Description
Core Product Summary
The NI SCXI-1193 is a high-density 32-channel RF relay multiplexer switch module for the National Instruments SCXI platform. It is designed for signal routing from DC to beyond 500 MHz in 50 Ω RF test and measurement systems.
The module can be software-configured as unterminated multiplexers, externally terminated multiplexers, or a dimensionally flexible sparse matrix. Its 50 Ω characteristic impedance, MCX RF connectors, and multiple routing topologies make it suitable for integration with high-frequency instruments such as PXI arbitrary waveform generators and oscilloscopes.
Key Technical Specifications
| Parameter | Verified Specification |
|---|---|
| Manufacturer | National Instruments (NI) |
| Model | SCXI-1193 |
| Part number | 776572-93 |
| Product type | RF multiplexer switch module |
| System family | SCXI |
| Channel count | 32 RF channels |
| Characteristic impedance | 50 Ω nominal |
| RF frequency capability | DC to beyond 500 MHz |
| Insertion loss, 8×1 topology | Less than 1.4 dB from DC to 200 MHz; less than 2.4 dB from 200 MHz to 500 MHz |
| Typical 3 dB bandwidth, 8×1 topology | Greater than 900 MHz |
| Typical 3 dB bandwidth, 16×1 topology | Greater than 750 MHz |
| Typical 3 dB bandwidth, 32×1 topology | Greater than 600 MHz |
| Maximum switching voltage | 60 VDC, Measurement Category I |
| Transient overvoltage withstand | Up to 800 Vpk |
| Maximum switching current | 0.5 A per channel |
| Maximum carry current | 1 A per channel |
| Maximum switching power | 10 W per channel |
| Maximum RF carry power | 10 W up to 500 MHz per channel |
| Maximum scan rate | 100 channels/s |
| Relay type | Electromechanical, latching |
| I/O connectors | 36 MCX jacks |
| Trigger connectors | 2 SMB jacks |
| Software | NI-SWITCH driver |
The specifications above are taken from NI’s SCXI-1193 specifications and product documentation.
Engineering Selection Highlights
- 32 RF channels with 50 Ω impedance → the module is intended for RF signal routing rather than general-purpose low-frequency relay switching.
- Multiple routing topologies → the same module can be configured as 32×1, dual 16×1, or quad 8×1 multiplexers, allowing the routing architecture to match the test system.
- Terminated multiplexer options → external termination can be applied to selected configurations, which is relevant when matching RF signal paths.
- 10 W RF carry power per channel → RF power handling is limited per channel and must be evaluated together with frequency and insertion-loss heating.
- 60 VDC, CAT I switching limit → the module is intended for signal-level routing, not for switching mains or high-energy power circuits.
- 100 channels/s maximum scan rate → switching speed is limited and should be checked against the required test sequence rate.
- NI-SWITCH software support → route configuration is performed through the NI-SWITCH driver environment.

SCXI-1193

SCXI-1193
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Signal-conditioning platform | NI SCXI | The module is installed in an SCXI system. |
| RF instruments | PXI arbitrary waveform generator, PXI oscilloscope, and comparable high-frequency instruments | The module routes RF signals between instruments and devices under test. |
| Routing topology | 32×1, dual 16×1, quad 8×1, terminated multiplexers, or sparse matrix | Select and configure the topology through software. |
| RF connections | 36 MCX jacks | Use appropriate MCX-based RF cabling and adapters. |
| Trigger connections | 2 SMB jacks | Supports trigger input and output routing. |
| Control software | NI-SWITCH driver | Required for switch configuration and route control. |
| Power supply | +18.5 to +25 VDC at 170 mA | Provided through the SCXI chassis power architecture. |
NI identifies the SCXI-1193 as supported by the NI-SWITCH driver and describes its integration with high-frequency PXI instruments.
Detailed Product Overview
RF routing rather than general-purpose switching
The SCXI-1193 is a 50 Ω RF relay module with 32 channels. NI describes it as a high-density RF multiplexer intended to carry signals from DC to beyond 500 MHz. Its MCX connectors, 50 Ω impedance, and RF power and insertion-loss specifications distinguish it from general-purpose digital or power-relay modules.
The module’s switching ratings are 60 VDC, 0.5 A switching current, and 1 A carry current per channel. NI identifies the module as Measurement Category I and states that it is intended for signal voltages no greater than 60 VDC.
Topology is software-defined
The SCXI-1193 can be configured as a single 32×1 multiplexer, dual 16×1 multiplexers, or quad 8×1 multiplexers. It also supports externally terminated multiplexer configurations and dimensionally flexible sparse matrices.
NI documentation also describes less conventional configurations. The module’s 32 channels can be divided into eight 3×1 multiplexers, with the four common terminals able to form a ninth 3×1 multiplexer. In the 32×1 topology, all channels route to COM0; the unused COM terminals can become additional channels in independent topologies, producing 17×1 or 35×1 unterminated multiplexers.
RF performance depends on topology
NI specifies different bandwidth and insertion-loss characteristics by topology. For an 8×1 configuration, insertion loss is less than 1.4 dB from DC to 200 MHz and less than 2.4 dB from 200 MHz to 500 MHz, with typical 3 dB bandwidth greater than 900 MHz. For a 32×1 configuration, typical 3 dB bandwidth is greater than 600 MHz.
This means that the number of channels combined into one signal path affects RF performance. A system requiring the highest available bandwidth should favor a smaller multiplexer topology where the application permits it.
Switching and trigger behavior
The module uses electromechanical latching relays and has a maximum scan rate of 100 channels/s. Its trigger inputs and outputs can use SCXI trigger lines, the front panel, or the rear connector. Trigger input pulses have a minimum width of 150 ns, while output pulse width is programmable from 1 μs to 62 μs.
The module provides 36 MCX jacks for RF input/output connections and 2 SMB jacks for trigger connections. It is controlled through the NI-SWITCH driver, which supports route configuration and switch operation.
Applications & System Role
The SCXI-1193 is the RF signal-routing stage in an NI SCXI-based test system. It connects RF sources, instruments, and devices under test through software-controlled relay paths, allowing one instrument connection to be routed among multiple channels.
A technical-fit scenario is an RF test system in which a signal generator, oscilloscope, or other high-frequency instrument must be selectively connected to different test points. The module can consolidate those connections into a 32×1 multiplexer, split them into independent 16×1 or 8×1 multiplexers, or implement a sparse-matrix routing arrangement.
FAQ
What is the NI SCXI-1193?
It is a 32-channel, 50 Ω RF multiplexer switch module for the NI SCXI platform, capable of routing signals from DC to beyond 500 MHz.
What routing topologies does it support?
It supports a 32×1 multiplexer, dual 16×1 multiplexers, quad 8×1 multiplexers, externally terminated multiplexers, and sparse-matrix configurations.
What is its characteristic impedance?
The SCXI-1193 has a nominal 50 Ω characteristic impedance.
What RF bandwidth does it provide?
Typical 3 dB bandwidth is greater than 900 MHz in an 8×1 topology, greater than 750 MHz in a 16×1 topology, and greater than 600 MHz in a 32×1 topology.
What voltage and current can it switch?
It is rated for 60 VDC switching voltage, 0.5 A switching current, and 1 A carry current per channel.
What connectors does it use?
It provides 36 MCX jacks for RF input/output connections and 2 SMB jacks for trigger connections.
Which software controls the module?
The module is controlled with the NI-SWITCH driver.
What is its maximum scan rate?
The SCXI-1193 has a maximum scan rate of 100 channels/s.