Description
Core Product Summary
The Reliance Electric 0-57C404-1E is identified as an AutoMax network communications module used in Reliance Electric industrial control systems. The 57C404 product family provides network communication between AutoMax controllers, allowing control and status information to be exchanged across connected network drops.
This module belongs to the communications hardware category rather than the conventional digital or analog I/O range. Its revision designation is important when selecting a replacement because different 57C404 variants support different network functions. Engineers should check the complete hardware identification and existing network configuration before installation.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Reliance Electric |
| Part Number | 0-57C404-1E |
| Product Family | AutoMax |
| Product Type | Network Communications Module |
| Network System | DCS-NET |
| Primary Function | Communication between AutoMax controller drops |
| Network Medium | Coaxial cable system; fiber-optic network configurations are also documented for the 57C404 family |
| Module Architecture | Multibus-based controller module |
Detailed Product Overview
AutoMax Network Communication Function
The Reliance Electric 0-57C404-1E is identified as a network communications component for the AutoMax distributed control architecture.
The 57C404 network module provides a communication path between connected AutoMax controller drops. It exchanges control and status information through network registers, allowing application programs running on different controllers to access shared network data.
This architecture is relevant to distributed industrial control installations where multiple controller racks coordinate machine operations or process functions.
DCS-NET Communication Architecture
The 57C404 family supports the AutoMax DCS-NET network architecture. The documented coaxial installation uses network taps, drop cables, BNC connectors, and terminating loads.
For fiber-optic configurations, the documented supporting components include:
- 57C365 Stand-Alone Fiber-Optic Transceiver
- 57C366 Network Drop Cable
- 57C367 Rack-Mounted Fiber-Optic Transceiver
- 57C368 Fiber-Optic Rack with Power Supply
These accessories belong to the documented network architecture. Their applicability should be checked against the installed network configuration.

0-57C404-1E

0-57C404-1E
Network Revision Considerations
Revision identification is particularly important for the 57C404 family.
The documented compatibility information distinguishes 57C404, 57C404A, 57C404B, and 57C404-1. Network programming is not supported when the 57C404-1 is mixed with the other listed revisions. Although certain versions can coexist on the same network, the network operates according to the limitations of the earliest version.
Consequently, replacement selection should account for the complete module designation and the revisions installed at other network drops.
System Compatibility & Integration Requirements
| Integration Item | Requirement |
|---|---|
| Control platform | Reliance Electric AutoMax |
| Network architecture | DCS-NET |
| Controller communication | AutoMax network drops |
| Network addressing | Drop-number configuration |
| Coaxial network | Network taps, drop cables and terminating loads |
| Fiber-optic network | Requires the appropriate transceiver and cable components |
| Software configuration | Network definitions and register assignments |
Dimensions, Mounting & Connection Notes
The 57C404 family documentation describes a Multibus-based network communications module.
Installation considerations include:
- Check the module’s drop-number configuration before commissioning.
- Inspect network cabling and connectors for physical damage.
- Verify the network termination arrangement.
- Protect the communication cable from abrasion, vibration, and mechanical interference.
- Use appropriate electrostatic discharge precautions when handling the module.
FAQ
1. What is the Reliance Electric 0-57C404-1E?
It is identified as an AutoMax network communications module used in Reliance Electric distributed control systems.
2. What is the primary function of this module?
It exchanges control and status information between connected AutoMax controller drops.
3. Which communication architecture does it use?
It belongs to the AutoMax DCS-NET communication architecture.
4. Can the 57C404 family use fiber-optic communication?
Yes. The documented architecture includes fiber-optic transceivers and associated connection components.
5. Why is the module revision important?
Different 57C404 revisions have different network capabilities. In particular, the documented 57C404-1 version does not support network programming available in later versions.
6. What should engineers check before replacement?
Check the complete part number, module revision, network drop configuration, controller hardware, and communication network architecture.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626