Description
Core Product Summary
The NI SCXI-1313A is a shielded front-mount terminal block designed specifically for the SCXI-1125 isolated analog input module. It provides eight channels of precision 100:1 resistive attenuation that can be enabled or bypassed on a per-channel basis through software, extending the measurable input range to 150 Vrms or ±150 VDC.
The terminal block includes 18 screw terminals for signal and ground connections and an onboard thermistor cold-junction sensor for thermocouple measurements. It mounts directly to the front of the SCXI-1125 and is rated for CAT II measurement category.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Product type | High-voltage attenuator terminal block |
| Compatible module | SCXI-1125 |
| Input channels | 8 |
| Attenuation | 100:1 or 1:1 (programmable per channel) |
| Maximum input range | 150 Vrms or ±150 VDC |
| Measurement category | CAT II |
| Cold-junction sensor | Thermistor |
| Sensor accuracy | ±0.5 °C (15 to 35 °C); ±0.9 °C (0 to 15 °C and 35 to 55 °C) |
| Sensor output | 1.91 to 0.65 V from 0 to 50 °C |
| Coupling | DC only |
| Common-mode isolation | 150 Vrms or ±150 VDC (channel-to-channel and channel-to-ground) |
| Screw terminals | 18 (8 signal pairs + 2 functional ground) |
| Maximum wire gauge | 16 AWG |
Detailed Product Overview
The SCXI-1313A expands the voltage measurement capability of the SCXI-1125 by placing a precision resistive divider in series with each of the eight input channels. When the 100:1 attenuation path is selected, the module can safely measure signals up to 150 Vrms or ±150 VDC while remaining within the input range of the SCXI-1125. For low-voltage applications the dividers can be bypassed individually through software configuration, restoring a 1:1 signal path.
The terminal block is fully shielded and attaches directly to the front connector of the SCXI-1125. Eighteen screw terminals provide convenient field wiring: eight differential pairs map to the module’s analog inputs, and two additional terminals connect to functional chassis ground. A strain-relief bar at the cable entrance helps secure the field wiring.
An onboard thermistor cold-junction sensor supports thermocouple measurements. The sensor produces a voltage output of 1.91 V to 0.65 V over the 0 to 50 °C range and is specified for ±0.5 °C accuracy between 15 and 35 °C. The sensor signal is available to the host module for cold-junction compensation.
Because attenuation is controlled programmatically, the user simply configures the desired input limits in software; the driver automatically selects the correct attenuation path and applies the corresponding scaling. This approach eliminates the need for manual switches or jumpers when changing between high-voltage and low-voltage ranges.
The SCXI-1313A is intended for indoor use in CAT II environments and accepts field wire up to 16 AWG.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Host module | only | Direct front-mount attachment |
| Attenuation control | Software-selectable (100:1 or 1:1) per channel | Configured via input limits in NI-DAQmx or MAX |
| Cold-junction compensation | Onboard thermistor sensor | Available for thermocouple measurements |
| Field wiring | Up to 16 AWG | Use wire rated for the applied voltage |
| Measurement category | CAT II | Suitable for local-level mains-connected circuits |
| Coupling | DC only | No AC-coupling option on this terminal block |
Dimensions, Mounting & Connection Notes
- Mounting: Direct front attachment to the SCXI-1125 module.
- Field connections: 18 screw terminals (8 differential pairs + 2 ground).
- Maximum wire size: 16 AWG.
- Strain relief: Integrated bar at the terminal-block entrance.
- Isolation: 150 Vrms / ±150 VDC channel-to-channel and channel-to-ground.

SCXI-1313A

SCXI-1313A
FAQ
What is the NI SCXI-1313A?
It is a shielded high-voltage attenuator terminal block for the SCXI-1125 that provides programmable 100:1 or 1:1 attenuation on each of eight channels and includes an onboard cold-junction sensor.
What voltage range does the SCXI-1313A support?
With the 100:1 attenuators enabled, the terminal block extends the measurable range to 150 Vrms or ±150 VDC.
How is attenuation selected?
Attenuation is selected programmatically on a per-channel basis by setting the appropriate input limits in software; no hardware switches are required.
Does the SCXI-1313A include cold-junction compensation?
Yes. It contains a thermistor cold-junction sensor with specified accuracy of ±0.5 °C from 15 to 35 °C.
Which module is the SCXI-1313A designed for?
It is designed exclusively for use with the SCXI-1125 isolated analog input module.
What is the measurement category rating?
The terminal block is rated CAT II.

WhatsApp: +86 16626708626