI)
Model SCXI-1162
Product type Optically isolated digital input module
System family SCXI
Input channels 32 digital input lines
Input organization Eight isolated banks of four channels
Logic compatibility TTL and CMOS
Isolation 450 Vrms working isolation
Breakdown rating 1,900 Vrms
Operating modes Serial multiplexed mode or parallel mode
Parallel data width 24 or 32 lines, jumper-selectable
Configuration controls Four user-configurable jumpers
Factory configuration Serial mode for use with a DIO device
Field connection SCXI-1326 or TBX-1326 terminal block

The channel count, isolation, logic compatibility, operating modes, and jumper configuration are described in NI SCXI documentation. The terminal-block connection is documented in the TBX-1326 installation guide.

 

Engineering Selection Highlights

  • 32 isolated input lines → the module is suited to monitoring a substantial number of discrete status signals within one SCXI module.
  • Eight banks of four channels → bank grouping is relevant to wiring layout and isolation planning when field signals are connected through the terminal block.
  • TTL and CMOS compatibility → the module is intended for logic-level inputs, not for direct connection to high-voltage AC or DC field signals.
  • 450 Vrms working isolation → isolation is a system-design feature between the field side and the measurement system, not an instruction to apply 450 Vrms to an input.
  • Serial or parallel operation → serial mode supports multiplexed operation through the SCXIbus, while parallel mode supports higher-speed transfer to a compatible digital DAQ device.
  • Jumper configuration → the operating mode and connected DAQ-device type must be set correctly before integration; the module ships configured for serial operation with a DIO device.
  • SCXI-1326 or TBX-1326 terminal block → field wiring is connected through an external terminal block rather than directly to the module front connector.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Signal-conditioning platform National Instruments SCXI The module is installed in an SCXI system.
Chassis SCXI chassis The module operates as an installed SCXI digital input module.
DAQ hardware Compatible NI DAQ device Required to acquire the module’s digital input data.
Operating mode Serial multiplexed mode or parallel mode Serial mode is the shipped configuration; parallel mode requires jumper configuration.
Parallel mode width 24 or 32 parallel lines The selected width depends on the connected digital DAQ device.
Field wiring SCXI-1326 or TBX-1326 terminal block Provides the external screw-terminal interface for the module.
Input signals TTL and CMOS-compatible logic signals Verify signal level and grounding before field connection.

The TBX-1326 documentation identifies the SCXI-1162’s terminal functions as Vcc, digital input channels, and ground, while the module documentation defines its serial and parallel operating modes.

SCXI-1162

SCXI-1162

SCXI-1162

SCXI-1162

Detailed Product Overview

 

Isolated digital input architecture

The SCXI-1162 provides 32 optically isolated digital input channels. NI documentation describes the module as a digital-input module with 450 Vrms isolation and 1,900 Vrms breakdown capability. These ratings describe the isolation barrier of the module, not the permitted voltage on an individual logic input.

The inputs are organized into eight banks of four channels. The TBX-1326 terminal block provides corresponding groups containing a supply/reference terminal, ground, and four channel terminals. This grouping is relevant to wiring design because the terminal block’s banks are isolated from one another.

 

Two operating modes affect integration

The module can operate in serial multiplexed mode through the SCXIbus or in parallel mode with a compatible digital DAQ device. The SCXI-1162 is shipped configured for serial operation with a DIO device.

In parallel mode, the module can transfer either 24 or 32 lines. The 24-line setting is required for a DIO-24 device or the digital connector of an MIO-16D, while the 32-line setting applies to compatible configurations. These selections are made with module jumpers.

 

Configuration must match the DAQ connection

The module has four user-configurable jumpers for operating mode and DAQ-device type. NI documentation directs users to leave non-applicable jumpers in their factory-default positions and to adjust only the jumpers needed for the selected connection method.

Because the SCXI-1162 is not a standalone acquisition device, the complete system includes the SCXI chassis, the module, its terminal block, and a compatible NI DAQ device. The DAQ device performs the acquisition function, while the SCXI-1162 provides isolated digital-input conditioning and routing.

 

Applications & System Role

The SCXI-1162 functions as the digital-input conditioning stage in an NI SCXI measurement system. It receives discrete logic signals from field devices or test circuits, provides optical isolation, and transfers the resulting input states to the connected DAQ hardware.

A technical-fit scenario is a test or monitoring system that needs to acquire many TTL or CMOS status signals while maintaining isolation between the field wiring and the DAQ system. The module’s serial mode supports SCXIbus-based multiplexed acquisition, while parallel mode is relevant when a compatible digital DAQ device can use direct parallel data transfer.

 

FAQ

 

What is the NI SCXI-1162?

It is a 32-channel optically isolated digital input module for National Instruments SCXI signal-conditioning systems.

 

How many input channels does it provide?

It provides 32 digital input channels, organized as eight isolated banks of four channels.

 

What input signal types does it accept?

It accepts TTL and CMOS-compatible logic signals.

 

What isolation does the SCXI-1162 provide?

NI documentation specifies 450 Vrms working isolation and 1,900 Vrms breakdown capability.

 

Can it operate in parallel mode?

Yes. It supports parallel operation with a compatible digital DAQ device and can transfer 24 or 32 lines, depending on the jumper setting.

 

Which terminal block connects field wiring?

The SCXI-1326 or TBX-1326 terminal block connects field signals to the module.

 

Is the SCXI-1162 a standalone data-acquisition device?

No. It is an SCXI digital input module and requires an SCXI chassis and a compatible NI DAQ device to acquire data.