Description
Core Product Summary
The SEW UFP11A-00 is associated with the UFP11A PROFIBUS DP-V1 fieldbus interface used in SEW drive automation systems. The interface connects a PROFIBUS DP-V1 network to the SBus communication system, allowing compatible SEW inverters to exchange process data with a higher-level controller.
The UFP11A architecture provides a communication link between the PROFIBUS network and multiple inverters connected through SBus. This arrangement allows a PROFIBUS master to communicate with connected drive equipment through a centralized fieldbus interface. When identifying this component for maintenance or procurement, the complete type designation and hardware nameplate should be checked against the installed equipment.
Key Technical Specifications
| Parameter | Technical Information |
|---|---|
| Manufacturer | SEW-EURODRIVE |
| Product designation | UFP11A |
| Product type | PROFIBUS DP-V1 fieldbus interface |
| Primary function | PROFIBUS DP-V1 to SBus communication |
| PROFIBUS protocol | PROFIBUS DP-V1 |
| SBus communication protocol | MOVILINK |
| Maximum connected inverters | 8 |
| PROFIBUS connection | 9-pin Sub-D connector |
| SBus connection | Separable screw-type terminals |
| External supply | 18–30 V DC |
| Current consumption | Maximum 200 mA at 24 V DC |
| Startup and diagnostic software | MOVITOOLS V2.70 or later |
| Parameter interface | RS-485 |
Detailed Product Overview
PROFIBUS DP-V1 Communication Architecture
The UFP11A serves as a fieldbus gateway between a PROFIBUS DP-V1 master and SEW drive inverters connected through the SBus interface.
In this architecture, the higher-level automation controller communicates with the UFP11A over PROFIBUS. The gateway then exchanges data with the connected inverters through SBus. This arrangement provides a centralized communication point for coordinating multiple drive units within an industrial control system.
The interface supports up to eight connected inverters. This capability is relevant when designing drive networks in which several inverter units need to communicate with one PROFIBUS master.
PROFIBUS and SBus Integration
The two communication interfaces serve different roles within the system.
- PROFIBUS DP-V1: Connects the fieldbus interface to the higher-level controller.
- SBus: Provides communication between the UFP11A and connected SEW inverters.
- MOVILINK: Defines the communication protocol used on the SBus side.
The PROFIBUS connection uses a 9-pin Sub-D connector, while the SBus connection uses separable screw-type terminals. These different connection arrangements should be considered when preparing control cabinet wiring and maintenance procedures.
Power Supply and Startup Requirements
The UFP11A requires an external DC supply within the documented 18–30 V range. Its stated maximum current consumption is 200 mA at 24 V DC.
Startup and diagnostic operations can be performed using MOVITOOLS V2.70 or later. The interface also provides an RS-485 parameter-setting and diagnostic connection.
For commissioning, engineers should consider the PROFIBUS station address, SBus wiring, bus termination, connected inverter configuration, and communication status indicators.
Engineering and Maintenance Considerations
The UFP11A occupies an important position in the communication path between the controller and the drive network. A communication fault may affect data exchange with multiple connected inverters rather than only one drive.
During troubleshooting, engineers should distinguish between PROFIBUS communication faults, SBus communication problems, external power issues, and inverter configuration errors.
The RUN, BUS-F, and SYS-F indicators provide status information that helps narrow down communication and system faults.

UFP11A-00

UFP11A-00
System Compatibility & Integration Requirements
| Item / Dependency | Compatibility or Requirement | Practical Note |
|---|---|---|
| Fieldbus network | PROFIBUS DP-V1 | Connects to a compatible PROFIBUS master |
| Drive communication | SEW SBus | Connects compatible SEW inverters |
| Inverter network | Up to 8 inverters | Check SBus configuration and network termination |
| Communication protocol | MOVILINK | Used for SBus communication |
| Power supply | 18–30 V DC | External supply required |
| PROFIBUS connector | 9-pin Sub-D | Check connector wiring |
| SBus connector | Separable screw-type terminals | Check terminal wiring |
| Startup software | MOVITOOLS V2.70 or later | Used for configuration and diagnostics |
| GSD configuration | SEWA6004.GSD | DP-V1 project configuration |
FAQ
1. What is the SEW -00?
The UFP11A is a PROFIBUS DP-V1 fieldbus interface designed to connect SEW drive inverters to a PROFIBUS network through SBus.
2. What is the primary function of the UFP11A?
It provides communication between a PROFIBUS DP-V1 master and compatible SEW inverters connected through the SBus interface.
3. Which communication protocols does the UFP11A use?
It uses PROFIBUS DP-V1 on the fieldbus side and MOVILINK on the SBus side.
4. How many inverters can connect to the UFP11A?
The documented interface supports up to eight inverters through SBus.
5. What power supply does the UFP11A require?
The documented external supply range is 18–30 V DC, with maximum current consumption of 200 mA at 24 V DC.
6. Which software is used to configure the UFP11A?
MOVITOOLS V2.70 or later is specified for startup and diagnostic operations.
7. What connector is used for PROFIBUS communication?
The PROFIBUS interface uses a 9-pin Sub-D connector.
8. What should engineers check when replacing a UFP11A-00?
Check the complete product designation, connection arrangement, external power supply, PROFIBUS configuration, SBus wiring, and connected inverter configuration before installation.