Description
Core Product Summary
The NI SCXI-1326 is a shielded high-voltage terminal block for National Instruments SCXI digital I/O modules. It provides 48 screw terminals for field signal connections to SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules.
The terminal block mounts directly to the front connector of a compatible SCXI module. Its terminals are arranged in eight isolated groups of six, with each group containing VCC, GND, and four channel terminals. The block provides 300 Vrms common-mode isolation between banks and between banks and earth ground.
Key Technical Specifications
| Parameter | Verified Specification |
|---|---|
| Manufacturer | National Instruments (NI) |
| Model | SCXI-1326 |
| Product type | High-voltage terminal block |
| System family | SCXI |
| Compatible modules | SCXI-1162, SCXI-1162HV, SCXI-1163, SCXI-1163R |
| Screw terminals | 48 |
| Terminal organization | Eight isolated groups of six terminals |
| Terminals per group | VCC, GND, and four channel terminals |
| Common-mode isolation, bank to bank | 300 Vrms |
| Common-mode isolation, bank to earth | 300 Vrms |
| Construction | Shielded board with front-connector mounting supports |
| Operating temperature | 0 to 50°C |
| Storage temperature | -20 to 70°C |
| VCC terminal use with SCXI-1162HV / SCXI-1163R | Not used |
| GND terminal use with SCXI-1162 | Not used |
The terminal count, compatible modules, isolation ratings, environmental limits, and module-specific terminal functions are documented in NI’s SCXI-1326 installation guide.
Engineering Selection Highlights
- 48 screw terminals → the block provides direct field-wiring connections for compatible SCXI digital I/O modules.
- Eight isolated six-terminal banks → wiring can be organized into isolated groups, with each bank containing VCC, GND, and four channels.
- 300 Vrms bank-to-bank and bank-to-earth isolation → isolation is defined between banks and earth ground, not as a per-channel input voltage rating.
- SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R compatibility → the block is intended for these specific digital I/O module families.
- Module-dependent VCC and GND use → the VCC terminals are not used with the SCXI-1162HV or SCXI-1163R, while the GND terminals are not used with the SCXI-1162.
- Front-connector mounting → the block attaches directly to the compatible SCXI module’s front connector, rather than connecting through a separate cable.
- Shielded enclosure → the construction supports signal-integrity planning for isolated digital I/O wiring.

SCXI-1326

SCXI-1326
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| SCXI modules | SCXI-1162, SCXI-1162HV, SCXI-1163, SCXI-1163R | Confirm the installed module belongs to one of these families. |
| Module connection | Direct connection to the module front connector | The terminal block mounts to the module’s mating front connector. |
| Field wiring | Screw terminals | Provides screw-terminal connections for field signals. |
| Bank isolation | 300 Vrms between banks and between banks and earth ground | Maintain the isolation boundary when planning wiring and grounding. |
| wiring | GND terminals are not used | Follow the module-specific terminal assignment. |
| / wiring | VCC terminals are not used | Follow the module-specific terminal assignment. |
| Installation environment | 0 to 50°C operating; -20 to 70°C storage | Check enclosure temperature and storage conditions. |
The compatible module list and module-specific use of VCC and GND terminals are stated in the SCXI-1326 installation guide.
Detailed Product Overview
High-voltage terminal block for isolated digital I/O
The SCXI-1326 is a shielded terminal block with 48 screw terminals. It is designed to connect field signals to the front connectors of NI SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules.
The terminal block is organized into eight groups of six terminals. Each group contains VCC, GND, and four channel terminals, and each group is isolated from the other groups. NI specifies 300 Vrms common-mode isolation both between banks and between banks and earth ground.
Terminal functions depend on the connected module
The VCC and GND terminals do not have the same function for every compatible module. NI specifies that VCC is not used with the SCXI-1162HV or SCXI-1163R, while GND is not used with the SCXI-1162. These differences must be followed when wiring the terminal block.
For the SCXI-1162, NI documentation describes the module as having 32 optically isolated digital inputs arranged as eight banks of four channels. The SCXI-1326 provides the matching banked terminal arrangement for field connections.
Installation and environmental limits
The terminal block is a shielded board with supports that connect it to the front connector of a compatible SCXI module. After connecting the module and terminal block, the rear screws secure the assembly.
NI specifies an operating-temperature range of 0 to 50°C and a storage-temperature range of -20 to 70°C. These limits should be considered when selecting an enclosure or planning the installation environment.
Applications & System Role
The SCXI-1326 serves as the field-wiring interface between external signals and compatible NI SCXI digital I/O modules. It does not perform signal acquisition or switching itself; it provides the terminal connection point, bank isolation, and shielded enclosure for the connected module.
A technical-fit scenario is a digital I/O system using an SCXI-1162 isolated input module, SCXI-1162HV high-voltage input module, SCXI-1163 output module, or SCXI-1163R relay output module. The SCXI-1326 provides the screw-terminal interface for connecting field signals to those modules.
FAQ
What is the NI SCXI-1326?
It is a shielded, high-voltage terminal block with 48 screw terminals for compatible NI SCXI digital I/O modules.
Which SCXI modules does it support?
It supports the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules.
How are its terminals arranged?
The 48 terminals are arranged in eight isolated groups of six. Each group contains VCC, GND, and four channel terminals.
What isolation does it provide?
NI specifies 300 Vrms common-mode isolation between banks and 300 Vrms between banks and earth ground.
Are all VCC and GND terminals used with every module?
No. VCC is not used with the SCXI-1162HV or SCXI-1163R, and GND is not used with the SCXI-1162.
Does the SCXI-1326 acquire or switch signals?
No. It is a terminal block that provides field-wiring connections and bank isolation for a compatible SCXI module.
What are its environmental ratings?
Its operating-temperature range is 0 to 50°C, and its storage-temperature range is -20 to 70°C.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626