Sale!

PRO SC203-100A-002IR-010-01K-05 Vibration Signal Conditioner

The PRO SC203-100A-002IR-010-01K-05 is a vibration signal conditioner from the PRO SC200 series of premium, field-configurable vibration and temperature signal conditioners, built by Connection Technology Center (CTC). In this standard configuration, the unit accepts a 100 mV/g accelerometer input, converts it to a velocity measurement with a full-scale range of 0-2 inches per second RMS, and band-pass filters the signal from 10 Hz to 1000 Hz.

Categories: , , , , SKU: SC203-100A-002IR-010-01K-05 Brand:

Description

Core Product Summary

The PRO SC203-100A-002IR-010-01K-05 is a vibration signal conditioner from the PRO SC200 series of premium, field-configurable vibration and temperature signal conditioners, built by Connection Technology Center (CTC). In this standard configuration, the unit accepts a 100 mV/g accelerometer input, converts it to a velocity measurement with a full-scale range of 0-2 inches per second RMS, and band-pass filters the signal from 10 Hz to 1000 Hz.

Standard outputs are 4-20 mA and 0-5 VDC, allowing vibration levels to be trended and alarmed directly by a PLC, DCS, or SCADA system, while a buffered dynamic output supports connection to vibration data collection equipment for detailed analysis. The module mounts on a 35 mm DIN rail, uses detachable screw-terminal connectors, is powered from a 24-32 VDC unregulated supply, and can be factory or field configured for other input types, scales, filters, and outputs via internal DIP switches.

 

Key Technical Specifications

Parameter Value
Product type Vibration signal conditioner (SC200 series, standard configuration)
Input signal Acceleration, 100 mV/g accelerometer input
Measurement Velocity, RMS
Full-scale range 0-2 inches per second (IPS), RMS
Filter band 10 Hz to 1000 Hz (+3 dB filter range)
Standard outputs 4-20 mA and 0-5 VDC (0-10 VDC selectable)
Dynamic output Buffered output via BNC jack and screw terminals
4-20 mA output signal Vibration and temperature (0-1.2 VDC input); each 4-20 mA output requires an isolated (not shared) common
Sensor excitation 24 VDC, 4 mA DC sensor excitation, selectable On/Off sensor power
Input power 24 to 32 VDC, unregulated, 225 mA maximum
Maximum load resistance 600 Ω
Isolation 1000 VDC
Operating temperature ‘-40 °F to 158 °F (-40 °C to 70 °C)
Humidity 0-95% relative, non-condensing
Mounting 35 mm DIN rail
Terminals Detachable screw terminal connectors, removable plugs with key alignment

 

Detailed Product Overview

The SC203-100A-002IR-010-01K-05 solves a specific integration problem in machine condition monitoring: it converts the dynamic output of a piezoelectric accelerometer into standard process signals that a control system can consume without any vibration-analysis expertise. A 100 mV/g accelerometer signal enters the module, is integrated and band-pass filtered between 10 Hz and 1000 Hz, and leaves as a 0-2 IPS RMS velocity value mapped onto a 4-20 mA loop and a 0-5 VDC signal. Control room personnel can therefore trend and alarm overall vibration on the same infrastructure used for any other process transmitter.

The configuration number itself encodes the engineering choices that matter for replacement and ordering. “SC203” identifies the conditioner model within the SC200 series; “100A” identifies the 100 mV/g acceleration input; “002IR” identifies the 0-2 IPS RMS full-scale range; “010” and “01K” identify the 10 Hz and 1000 Hz filter corners; and “05” identifies the 0-5 VDC standard output. When replacing a unit or specifying a new one, each segment must match the intended measurement range and filter band, because these values define the alarm thresholds the control system sees.

The module is field configurable. Internal DIP switches allow the input signal type, scale values, filtering options, and outputs to be changed on site, and the series also accepts velocity, temperature, and displacement inputs in other configurations. This means a stock of SC200 series hardware can be reconfigured as monitoring requirements change rather than replaced wholesale. The selectable sensor power On/Off option also allows dual-band monitoring, in which multiple signal conditioners are configured with different ranges, units, filters, and outputs for the same machine.

