Description
Core Product Summary
The PRO SC203-100A-002IR-010-01K-05 is a vibration signal conditioner from the PRO SC200 series of premium, field-configurable vibration and temperature signal conditioners, built by Connection Technology Center (CTC). In this standard configuration, the unit accepts a 100 mV/g accelerometer input, converts it to a velocity measurement with a full-scale range of 0-2 inches per second RMS, and band-pass filters the signal from 10 Hz to 1000 Hz.
Standard outputs are 4-20 mA and 0-5 VDC, allowing vibration levels to be trended and alarmed directly by a PLC, DCS, or SCADA system, while a buffered dynamic output supports connection to vibration data collection equipment for detailed analysis. The module mounts on a 35 mm DIN rail, uses detachable screw-terminal connectors, is powered from a 24-32 VDC unregulated supply, and can be factory or field configured for other input types, scales, filters, and outputs via internal DIP switches.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Vibration signal conditioner (SC200 series, standard configuration) |
| Input signal | Acceleration, 100 mV/g accelerometer input |
| Measurement | Velocity, RMS |
| Full-scale range | 0-2 inches per second (IPS), RMS |
| Filter band | 10 Hz to 1000 Hz (+3 dB filter range) |
| Standard outputs | 4-20 mA and 0-5 VDC (0-10 VDC selectable) |
| Dynamic output | Buffered output via BNC jack and screw terminals |
| 4-20 mA output signal | Vibration and temperature (0-1.2 VDC input); each 4-20 mA output requires an isolated (not shared) common |
| Sensor excitation | 24 VDC, 4 mA DC sensor excitation, selectable On/Off sensor power |
| Input power | 24 to 32 VDC, unregulated, 225 mA maximum |
| Maximum load resistance | 600 Ω |
| Isolation | 1000 VDC |
| Operating temperature | ‘-40 °F to 158 °F (-40 °C to 70 °C) |
| Humidity | 0-95% relative, non-condensing |
| Mounting | 35 mm DIN rail |
| Terminals | Detachable screw terminal connectors, removable plugs with key alignment |
Detailed Product Overview
The SC203-100A-002IR-010-01K-05 solves a specific integration problem in machine condition monitoring: it converts the dynamic output of a piezoelectric accelerometer into standard process signals that a control system can consume without any vibration-analysis expertise. A 100 mV/g accelerometer signal enters the module, is integrated and band-pass filtered between 10 Hz and 1000 Hz, and leaves as a 0-2 IPS RMS velocity value mapped onto a 4-20 mA loop and a 0-5 VDC signal. Control room personnel can therefore trend and alarm overall vibration on the same infrastructure used for any other process transmitter.
The configuration number itself encodes the engineering choices that matter for replacement and ordering. “SC203” identifies the conditioner model within the SC200 series; “100A” identifies the 100 mV/g acceleration input; “002IR” identifies the 0-2 IPS RMS full-scale range; “010” and “01K” identify the 10 Hz and 1000 Hz filter corners; and “05” identifies the 0-5 VDC standard output. When replacing a unit or specifying a new one, each segment must match the intended measurement range and filter band, because these values define the alarm thresholds the control system sees.
The module is field configurable. Internal DIP switches allow the input signal type, scale values, filtering options, and outputs to be changed on site, and the series also accepts velocity, temperature, and displacement inputs in other configurations. This means a stock of SC200 series hardware can be reconfigured as monitoring requirements change rather than replaced wholesale. The selectable sensor power On/Off option also allows dual-band monitoring, in which multiple signal conditioners are configured with different ranges, units, filters, and outputs for the same machine.
Two wiring practices from the datasheet deserve attention during panel design. Each 4-20 mA output requires an isolated, not shared, common — relevant when a single module transmits both vibration and temperature. And the 4-20 mA loop supports a maximum load resistance of 600 Ω, which constrains loop length and input burden of the receiving analog card. The buffered dynamic output, available on a BNC jack and screw terminals, is what allows a vibration analyst to connect a data collector for frequency analysis when the trended 4-20 mA signal indicates a change, so the same installation serves both operations and reliability teams.
Integration is otherwise straightforward: 24-32 VDC unregulated power (225 mA maximum), 1000 VDC isolation, a -40 to 70 °C operating range, 0-95% non-condensing humidity tolerance, 35 mm DIN rail mounting, and keyed removable plugs that prevent miswiring during installation or module exchange.

