Sale!

NORISYS 4-UNIO 4AI4AO Analog I/O Expansion Module

  • Manufacturer: NORIS Automation GmbH
  • Product family: NORISYS 4
  • Model: UNIO 4AI4AO
  • Product type: Universal analog input/output expansion module
  • Analog inputs: 4 channels
  • Analog outputs: 4 channels
  • Platform supply voltage: 24 VDC
  • Signal types: Manufacturer approval documentation identifies current and voltage signal ranges for NORISYS 4 UNIO analog I/O modules.
  • System interface: NORISYS 4 extension bus
  • Typical application: Analog measurement and control in marine automation, process monitoring, and industrial control systems
  • Identification note: The manufacturer’s documentation also references drawing number 091.003.03.511.C for NORISYS 4-UNIO 4AI4AO. Confirm the exact assembly and hardware revision against the nameplate before ordering.
Categories: , , , , SKU: 4-UNIO 4AI4AO Brand:

Description

Key Technical Specifications

Parameter Specification
Manufacturer NORIS Automation GmbH
Product family NORISYS 4
Module designation UNIO 4AI4AO
Analog inputs 4
Analog outputs 4
System supply 24 VDC
Reported system supply range 18–32 VDC
Input signal types Current and voltage; exact ranges depend on configuration
Output signal types Current and voltage; exact ranges depend on configuration
Documented analog ranges 0–20 mA, 4–20 mA, 0–5 V, −5 to +5 V, 0–10 V, and −10 to +10 V
Isolation Manufacturer approval documentation describes galvanic isolation for NORISYS 4 analog I/O
System connection NORISYS 4 extension bus
Operating temperature −25°C to +70°C for the approved NORISYS 4 system configuration
Mounting and enclosure requirements Follow the applicable NORISYS 4 hardware documentation
Manufacturer drawing reference 091.003.03.511.C, parts list, Revision C
Application Industrial and marine control systems

The signal ranges and isolation characteristics are drawn from NORISYS 4 approval documentation covering the analog I/O family. Confirm the individual channel wiring and configuration in the module’s hardware manual before connecting field instruments.

 

Product Introduction

The NORISYS 4-UNIO 4AI4AO provides four analog input channels and four analog output channels within NORIS Automation’s NORISYS 4 control platform. It is intended for systems that must acquire process signals from field instruments and return analog commands to compatible control devices. The module family is documented for marine control applications, including propulsion remote-control systems. For replacement projects, confirm the hardware revision, extension-bus compatibility, signal ranges, and isolation requirements against the original equipment documentation.

 

Installation & Configuration Guide

Verify the hardware

  • Confirm the complete module designation: NORISYS 4-UNIO 4AI4AO.
  • Compare the installed unit’s nameplate, hardware revision, and drawing references.
  • Check compatibility with the existing NORISYS 4 CPU and extension-bus arrangement.
  • Obtain the relevant hardware description and wiring diagrams from NORIS Automation before approving a replacement.

Isolate power

  • Place the controlled equipment in a safe operating state.
  • Isolate the relevant control and field power supplies using the site’s lockout/tagout procedure.
  • Confirm that the module is de-energized before disconnecting wiring or removing the unit.

Check analog signal wiring

  • Identify each input and output channel from the approved wiring diagram.
  • Verify whether each channel is configured for current or voltage operation.
  • Confirm sensor output ranges and actuator input requirements before making connections.
  • Observe the manufacturer’s grounding and galvanic-isolation requirements. Do not assume that all signal terminals share a common reference.

Install and configure the module

  • Install the module using the specified mounting and extension-bus arrangement.
  • Inspect terminal connections and cable routing before restoring power.
  • Configure the controller application for the installed channel allocation and signal types.
  • Do not copy configuration settings from a different UNIO variant without checking the applicable hardware and software revisions.

Test and commission

  • Restore power in accordance with the approved commissioning procedure.
  • Confirm that the controller recognizes the I/O module.
  • Test each analog input using a suitable signal source or known field value.
  • Verify each analog output against the controller command and an appropriate measurement instrument.
  • Document channel assignments, calibration results, and any deviations before returning the equipment to service.

Important: For marine installations, confirm the approval requirements for the specific vessel and application. The ABS product design assessment states that unit certification is required for the covered application, and that individual configurations require approval for the intended installation.

 4-UNIO 4AI4AO

4-UNIO 4AI4AO

Frequently Asked Questions

Q1: What is the NORISYS 4-UNIO 4AI4AO used for?

It provides four analog inputs and four analog outputs for process measurement and control within the NORISYS 4 automation platform.

Q2: How many analog channels does the module have?

It has four analog input channels and four analog output channels.

Q3: Which signal types does it support?

NORISYS 4 approval documentation identifies current ranges including 0–20 mA and 4–20 mA, along with voltage ranges including 0–5 V, −5 to +5 V, 0–10 V, and −10 to +10 V for analog I/O modules. Check the specific channel configuration before wiring.

Q4: What is the operating supply voltage?

The NORISYS 4 platform is specified for 24 VDC. An approval document lists a supply range of 18–32 VDC for the platform; confirm the exact power requirements of the installed module assembly.

Q5: Is the module suitable for marine automation?

The NORISYS 4 platform is documented for marine control applications, including propulsion remote-control systems. Approval of the complete system and its specific installation must be verified for the vessel and classification requirements.

Q6: Can the 4AI4AO module be replaced by a 2AI6AO or 6AI2AO variant?

Not as a direct replacement without engineering review. Those variants have different input/output channel allocations. Confirm application wiring, controller configuration, and the required channel count before considering substitution.

Q7: What information should be provided when sourcing a replacement?

Provide the complete model designation, nameplate photograph, hardware revision, drawing or part-list reference, and the installed NORISYS 4 controller configuration. Request confirmation of signal ranges, terminal assignments, condition, and included accessories from the supplier.