Description
Core Product Summary (Brand / Model / Key Attributes)
The SICK WS/WE24-2B230 (Part Number: 1017861) is a compact through-beam photoelectric sensor set operating within the SICK W24-2 sensor family. Consisting of an optical sender (WS24-2D230, Part No. 2021156) and receiver (WE24-2B230, Part No. 2021160), this pair provides object detection across an operating sensing distance of up to 50 meters, reaching a maximum limit of 60 meters.
Operating on a nominal supply voltage of 10 to 30 V DC, the WS/WE24-2B230 features selectable NPN or PNP switching outputs combined with selectable light/dark switching modes. The sensor pair utilizes a visible red LED light source (660 nm) with an approximate 1° dispersion angle. Housed in a zinc die-cast IP67 enclosure, the unit features a terminal connection compartment with a rotatable M16 screw gland for integration into industrial conveyor and material handling lines.
Key Technical Specifications
| Parameter | Specification |
| Manufacturer | SICK AG |
| Model / Type Code | WS/WE24-2B230 |
| Part Number (System) | 1017861 |
| Individual Components | Sender: WS24-2D230 (2021156) / Receiver: WE24-2B230 (2021160) |
| Sensor Principle | Through-beam photoelectric sensor (Sender and Receiver set) |
| Sensing Range Max / Nominal | 0 m to 60 m max / 0 m to 50 m operating range |
| Supply Voltage (UB) | 10 V DC to 30 V DC |
| Power Consumption (Sender) | 50 mA (without load) |
| Output Type & Mode | Selectable NPN / PNP; Selectable Light / Dark switching |
| Max Output Current (Imax) | ≤ 100 mA |
| Response Time / Frequency | ≤ 500 µs response time / 1,000 Hz switching frequency |
| Light Source & Type | Visible red LED (660 nm wavelength) |
| Adjustment Options | Sensitivity potentiometer trimmer, NPN/PNP selector, Light/Dark selector |
| Housing Dimensions (W x H x D) | 27 mm × 87.5 mm × 65 mm |
| Enclosure Rating | IP67 |
| Connection Type | Terminal connection compartment with M16 gland (rotatable by 90°) |
Detailed Product Overview
The SICK WS/WE24-2B230 is an industrial through-beam photoelectric sensor system engineered for long-range object detection and presence verification in harsh factory environments. By separating the optical transmitter and receiver into distinct zinc die-cast housings, through-beam arrangements ensure high operational reserve, enabling reliable object detection even in the presence of dust, airborne particles, or optical alignment drift.
Equipped with a visible red LED operating at 660 nm, the sensor produces a light spot diameter of approximately 700 mm at a 50-meter distance. Internal selector switches behind the housing cover allow field technicians to choose between NPN or PNP output logic as well as Light-ON or Dark-ON switching modes. The receiver includes a potentiometer trimmer for sensitivity calibration and an LED signal strength indicator to streamline physical optical alignment over long sensing spans.
This sensor pair is deployed across automated logistics systems, packaging machinery, outdoor entry gates, conveyor lines, and heavy manufacturing plants requiring reliable long-distance light-barrier sensing.

WS/WE24-2B230

WS/WE24-2B230
Engineering Selection Highlights
- 60 Meter Max Sensing Range: Long optical reach permits installation across wide conveyor spans, access gates, and large equipment bays.
- Selectable Output Logic: Integrated NPN/PNP and Light/Dark selector switches reduce inventory requirements by matching multiple PLC input specifications.
- High Switching Speed: Fast 500 µs response time and 1,000 Hz switching frequency support high-speed material handling and fast object counting.
- Rugged IP67 Zinc Die-Cast Housing: Metal enclosure withstands mechanical impact and washdown conditions in tough industrial environments.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Operating Power | 10 V DC to 30 V DC supply voltage | Ensure power supply ripple does not exceed < 5 Vpp tolerances. |
| PLC Input Compatibility | NPN or PNP digital discrete inputs | Set the internal NPN/PNP selector switch to match controller input card logic. |
| Signal Cabling | Standard industrial control cable via M16 gland | Terminate conductors into screw terminal chamber inside the sensor housing. |
| Mounting Hardware | M5 threaded mounting holes (through-hole and 6 mm deep) | Compatible with SICK BEF-WG-W24 mounting brackets (Part No. 4026324). |
Dimensions, Mounting & Connection Notes
- Dimensions: Each unit measures 27 mm wide × 87.5 mm high × 65 mm deep.
- Mounting Features: Equipped with M5 threaded mounting holes (6 mm depth) and M5 through-holes for flexible structural mounting.
- Wiring Connection: Terminal connection chamber with an M16 screw gland. Connection block can be rotated by 90° for optimal cable routing.
- Alignment Aids: Built-in alignment sights and rear-mounted LED signal strength indicators assist in optical alignment between sender and receiver units.
- Environmental Limits: Rated for operation in ambient temperatures from –40 °C to +60 °C (–40 °F to +140 °F).
FAQ
What is included in the SICK WS/WE24-2B230 set?
The WS/WE24-2B230 set (Part Number: 1017861) includes both the optical sender unit (WS24-2D230) and the optical receiver unit (WE24-2B230).
What is the maximum sensing distance for this sensor?
The sensor pair has a maximum sensing range of 60 meters (with an operating sensing range of 0 to 50 meters).
Is the switching output NPN or PNP?
The sensor features an internal changeover switch allowing the user to select either NPN or PNP output operation.
How is the electrical cable connected to the housing?
It uses a terminal connection compartment accessed via an M16 screw cable gland, which can be rotated by 90° for flexible cable positioning.
What is the ingress protection rating of the housing?
The housing is constructed from zinc die-cast metal and is rated to IP67 ingress protection standards.
Verification & Troubleshooting Notes
- Optical Alignment Inspection: Check the rear LED signal strength indicator while adjusting the sender/receiver alignment sight to achieve maximum signal reception strength.
- Verify Internal Switch Settings: Open the terminal cover and confirm that the NPN/PNP switch and Light/Dark selector switch match the PLC input configuration.
- Power Supply Voltage Check: Measure supply terminals with a multimeter to verify voltage remains within the specified 10 to 30 V DC range under load.
- Terminal Chamber Sealing: Ensure the terminal cover gasket is properly seated and the M16 gland is tightened to preserve IP67 environmental sealing.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626