Sale!

NI SCXI-1303 32-Channel Isothermal Thermocouple Terminal Block

Parameter Verified Specification
Manufacturer National Instruments (NI)
Model SCXI-1303
Product type 32-channel isothermal terminal block
Compatible SCXI modules SCXI-1100, SCXI-1102, SCXI-1102B, SCXI-1102C
Screw terminals 78 total
Input channels 32 differential input channel pairs
Chassis-ground terminals One pair
Module interface terminals OUTPUT, AOREF, and SCXIbus GUARD
Categories: , , , , SKU: SCXI-1303 Brand:

Description

Core Product Summary

The NI SCXI-1303 is a 32-channel isothermal terminal block for National Instruments SCXI-1100 and SCXI-1102/B/C analog input modules. It provides screw-terminal field connections for thermocouples and other differential voltage signals.

The terminal block includes an isothermal copper plane and a high-accuracy thermistor cold-junction sensor. It also provides circuitry for open-thermocouple detection and automatic ground referencing for floating thermocouples.

 

Key Technical Specifications

Parameter Verified Specification
Manufacturer National Instruments (NI)
Model SCXI-1303
Product type 32-channel isothermal terminal block
Compatible SCXI modules SCXI-1100, SCXI-1102, SCXI-1102B, SCXI-1102C
Screw terminals 78 total
Input channels 32 differential input channel pairs
Chassis-ground terminals One pair
Module interface terminals OUTPUT, AOREF, and SCXIbus GUARD
Reserved terminals OUT0+, OUT0–, OUT1+, OUT1–, OUT2+, OUT2–, OUT3+, OUT3–, AIREF
Cold-junction sensor type Thermistor
Sensor output range 1.91 to 0.58 V from 0 to 55°C
Sensor accuracy ±0.5°C from 15 to 35°C; ±0.9°C from 0 to 15°C and 35 to 55°C
Sensor repeatability ±0.2°C from 15 to 35°C
Construction Shielded enclosure with isothermal copper plane
Thermocouple support Open-thermocouple detection and automatic ground referencing

The terminal count, module compatibility, cold-junction sensor performance, and isothermal construction are specified in the SCXI-1303 installation guide.

 

Engineering Selection Highlights

  • 32 differential channel pairs → the terminal block matches the 32 differential input channels of compatible SCXI analog input modules.
  • Isothermal copper plane → reduces temperature gradients across the screw terminals, which is material for thermocouple cold-junction measurement accuracy.
  • Thermistor cold-junction sensor → provides the temperature reference required for thermocouple measurement at the terminal block.
  • Open-thermocouple detection circuitry → pullup and bias resistors can saturate the connected module amplifier output when a thermocouple opens.
  • Automatic ground referencing → supports floating, non-grounded thermocouples by referencing them to chassis ground.
  • SCXI-1100 and SCXI-1102/B/C compatibility → the block is specifically intended for those module families, not as a universal terminal block for every SCXI module.
  • Shielded construction → supports signal-integrity planning for low-level thermocouple and voltage measurements.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
SCXI modules SCXI-1100, SCXI-1102, SCXI-1102B, SCXI-1102C The terminal block connects directly to these module families.
Thermocouple measurement Cold-junction compensation via onboard thermistor The terminal block supplies the cold-junction temperature reference.
Open-thermocouple detection Pullup resistor between CH+ and +5 V; bias resistor between CH– and chassis ground Supports detection of an open thermocouple through amplifier-output saturation.
Floating thermocouples Automatic ground referencing circuitry Provides a ground reference for floating signal sources.
Field wiring Screw terminals Provides direct screw-terminal connections for signal wiring.
Module interface OUTPUT, AOREF, and SCXIbus GUARD terminals Connects the terminal block to the associated SCXI module interface.

The SCXI-1303 is identified by NI as a terminal block for the SCXI-1100 and SCXI-1102/B/C modules, with thermistor-based cold-junction compensation.

SCXI-1303

SCXI-1303

Detailed Product Overview

 

Terminal block for thermocouple measurements

The SCXI-1303 is a shielded terminal block with 78 screw terminals. Thirty-two pairs of terminals connect to the 32 differential inputs of compatible SCXI modules, while one pair connects to the module’s chassis-ground pins.

NI identifies the SCXI-1303 as a terminal block designed especially for high-accuracy thermocouple measurements. Its isothermal construction minimizes thermal-gradient errors between the screw terminals and the cold-junction sensor.

 

Cold-junction compensation and accuracy

The terminal block includes a thermistor-based cold-junction temperature sensor. NI specifies an output range of 1.91 to 0.58 V over 0 to 55°C, with ±0.5°C accuracy from 15 to 35°C and ±0.9°C accuracy from 0 to 15°C and 35 to 55°C. Repeatability is ±0.2°C from 15 to 35°C.

For thermocouple measurements, the cold-junction sensor provides the reference temperature at the terminal block. The connected SCXI module and DAQ system use that information as part of the thermocouple measurement calculation.

 

Open-circuit detection and grounding

Each input channel includes a pullup resistor between CH+ and +5 V and a bias resistor between CH– and chassis ground. These resistors support open-thermocouple detection by saturating the connected module’s amplifier output when a thermocouple circuit opens.

The terminal block also provides automatic ground referencing for floating thermocouples. This is relevant when the thermocouple does not have its own ground reference and must be referenced to chassis ground for measurement.

 

Module compatibility

The SCXI-1303 is designed for use with SCXI-1100 and SCXI-1102/B/C modules. NI’s terminal-block selection guide identifies the SCXI-1303 as the thermistor-CJC terminal block for those module families.

The block also includes terminals for the SCXI module OUTPUT and AOREF pins and the SCXIbus GUARD. Additional OUT and AIREF terminals are reserved for future use.

 

Applications & System Role

The SCXI-1303 is the field-wiring and cold-junction interface between thermocouples or voltage signals and a compatible SCXI analog input module. It does not digitize signals; it conditions the physical connection environment and provides temperature-reference information to the SCXI measurement system.

A technical-fit scenario is a multichannel temperature-measurement system using thermocouples connected to an SCXI-1102 or SCXI-1100 module. The terminal block provides the isothermal connection point, cold-junction compensation, open-thermocouple detection, and ground referencing needed for that measurement architecture.

 

FAQ

 

What is the NI SCXI-1303?

It is a 32-channel isothermal terminal block for NI SCXI-1100 and SCXI-1102/B/C analog input modules.

 

Which SCXI modules can it connect to?

It is designed for the SCXI-1100, SCXI-1102, SCXI-1102B, and SCXI-1102C modules.

 

How many field connections does it provide?

It provides 78 screw terminals, including 32 differential input channel pairs and one pair of chassis-ground terminals.

 

Does it provide cold-junction compensation?

Yes. It includes a thermistor cold-junction sensor for thermocouple measurements.

 

What is the cold-junction sensor accuracy?

NI specifies ±0.5°C from 15 to 35°C and ±0.9°C from 0 to 15°C and 35 to 55°C. Repeatability is ±0.2°C from 15 to 35°C.

 

Does it detect an open thermocouple?

Yes. Pullup and bias resistors on each channel support open-thermocouple detection by saturating the module amplifier output.

 

Can it be used with floating thermocouples?

Yes. The terminal block includes automatic ground-referencing circuitry for floating, non-grounded thermocouples.

 

Is the SCXI-1303 a data-acquisition module?

No. It is a terminal block that provides field wiring, isothermal construction, cold-junction compensation, and related circuitry for compatible SCXI modules.