Two wiring practices from the datasheet deserve attention during panel design. Each 4-20 mA output requires an isolated, not shared, common — relevant when a single module transmits both vibration and temperature. And the 4-20 mA loop supports a maximum load resistance of 600 Ω, which constrains loop length and input burden of the receiving analog card. The buffered dynamic output, available on a BNC jack and screw terminals, is what allows a vibration analyst to connect a data collector for frequency analysis when the trended 4-20 mA signal indicates a change, so the same installation serves both operations and reliability teams.

Integration is otherwise straightforward: 24-32 VDC unregulated power (225 mA maximum), 1000 VDC isolation, a -40 to 70 °C operating range, 0-95% non-condensing humidity tolerance, 35 mm DIN rail mounting, and keyed removable plugs that prevent miswiring during installation or module exchange.

SC203-100A-002IR-010-01K-05

SC203-100A-002IR-010-01K-05

SC203-100A-002IR-010-01K-05

SC203-100A-002IR-010-01K-05

Dimensions, Mounting & Connection Notes

Item Verified Value
Mounting 35 mm DIN rail mountable
Terminal connections Screw terminal connectors, detachable; removable plugs with key alignment to avoid miswiring
Dynamic output access BNC jack and screw terminals
Power connection 24 to 32 VDC unregulated input, 225 mA maximum
Operating environment ‘-40 °C to 70 °C; 0-95% RH, non-condensing
Isolation 1000 VDC

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Sensor input 100 mV/g accelerometer (as configured); SC200 series also accepts velocity, temperature, and displacement inputs Confirm input type matches the installed sensor
Sensor excitation 24 VDC, 4 mA DC excitation supplied from the conditioner, selectable On/Off Power can be switched off when the sensor is externally powered or for dual-band setups
Output to control system 4-20 mA to PLC, DCS, or SCADA; selectable 0-5 or 0-10 VDC vibration output Each 4-20 mA output needs an isolated common
Loop load Maximum load resistance 600 Ω Verify against cable resistance and analog-input burden
Dynamic analysis output Buffered output via BNC jack and screw terminals Supports conventional vibration data acquisition equipment
Power supply 24 to 32 VDC, unregulated, 225 mA maximum Standard 24 VDC panel supply is sufficient
Mounting 35 mm DIN rail Detachable, keyed screw-terminal plugs
Configuration Internal DIP switches for field configuration of input, scale, filters, and outputs Also available factory configured
Dual-output sensors SC200 series accepts dual vibration & temperature sensors (e.g., combined units) Transmits overall vibration and temperature as separate 4-20 mA signals

 

FAQ

What is the PRO SC203-100A-002IR-010-01K-05?
It is a vibration signal conditioner from the PRO SC200 series that converts a 100 mV/g accelerometer signal into 4-20 mA and 0-5 VDC process outputs proportional to vibration velocity.

What measurement range and filtering does this configuration provide?
The standard configuration measures velocity over a full-scale range of 0-2 inches per second RMS, band-pass filtered from 10 Hz to 1000 Hz.

Which control systems can receive its output?
The 4-20 mA output is intended for PLC, DCS, and SCADA systems; an additional selectable 0-5 or 0-10 VDC signal is also available for the vibration channel.

Can the unit be reconfigured for other inputs and ranges?
Yes. Internal DIP switches allow field configuration of the input signal, scale values, filtering options, and outputs, and the conditioner can also be factory configured.

What sensor power does the conditioner provide?
It supplies 24 VDC at 4 mA DC excitation to the sensor, with a selectable On/Off option for the sensor power circuit.

What power supply does the SC203-100A-002IR-010-01K-05 require?
It requires 24 to 32 VDC, unregulated, with a maximum consumption of 225 mA.

How is the module mounted and wired?
It mounts on a 35 mm DIN rail with detachable screw-terminal connectors; the removable plugs are keyed to avoid miswiring.

Can vibration analysts still collect dynamic data through this conditioner?
Yes. A buffered dynamic output, available via a BNC jack and screw terminals, supports data collection with conventional vibration data acquisition systems.

 

Documented Performance Data

Metric Value Condition
Full-scale measurement range 0-2 IPS RMS Velocity output from 100 mV/g acceleration input
Filter band 10 Hz to 1000 Hz ‘+3 dB filter range
Maximum loop load resistance 600 Ω 4-20 mA output
Input power consumption 225 mA maximum 24-32 VDC unregulated supply
Isolation 1000 VDC Input/output isolation