SC203-100A-002IR-010-01K-05

SC203-100A-002IR-010-01K-05
Dimensions, Mounting & Connection Notes
| Item | Verified Value |
|---|---|
| Mounting | 35 mm DIN rail mountable |
| Terminal connections | Screw terminal connectors, detachable; removable plugs with key alignment to avoid miswiring |
| Dynamic output access | BNC jack and screw terminals |
| Power connection | 24 to 32 VDC unregulated input, 225 mA maximum |
| Operating environment | ‘-40 °C to 70 °C; 0-95% RH, non-condensing |
| Isolation | 1000 VDC |
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Sensor input | 100 mV/g accelerometer (as configured); SC200 series also accepts velocity, temperature, and displacement inputs | Confirm input type matches the installed sensor |
| Sensor excitation | 24 VDC, 4 mA DC excitation supplied from the conditioner, selectable On/Off | Power can be switched off when the sensor is externally powered or for dual-band setups |
| Output to control system | 4-20 mA to PLC, DCS, or SCADA; selectable 0-5 or 0-10 VDC vibration output | Each 4-20 mA output needs an isolated common |
| Loop load | Maximum load resistance 600 Ω | Verify against cable resistance and analog-input burden |
| Dynamic analysis output | Buffered output via BNC jack and screw terminals | Supports conventional vibration data acquisition equipment |
| Power supply | 24 to 32 VDC, unregulated, 225 mA maximum | Standard 24 VDC panel supply is sufficient |
| Mounting | 35 mm DIN rail | Detachable, keyed screw-terminal plugs |
| Configuration | Internal DIP switches for field configuration of input, scale, filters, and outputs | Also available factory configured |
| Dual-output sensors | SC200 series accepts dual vibration & temperature sensors (e.g., combined units) | Transmits overall vibration and temperature as separate 4-20 mA signals |
FAQ
What is the PRO SC203-100A-002IR-010-01K-05?
It is a vibration signal conditioner from the PRO SC200 series that converts a 100 mV/g accelerometer signal into 4-20 mA and 0-5 VDC process outputs proportional to vibration velocity.
What measurement range and filtering does this configuration provide?
The standard configuration measures velocity over a full-scale range of 0-2 inches per second RMS, band-pass filtered from 10 Hz to 1000 Hz.
Which control systems can receive its output?
The 4-20 mA output is intended for PLC, DCS, and SCADA systems; an additional selectable 0-5 or 0-10 VDC signal is also available for the vibration channel.
Can the unit be reconfigured for other inputs and ranges?
Yes. Internal DIP switches allow field configuration of the input signal, scale values, filtering options, and outputs, and the conditioner can also be factory configured.
What sensor power does the conditioner provide?
It supplies 24 VDC at 4 mA DC excitation to the sensor, with a selectable On/Off option for the sensor power circuit.
What power supply does the SC203-100A-002IR-010-01K-05 require?
It requires 24 to 32 VDC, unregulated, with a maximum consumption of 225 mA.
How is the module mounted and wired?
It mounts on a 35 mm DIN rail with detachable screw-terminal connectors; the removable plugs are keyed to avoid miswiring.
Can vibration analysts still collect dynamic data through this conditioner?
Yes. A buffered dynamic output, available via a BNC jack and screw terminals, supports data collection with conventional vibration data acquisition systems.
Documented Performance Data
| Metric | Value | Condition |
|---|---|---|
| Full-scale measurement range | 0-2 IPS RMS | Velocity output from 100 mV/g acceleration input |
| Filter band | 10 Hz to 1000 Hz | ‘+3 dB filter range |
| Maximum loop load resistance | 600 Ω | 4-20 mA output |
| Input power consumption | 225 mA maximum | 24-32 VDC unregulated supply |
| Isolation | 1000 VDC | Input/output isolation |

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626