Description
Core Product Summary (Brand / Model / Key Attributes)
The Schneider Electric Foxboro TNA1-TU01-SH is a specialized Field Termination Assembly (FTA) engineered for Foxboro I/A Series and EcoStruxure Foxboro DCS hardware architectures. Serving as the physical interface layer between field instrumentation cabling and process I/O modules, this unit provides organized, high-density termination points for analog and discrete field signals in process control environments.
Designed with integrated shield termination points (designated by the “-SH” suffix), the TNA1-TU01-SH provides dedicated earth ground pathways for shielded twisted-pair signal cables, minimizing electromagnetic interference (EMI) and signal noise in sensitive measuring loops. Featuring factory-applied conformal coating (“TNA” prefix series), the assembly protects terminal connections and internal trace paths against corrosive gases, high humidity, and airborne contaminants typical of chemical processing, power generation, and refining facilities.
Key Technical Specifications
| Specification Parameter | Technical Value / Standard |
| Manufacturer | Schneider Electric / Foxboro |
| Model / Part Number | TNA1-TU01-SH |
| Product Category | Field Termination Assembly (FTA) / Terminal Block |
| System Compatibility | Foxboro I/A Series / EcoStruxure Foxboro DCS I/O |
| Environmental Protection | Conformal Coated Assembly (TNA Series) |
| Shield Grounding | Dedicated Shield Termination Points (-SH Variant) |
| Connection Type | Screw Clamp / Compression Terminals |
| Field Wire Capacity | Accepts 14 AWG to 26 AWG solid or stranded wire |
| Maximum Operating Voltage | 30 VDC / 125 VAC Nominal (Channel dependent) |
| Current Rating | Up to 2A per channel / terminal point |
| Operating Temperature | -20°C to +70°C (-4°F to +158°F) |
| Operating Humidity | 5% to 95% RH (non-condensing) |
| Mounting Style | Standard DIN Rail / Baseplate Assembly Mounting |
| Enclosure Protection | IP20 (Open-frame cabinet assembly) |
Detailed Product Overview
The Schneider Electric Foxboro TNA1-TU01-SH provides a reliable wiring interface within Foxboro distributed control system cabinets. By routing field instrument lines to standardized cable headers, it eliminates direct point-to-point field wiring at the I/O module level, simplifying panel design, commissioning, and system maintenance.
The TNA1-TU01-SH integrates dedicated shield grounding connections for each field channel. Maintaining clean, isolated shield paths prevents ground loops and guards analog 4–20 mA or low-voltage digital signals against high-frequency electrical noise common in industrial motor control environments.
The factory conformal coating protects fine trace lines and terminal contact points from Class G3 harsh environmental exposures, such as sulfur-bearing atmospheres in oil refineries and wastewater treatment plants. Standard screw-clamp terminals ensure vibration-resistant cable retention and consistent long-term electrical contact.

TNA1-TU01-SH

TNA1-TU01-SH
Engineering Selection Highlights
- Factory Conformal Coating (TNA Series): Shields board surfaces and terminal traces against corrosive atmospheric contaminants and high humidity.
- Dedicated Shield Grounding (-SH): Built-in shield connection points simplify ground loop management and improve noise rejection on analog loops.
- High-Density Channel Interface: Organizes multiple field signal pairs into a single compact terminal assembly, optimizing cabinet space.
- Pre-Engineered System Cabling: Interfaces with Foxboro I/O baseplates via pre-fabricated system cables, reducing field wiring time and potential miswiring errors.
- Vibration-Resistant Screw Terminals: Provides robust mechanical clamping for stranded or solid copper field conductors.
System Compatibility & Integration Requirements
| System Component / Layer | Compatibility / Integration Requirement | Practical Note |
| Control System Architecture | Foxboro I/A Series & EcoStruxure Foxboro DCS | Connects directly to compatible Foxboro FBM / I/O modules. |
| Interface Cables | Standard Foxboro multi-conductor system cables | Links the FTA terminal block to designated baseplate slots. |
| Field Cabling | 14 to 26 AWG shielded copper conductors | Ensure cable shields are landed on designated -SH terminals. |
| Cabinet Mounting | Standard DIN Rail or vertical baseplate mounting | Position to allow adequate wire duct routing clearance. |
Dimensions, Mounting & Connection Notes
- Mounting Configuration: Mounts onto standard DIN rails or baseplate tracks inside control enclosures.
- Wiring Termination: Screw-clamp compression terminals accept stripped wire ends or crimped wire ferrules.
- Shield Grounding Practice: Connect field instrument cable shields strictly to the dedicated shield terminals on the assembly to maintain single-point grounding integrity.
- Cabinet Clearance: Ensure sufficient space above and below the terminal strip for wire routing ducts and proper cable strain relief.
FAQ
What is the primary function of the Foxboro TNA1-TU01-SH?
The TNA1-TU01-SH is a Field Termination Assembly (FTA) used in Foxboro DCS systems to connect field instrument wiring to system I/O modules.
What does the “-SH” suffix indicate on the TNA1-TU01-SH?
The “-SH” suffix indicates that the assembly includes dedicated shield termination points for landing the shields of shielded instrument cables.
What does the “TNA” prefix represent in Foxboro hardware?
The “TNA” prefix denotes that the printed circuit assembly features factory-applied conformal coating for corrosion protection in harsh environments.
Does the TNA1-TU01-SH mount on standard DIN rail?
Yes, it is designed for snap-on mounting on standard DIN rails or dedicated Foxboro baseplate tracks inside control cabinets.
What wire gauges are supported by the screw terminals?
The screw-clamp terminals accommodate standard industrial field wiring ranging from 14 AWG to 26 AWG.
Verification & Troubleshooting Notes
- Shield Continuity Verification: Periodically test continuity between shield terminals and the main cabinet earth ground bar to ensure effective noise suppression.
- Terminal Torque Inspection: Check screw terminal tightness during routine maintenance to prevent loose connections caused by thermal cycling or cabinet vibration.
- Visual Inspection of Coating: Inspect the board surface for physical damage or contaminant buildup if installed in unconditioned or high-humidity environments.
- Channel Continuity Testing: Use a multimeter to verify field wiring signals directly at the terminal screws without disconnecting the multi-conductor interface cable from the I/O baseplate.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626