Description
Core Product Summary (Brand / Model / Key Attributes)
The National Instruments SCXI-1163R is a 32-channel solid-state relay switch module designed for deployment within modular SCXI data acquisition and control architectures. It provides thirty-two Form A (normally open), optically isolated solid-state relays organized into eight independent banks of four channels, featuring one common pole per bank. This topology enables dependable switching of control signals, indicators, and low-current load lines while protecting upstream hardware from high common-mode transients.
Engineered for dense switching applications, the SCXI-1163R supports a maximum switching voltage of up to 240 VAC/VDC (Category II) and a maximum switching current of 200 mA per channel. The solid-state design delivers fast actuation times—featuring a 1.5 ms turn-on time and a 0.25 ms turn-off time—alongside high reliability and freedom from mechanical contact wear. The module is programmed serially over the SCXIbus or via dedicated control connections, integrating seamlessly with NI-SWITCH and NI-DAQmx driver environments.
Key Technical Specifications
| Specification | Value / Detail |
| Product Type | 32-Channel Optically Isolated Solid-State Relay Switch Module |
| Number of Channels | 32 channels |
| Relay Configuration | 8 banks of 4 relays with one common pole per bank (Form A, normally open) |
| Relay Type | Solid-state relays |
| Maximum Switching Voltage | 240 VAC / 240 VDC, CAT II (channel-to-common) |
| Maximum Switching Current | 200 mA per channel |
| Maximum Working Voltage | 450 V (bank-to-bank and bank-to-ground) |
| Relay Turn-On Time | 1.5 ms |
| Relay Turn-Off Time | 0.25 ms |
| DC Path Resistance | 8 Ω |
| Front I/O Connector | 48-pin DIN C male connector |
| Software Support | NI-SWITCH, NI-DAQmx driver software |
Detailed Product Overview
The National Instruments SCXI-1163R serves as a high-density switching and digital control interface designed to bridge automated test systems with external automation hardware, actuators, and indicators. By utilizing solid-state switching technology instead of traditional electromechanical armatures, the module eliminates contact bounce, reduces maintenance wear, and offers extended operational longevity in high-cycle testing environments.
The architecture organizes the 32 channels into eight distinct banks, with each bank providing four optically isolated relays sharing a single common pole. This modular grouping helps segregate different signal domains and maintains robust optical isolation across separate control loops. The integration of high working voltage boundaries (up to 450 V bank-to-bank and bank-to-ground) ensures safety and signal integrity when managing mixed-potential industrial environments.
Communication and control are handled natively through the SCXI chassis backplane (SCXIbus) or via direct serial control structures, allowing the module to be easily added to existing measurement racks. Software integration via NI-SWITCH and NI-DAQmx allows test engineers to incorporate switching sequences directly into automated measurement scripts using development environments like LabVIEW or LabWindows/CVI.

SCXI-1163R

SCXI-1163R
Engineering Selection Highlights
- Solid-State Reliability: Eliminates mechanical wear and contact bounce by utilizing solid-state relays, ensuring consistent long-term performance in high-frequency actuation applications.
- Optically Isolated Bank Topology: Organizes 32 channels into 8 isolated banks of 4, preventing cross-channel interference and protecting control architecture from external fault conditions.
- Rapid Response Times: Delivers quick switching speeds with a 1.5 ms turn-on time and a 0.25 ms turn-off time.
- Flexible Voltage and Current Limits: Supports switching up to 240 VAC/VDC at 200 mA per channel, making it well-suited for status indicators, solenoids, and low-current control loads.
- Streamlined Software Integration: Fully compatible with NI-SWITCH and NI-DAQmx driver frameworks for rapid configuration within automated test routines.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Chassis Architecture | National Instruments SCXI Chassis | Must be installed in a compatible SCXI enclosure equipped with an active backplane. |
| Controller / DAQ Board | NI DAQ controllers supporting SCXI architectures | Provides communication control over the SCXIbus or via direct serial/parallel cabling. |
| Driver Software | NI-SWITCH or NI-DAQmx driver software | Required for programmatic control, channel routing, and integration into test management software. |
| Front Connection Interface | 48-pin reversed DIN C female connector mating to the 48-pin DIN C male front panel | Used for secure connection of field wiring harnesses to the relay channels. |
Dimensions, Mounting & Connection Notes
- Physical Dimensions: 3.0 cm × 17.3 cm × 19.6 cm (1.2 in. × 6.7 in. × 7.6 in.)
- Weight: 625 g (1 lb 6 oz)
- Form Factor: Standard front-loading SCXI module slot-compatible design.
- Front I/O Connection: Utilizes a 48-pin DIN C male connector; requires a corresponding reversed DIN C female mating connector with proper shielding to maintain EMC performance.
- Operating Environment: Designed for indoor use within a 0 °C to 50 °C temperature range and 5% to 85% noncondensing relative humidity (Pollution Degree 2).
FAQ
What is the NI SCXI-1163R?
The NI SCXI-1163R is a 32-channel solid-state relay switch module built for SCXI data acquisition and instrumentation systems.
How are the relays on the SCXI-1163R configured?
The 32 Form A (normally open) solid-state relays are arranged into eight distinct banks of four channels, with each bank sharing one common pole.
What are the maximum switching voltage and current ratings?
The module supports a maximum switching voltage of 240 VAC/VDC (CAT II) and a maximum switching current of 200 mA per channel.
What is the advantage of solid-state relays over standard electromechanical relays in this module?
Solid-state relays provide faster actuation times, freedom from mechanical wear, zero contact bounce, and enhanced reliability in high-cycle automation tasks.
What software drivers are required to operate the module?
The module is operated using either the NI-SWITCH instrument driver or the NI-DAQmx driver software package.
Verification & Troubleshooting Notes
- Check Driver Configuration: If channel communication fails, verify that the appropriate version of NI-SWITCH or NI-DAQmx is installed and that the module is properly addressed within the chassis configuration.
- Load Verification: Ensure that connected loads do not exceed the 200 mA current limit or 240 V switching threshold to prevent thermal damage to the solid-state switching elements.
- Shielding Compliance: Confirm that field cabling utilizes proper shielding attached to ground to satisfy electromagnetic compatibility (EMC) requirements and minimize noise coupling.