Sale!

Pacific Scientific PC833-001-N-BA PC800 Servo Drive

  • Model: PC833-001-N-BA
  • Brand: Pacific Scientific (Kollmorgen / Danaher Motion)
  • Series: PC800 / PCE800
  • Core Function: Digital control of brushless servo motors
  • Product Type: Digital Brushless Servo Drive
  • Key Specs: 3.6 A RMS continuous, 10.6 A RMS peak, RS-232/485 + Step/Dir interface
  • Condition: New Original / New Surplus
Categories: , , , , SKU: PC833-001-N-BA Brand:

Description

3. Key Technical Specifications

Parameter Value
Manufacturer Pacific Scientific (Kollmorgen)
Model Number PC833-001-N-BA
Series PC800 / PCE800 Brushless Servo Drives
Continuous Current 3.6 A RMS @ 25–40 °C
Peak Current 10.6 A RMS
Input Power 240/240/120 VAC, 3/1/1 PH, 6 A/12 A/12 A RMS
Command Interface RS-232/485, ±V DC, Step/Direction, Indexing
Customization Code Standard Unit
Accessories None
Bandwidth 400 Hz
Key Technology DRDC (Digital Resolver to Digital Conversion) algorithm
Typical Applications Packaging, assembly, semiconductor equipment

4. Product Introduction

The Pacific Scientific PC833-001-N-BA is a compact digital brushless servo drive from the PC800 series. It delivers 3.6 A continuous and 10.6 A peak current and accepts single- or three-phase AC input in the 120/240 VAC range.

The drive supports RS-232/485 serial communication, analog ±V commands, step/direction, and indexing modes. It is used on packaging machines, assembly equipment, and other industrial motion systems that require precise, high-bandwidth servo control with the Pacific Scientific DRDC algorithm.

5. Troubleshooting Quick Reference

Symptom Possible Cause Relevance to this Part Quick Check Method Recommendation
Drive will not enable No AC power or enable signal missing ✅ High Measure AC input and enable input Verify power and control wiring before replacing drive
Overcurrent / fault on enable Motor short or incorrect tuning ✅ High Check motor resistance and insulation Inspect motor and cables; retune or replace drive
No communication Incorrect baud rate or cabling ✅ High Verify RS-232/485 settings and cable integrity Confirm interface configuration; replace if interface failed
Motor runs uncontrolled Feedback or command signal fault ✅ Medium Check resolver/encoder feedback and command source Test feedback device; replace drive if internal fault
Overtemperature fault Insufficient cooling or overload ✅ Medium Measure heatsink temperature and load current Improve airflow; reduce load or replace drive
Intermittent operation Loose connectors or failing unit ✅ High Reseat all connectors and monitor under load Replace drive if problem persists

Always follow lock-out/tag-out and proper ESD practices. If faults remain after checking power, motor, and feedback, provide drive status codes and photos to technical support.

PC833-001-N-BA

PC833-001-N-BA

PC833-001-N-BA

PC833-001-N-BA

PC833-001-N-BA

PC833-001-N-BA

6. Frequently Asked Questions (FAQ)

Q: What motors does the PC833-001-N-BA work with?
A: It is designed for Pacific Scientific / Kollmorgen brushless servo motors compatible with the PC800 series. Confirm motor continuous and peak current ratings match the drive (3.6 A cont / 10.6 A peak).

Q: Does the “-BA” suffix change the function?
A: The -BA indicates a specific revision or configuration of the standard PC833-001-N unit. Core electrical ratings remain the same.

Q: Can it accept both single-phase and three-phase power?
A: Yes. The input is rated for 120/240 VAC single- or three-phase operation within the stated current limits.

Q: What software is used to configure it?
A: Pacific Scientific PC800 series configuration utility (legacy software). Parameter files and tuning should be backed up before replacement.

Q: Why is new-surplus pricing lower than current list?
A: These drives are often available from excess project inventory. They are unused original product, tested, and supplied with a 1-year warranty.

Q: Any critical installation notes?
A: Ensure proper grounding, adequate heatsink airflow, and correct motor/feedback wiring. Match the command interface (RS-232/485, Step/Dir, or analog) to the controller. Incorrect feedback polarity or missing enable signal are common causes of immediate faults.