Description
Core Product Summary
The Pacific Scientific T60-1001-C8-1A is a Type C8 direct-reading cable tensiometer for measuring tension in rigged aircraft control cables. It covers cable diameters from 1/16 inch to 1/4 inch and provides three tension ranges: 10–200 lb, 30–200 lb, and 80–200 lb.
The instrument uses a three-point cable grip, a built-in cable-diameter gauge, a dial pointer lock, and a movable bezel for zero setting. It is supplied with a carrying case and is intended for one-hand operation. For the most consistent readings, the manufacturer recommends taking three to five readings at slightly different locations on the cable and averaging the results.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / series | Pacific Scientific T60 Direct Reading Series |
| Model | T60-1001-C8-1A |
| Product type | Aircraft cable tensiometer |
| Tensiometer type | Type C8 |
| NSN | 6635-00-530-1128 |
| Cable-diameter range | 0.062 in to 0.250 in (1/16 in to 1/4 in) |
| Tension ranges | 10–200 lb, 30–200 lb, and 80–200 lb |
| Cable sizes | 1/16, 3/32, 1/8, 5/32, 3/16, 7/32, and 1/4 in |
| Display | Dial indicating |
| Mounting / measurement method | Clamp-based three-point cable grip |
| Supplied item | Carrying case |
| Construction | Metal |
| Net weight | 1.58 lb (0.72 kg) |
| Shipping weight | 3 lb (1.36 kg) |
| Accuracy | ±5% of indicator value or one minor dial division, whichever is greater, based on averaged dial-scale readings |
| Service manual | T60 Operations and Service Manual, SOP-TN-002 |
Detailed Product Overview
The Pacific Scientific T60-1001-C8-1A is a Type C8 tensiometer from the T60 Direct Reading Series. It is designed to measure cable tension in aircraft control systems while the cables remain in a rigged condition, allowing technicians to verify or adjust tension without removing the cable from the installation.
The instrument accommodates cable diameters from 1/16 inch through 1/4 inch. Its usable tension range depends on cable size: 10–200 lb for 1/16, 3/32, and 1/8 inch cable; 30–200 lb for 5/32 and 3/16 inch cable; and 80–200 lb for 7/32 and 1/4 inch cable. The correct range and cable-size setting must therefore be selected before taking a reading.
The T60-1001-C8-1A uses a positive three-point cable grip intended to keep the instrument securely attached when it hangs freely on a control cable. A built-in cable-diameter gauge helps the operator identify the appropriate setting, while the movable bezel is used to set the dial to the correct cable-size reference.
The dial includes a pointer lock so a reading can be retained when the instrument is positioned where the dial cannot be seen during measurement. The operator can then release the pointer before the next reading. The design supports one-hand operation, including use with gloves or service mittens in cold conditions.
The manufacturer’s instructions specify that the instrument is calibrated for standard multiple-strand aircraft cable: 7 x 7 construction for 1/16 inch and 3/32 inch cable, and 7 x 19 construction for 1/8 inch through 1/4 inch cable. Use on other cable constructions requires correction tables and complete cable-construction information.
Because stranded cable surfaces can cause small reading variations, particularly on 5/32 inch and larger cable, the manufacturer recommends taking three to five readings at slightly different locations and averaging them. The documented accuracy is ±5% of the indicated value or one minor dial division, whichever is greater, when based on averaged dial readings.

T60-1001-C8-1A

T60-1001-C8-1A
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Cable diameter | 1/16 in to 1/4 in (0.062–0.250 in) | Select the correct dial reference for the cable diameter before measurement. |
| Cable construction | 7 x 7 stranding for 1/16 and 3/32 in; 7 x 19 stranding for 1/8 through 1/4 in | Other constructions require correction tables and complete cable specifications. |
| Tension range | 10–200 lb, 30–200 lb, or 80–200 lb | The applicable range depends on cable diameter. |
| Measurement condition | Rigged aircraft control cable | The instrument is intended for tension measurement while the cable remains rigged. |
| Reading method | Direct dial reading with pointer lock | Lock the pointer where the dial is not visible, then read and release it before the next measurement. |
| Supplied accessory | Carrying case | Provides transport and protection for the instrument. |
Dimensions, Mounting & Connection Notes
The T60-1001-C8-1A is a hand-held, clamp-based tensiometer. It is clamped onto the aircraft control cable, and tension is read directly from the dial pointer position.
The instrument has a net weight of 1.58 lb (0.72 kg) and a shipping weight of 3 lb (1.36 kg). It is supplied with a carrying case.
For Type C8 measurements, rotate the knurled rim of the pre-set dial until the pointer aligns with the white square for the cable diameter. For larger cables, two rows of pre-set squares are used: the 125- row for tensions below 125 lb and the 125+ row for tensions above 125 lb.
Exact manufacturer-published overall dimensions are not available for publication.
FAQ
What is the Pacific Scientific T60-1001-C8-1A?
It is a Type C8 direct-reading aircraft cable tensiometer used to measure tension in rigged aircraft control cables.
What cable diameters does it measure?
It measures cable diameters from 1/16 inch to 1/4 inch.
What tension ranges does it cover?
It covers 10–200 lb for 1/16, 3/32, and 1/8 inch cable; 30–200 lb for 5/32 and 3/16 inch cable; and 80–200 lb for 7/32 and 1/4 inch cable.
What cable constructions is it calibrated for?
It is calibrated for 7 x 7 stranded cable in 1/16 and 3/32 inch sizes and 7 x 19 stranded cable from 1/8 inch through 1/4 inch.
How is a reading taken?
Clamp the tensiometer onto the cable, set the dial to the correct cable-size reference, and read the tension directly from the dial pointer.
Why should multiple readings be taken?
Stranded cable surfaces can cause slight reading variations; the manufacturer recommends averaging three to five readings taken at slightly different cable locations.
What accuracy is documented?
Accuracy is ±5% of the indicated value or one minor dial division, whichever is greater, based on averaged dial-scale readings.
What is included with the instrument?
The T60-1001-C8-1A is supplied with a carrying case.
Documented Performance Data
| Metric | Value/range | Test/operating condition |
|---|---|---|
| Tension range | 10–200 lb, 30–200 lb, 80–200 lb | Range depends on cable diameter |
| Accuracy | ±5% of indicator value or one minor dial division, whichever is greater | Based on averaged dial-scale readings |
| Cable-diameter range | 0.062–0.250 in | Type C8 cable tensiometer |
| Net weight | 1.58 lb / 0.72 kg | Instrument weight |
| Shipping weight | 3 lb / 1.36 kg | Instrument with packaging |