Description
Core Product Summary
The NI SCXI-1162HV is a 32-channel optically isolated digital input module for the SCXI signal conditioning platform. It senses the presence of a wide range of AC or DC signals, from digital logic levels up to 240 VAC/VDC, and organizes the inputs into eight independently isolated banks of four channels each.
Optical isolation eliminates ground-loop problems and protects the host computer from high common-mode voltages. The module supports both multiplexed (serial) operation over the SCXIbus and parallel mode when connected directly to a compatible digital I/O device. It is intended for monitoring power circuits, switches, relays, and similar field signals in laboratory, production, and industrial process applications.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Product type | 32-channel optically isolated digital input module |
| Channels | 32, arranged in 8 optically isolated banks of 4 inputs each |
| Input signal range | Logic-level to 240 VAC / 240 VDC |
| Input high voltage (examples) | ≥2 VDC; ≥10 VAC (50/60 Hz); ≥2 VAC (1 kHz) |
| Input low voltage | ≤1 V (DC or peak AC) |
| Input current limiting | 1 mA |
| Isolation | 300 Vrms between banks and bank-to-earth (working) |
| Propagation delay (parallel mode) | 1.5 ms |
| Serial data rate (multiplexed mode) | 1,000 words/s (1 word = 32 bits) |
| Operating temperature | 0 to 50 °C |
| Dimensions | 1.2 × 6.8 × 8.0 in |
| Connectors | 50-pin male ribbon-cable rear; 48-pin DIN C male front |
Detailed Product Overview
The SCXI-1162HV provides high-voltage digital input capability within an SCXI system. Each of the 32 channels detects the presence or absence of an AC or DC voltage and reports a corresponding logic state to the controlling data acquisition device. The channels are grouped into eight banks of four; optical isolation between banks and between each bank and earth ground allows the module to monitor signals that share no common reference or that float at high common-mode potentials relative to the measurement system.
The module accepts signals ranging from TTL/CMOS logic levels up to 240 VAC or 240 VDC. Current limiting of 1 mA protects the input circuitry. In parallel mode the propagation delay is typically 1.5 ms. In multiplexed mode the module transfers 32-bit data words over the SCXIbus at rates up to 1,000 words per second, allowing a single DAQ device to read multiple SCXI-1162HV modules without dedicating a large number of digital lines.
Field wiring is normally brought to the module through the SCXI-1326 or TBX-1326 terminal block, which provides screw terminals rated for the higher voltages. The module itself mounts in any SCXI chassis slot and presents a 48-pin DIN C front connector and a 50-pin rear connector for SCXIbus and DAQ-device interconnection.
Configuration is performed with on-board jumpers that select serial versus parallel operation and match the rear-connector pinout to the type of DAQ device in use (MIO/AI or dedicated DIO boards such as the DIO-24, DIO-32, or DIO-96 family). Once configured, the module operates as a straightforward digital input front end: the host software simply reads the 32-bit port state.
Typical applications include sensing the on/off status of power circuits, proximity switches, push-button stations, thermostats, and relay contacts where isolation from high voltages or noisy industrial grounds is required.

SCXI-1162HV

SCXI-1162HV
Dimensions, Mounting & Connection Notes
- Dimensions: 1.2 × 6.8 × 8.0 in
- Mounting: Standard SCXI front-panel thumbscrews secure the module to the chassis rails.
- Front connector: 48-pin DIN C male; mates with SCXI-1326 or TBX-1326 terminal blocks.
- Rear connector: 50-pin male ribbon-cable for SCXIbus and DAQ-device cabling.
- Field wiring: Use wire and terminal blocks rated for the maximum applied voltage (up to 240 VAC/VDC).
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Chassis | Any SCXI chassis | Install with chassis powered off |
| DAQ devices (multiplexed) | MIO series, Lab series, SCXI-1200 | Uses serial protocol over SCXIbus |
| DAQ devices (parallel) | DIO-24, DIO-32F/HS, DIO-96 and similar | Direct cabling of all 32 lines |
| Terminal blocks | SCXI-1326, TBX-1326 | Provide high-voltage screw terminals; note voltage derating when using certain cables |
| Operating modes | Multiplexed (serial) or parallel | Selected by jumpers; parallel mode requires a dedicated digital I/O device |
| Software | NI-DAQ / Traditional NI-DAQ and compatible environments | Module appears as a 32-bit digital input port |
FAQ
What is the NI SCXI-1162HV?
It is a 32-channel optically isolated digital input module for the SCXI platform that senses AC or DC voltages from logic levels up to 240 VAC/VDC.
How are the channels organized?
The 32 inputs are grouped into eight optically isolated banks of four channels each, providing isolation between banks and from bank to earth ground.
What voltages can the module sense?
It detects the presence of signals ranging from digital logic levels up to 240 VAC or 240 VDC.
What isolation rating does the SCXI-1162HV provide?
Each bank is optically isolated with a working isolation rating of 300 Vrms between banks and between each bank and earth ground.
Can the module operate in parallel mode?
Yes. When jumper-configured for parallel operation and cabled directly to a compatible digital I/O device (such as a DIO-24, DIO-32, or DIO-96), all 32 channels are available simultaneously.
Which terminal block is used with the SCXI-1162HV?
The SCXI-1326 or TBX-1326 high-voltage terminal blocks provide the screw-terminal interface for field wiring.