PROCES-DATA PD1611 Analog Transmitter

Parameter Value
Product type Analog transmitter (intelligent I/O module)
Manufacturer PROCES-DATA A/S, Denmark
Series Module series 1000
Primary function Storing and processing of up to 6 analog measurement signals
Fieldbus interface P-NET
Configuration / programming Channel configuration via Process-Pascal (Pt100 input configuration supported)
Part number 600045
Categories: , , , , SKU: PD1611 Brand:

Description

Core Product Summary

The PROCES-DATA PD1611 is an analog transmitter belonging to PROCES-DATA’s module series 1000, a family of intelligent field and control modules built around the P-NET fieldbus. The module was developed for storing and processing up to 6 analog measurement signals, making it a signal-concentration point where multiple analog field measurements are collected, held, and made available to the control system as structured data. The manufacturer’s part number for this module is 600045.

Because the PD1611 is a P-NET slave-type module, the processed measurement values can be read directly by P-NET masters such as process controllers or PC-based interfaces, each channel treated as an individually addressable data object. Channel configuration — including setup for Pt100 temperature inputs — is handled through Process-Pascal, the programming environment used for PROCES-DATA’s non-COPP modules. For engineers maintaining an existing series 1000 installation, the part number and the 6-signal capacity are the two details that confirm whether a PD1611 matches the slot being replaced.

 

Key Technical Specifications

Parameter Value
Product type Analog transmitter (intelligent I/O module)
Manufacturer PROCES-DATA A/S, Denmark
Series Module series 1000
Primary function Storing and processing of up to 6 analog measurement signals
Fieldbus interface P-NET
Configuration / programming Channel configuration via Process-Pascal (Pt100 input configuration supported)
Part number 600045

 

Detailed Product Overview

The PD1611 occupies a specific niche in PROCES-DATA’s module range: it is one of the analog transmitters of module series 1000, a family of intelligent modules designed around the P-NET fieldbus standard that PROCES-DATA developed and which is now part of the international IEC 61158 fieldbus standard family. Understanding that architecture explains most of the module’s selection criteria.

Its core specification — storing and processing up to 6 analog measurement signals — defines it as a multi-channel signal handler rather than a single-loop device. In practical terms, a controller reading a PD1611 over P-NET does not receive raw wiring-level values; it addresses structured channel data inside the module. This is the P-NET “channel” concept: all data associated with a measurement is held in the module and accessed as an object, which simplifies both integration and later diagnostics at the data level.

Configuration is the second decisive aspect. The PD1611 belongs to PROCES-DATA’s generation of modules programmed in Process-Pascal, and the manufacturer’s controller documentation explicitly covers configuring PD1611 channels for Pt100 temperature inputs through that environment. For an engineer, this means two things: first, commissioning or modifying the module requires the Process-Pascal toolchain, not just a hardware setup routine; second, the module can serve mixed analog duties, including resistance-thermometer measurement, without hardware changes.

Finally, identification deserves emphasis. The PD1610 analog transmitter (part number 600033) and the PD1611 (part number 600045) sit in the same series and share the 6-signal description, so part numbers — not names or appearance — are the reliable discriminator in procurement and spare-part handling. When replacing a module in an existing series 1000 installation, the installation documentation and the physical part marking should be matched against the order number before ordering.

PD1611

PD1611

PD1611

PD1611

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Fieldbus P-NET The module operates as a P-NET network participant; the controlling system must communicate over P-NET.
Configuration software Process-Pascal Channels — including Pt100 inputs — are configured via the Process-Pascal programming environment.
Series / family PROCES-DATA module series 1000 Installation and wiring follow the series 1000 documentation.
Identity check Part No. 600045 Confirm this number when ordering or replacing, to distinguish the PD1611 from similar series 1000 modules.

 

Engineering Selection Highlights

  • Up to 6 analog measurement signals per module — one PD1611 can consolidate several analog sensors into a single P-NET node, which matters when the available node count or cabinet space is limited.
  • P-NET integration — the module communicates over the P-NET fieldbus, so it is selected for existing P-NET installations rather than mixed-protocol cabinets without a gateway.
  • Process-Pascal channel configuration — channels, including Pt100 temperature inputs, are set up through the Process-Pascal environment; the corresponding software tooling must be available for commissioning or reconfiguration.
  • Part number 600045 — this is the manufacturer’s order identifier for the PD1611; verifying it avoids confusion with the closely related PD1610 analog transmitter (part number 600033) in the same series.
  • Series 1000 architecture — the module belongs to PROCES-DATA’s series 1000 family, which defines its mounting and wiring context; system documentation for that series governs installation.

 

Applications & System Role

Within a P-NET-based control architecture, the PD1611 works as an analog signal concentrator. It sits between the field layer — sensors producing analog measurements — and the supervisory layer, where controllers, operator interfaces, or PCs read the stored values over the fieldbus. Its defined job is to store and process up to 6 analog measurement signals and expose them as P-NET data objects, so a supervisory system can poll individual measurements directly rather than wiring each sensor back to a central I/O rack.

The support for Pt100 configuration indicates a fit scenario in temperature-related measurement tasks alongside general analog signal collection. Any deployment decision, however, should follow the system documentation for the specific P-NET installation, since the module’s usefulness depends on the existing network and software environment rather than on standalone capability.

 

FAQ

What is the PROCES-DATA PD1611?
The PD1611 is an analog transmitter from PROCES-DATA, part of the manufacturer’s module series 1000, developed for storing and processing up to 6 analog measurement signals. Its manufacturer part number is 600045.

Which system family does the PD1611 belong to?
It belongs to PROCES-DATA’s module series 1000, a family of intelligent modules designed for integration into P-NET fieldbus networks.

How does the PD1611 communicate with the control system?
The module operates on the P-NET fieldbus, so its stored and processed measurement values are read by P-NET masters such as process controllers or PC interfaces.

How are the module’s channels configured?
Channels are configured through the Process-Pascal programming environment; the manufacturer’s documentation covers configuring PD1611 channels for Pt100 temperature inputs.

How can I confirm I am ordering the correct module?