Sale!

Toshiba PS693 Power Supply Module for nv Series Controller

Parameter Value
Model PS693
Manufacturer / Series Toshiba, Unified Controller nv series (type1 light / type2 light); Integrated Controller V Series 2000
Function AC power supply module for the controller unit
Rated input voltage 100 – 240 VAC
Allowable input voltage range 85 – 264 VAC
Rated frequency 50 / 60 Hz
Allowable frequency range 47 – 53 Hz / 57 – 63 Hz
Permitted instantaneous power failure 10 ms or less
Main output 5 V DC, 7 A
Grounding Class D grounding (dedicated ground)
Power-cycle requirement At least one second must elapse between power-off and the next power-on
Categories: , , , , SKU: PS693 Brand:

Description

Core Product Summary

The Toshiba PS693 is the dedicated AC power supply module for the Unified Controller nv series, used in the controller units of the nv type1 light and type2 light configurations as well as the Integrated Controller V Series 2000 platform. It converts a 100–240 VAC mains input into the internal low-voltage supplies that feed the controller and I/O modules on the rack.

The module accepts a rated input of 100–240 VAC (allowable range 85–264 VAC) at 50/60 Hz, and it rides through instantaneous power failures of 10 ms or less. Its main output is a 5 V / 7 A supply. Toshiba’s controller documentation designates the PS693 as the required power module for these controller units — other power modules are not to be substituted — and specifies dedicated Class D grounding for the module.

 

Key Technical Specifications

Parameter Value
Model PS693
Manufacturer / Series Toshiba, Unified Controller nv series (type1 light / type2 light); Integrated Controller V Series 2000
Function AC power supply module for the controller unit
Rated input voltage 100 – 240 VAC
Allowable input voltage range 85 – 264 VAC
Rated frequency 50 / 60 Hz
Allowable frequency range 47 – 53 Hz / 57 – 63 Hz
Permitted instantaneous power failure 10 ms or less
Main output 5 V DC, 7 A
Grounding Class D grounding (dedicated ground)
Power-cycle requirement At least one second must elapse between power-off and the next power-on

 

Engineering Selection Highlights

  • Dedicated module status → Toshiba’s instruction manual states that no power module other than the PS693 may be used for the nv series controller unit, making exact-model matching mandatory rather than optional when replacing a failed supply.
  • 85–264 VAC allowable input range → the module operates on both 100 V and 200 V class mains without selection or rewinding, so one part number covers installations in different supply regions.
  • 10 ms ride-through → instantaneous mains dips of 10 ms or less do not interrupt the controller; longer outages will drop the controller unit, which matters when the upstream distribution has slow transfer switching.
  • 5 V / 7 A output → the module’s capacity is matched to the controller unit’s internal load; adding or changing rack modules must stay within the documented rack configuration.
  • Class D dedicated grounding → the module requires a dedicated ground connection; sharing a ground with other equipment is a documented deviation from the installation conditions.
  • One-second power-off interval → after removing power, at least one second must pass before reapplying it, or the module may not start properly; this is a mandatory note for maintenance procedures.
  • Migration role → in Toshiba’s documented T2-series to nv-series migration, the T2 power supply PS261 is converted to the PS693, so the module is the designated successor part in that migration path.

 

Detailed Product Overview

The PS693 exists because Toshiba’s nv series controller architecture separates the power conversion function from the processing function. The controller modules, bus interfaces, and I/O modules run on internal low-voltage supplies, and the PS693 is the component that produces the main 5 V / 7 A rail from the plant’s AC mains. This division means a power-side fault can be repaired by exchanging one module without disturbing the controller configuration.

Electrically, the module is built for a wide input envelope: 100–240 VAC nominal, with a documented allowable range of 85–264 VAC and a frequency tolerance of 47–53 / 57–63 Hz. In procurement terms this means a single part number serves both 100 V-class and 200 V-class sites, and the module tolerates the steady-state voltage sag common on shared industrial distribution circuits. The specified 10 ms ride-through covers the brief dips caused by contactor switching or transfer events; the controller documentation treats failures longer than 10 ms as a full power loss.

Two operational rules from the instruction manual deserve attention in maintenance planning. First, the module is mandatory equipment: the documentation explicitly prohibits using any power module other than the PS693 with these controller units, so substitution with a look-alike supply is not an accepted practice. Second, the power-cycle rule — at least one second between power-off and power-on — is a startup requirement, not a suggestion; violating it can leave the module failing to start or malfunctioning, which can look like a hardware defect during troubleshooting.

The module also appears in Toshiba’s documented migration path from the T2-series platform to the nv controller, where the older PS261 power supply is converted to the PS693. Sites performing that migration therefore need the PS693 as part of the conversion, not merely as a failure spare.

PS693

PS693

PS693

PS693

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Controller family Unified Controller nv series controller units (type1 light, type2 light); Integrated Controller V Series 2000 The PS693 is the power module specified for these controller units.
Substitution rule No other power module may be used for the controller unit Documented as mandatory in the nv series instruction manual.
Mounting location Controller rack; duplexed power configurations supported with rear mounting in extended slots The type2 light hardware manual shows PS693 in single and duplex (rear-mounted) power configurations.
Input supply 100–240 VAC (85–264 VAC), 50/60 Hz (47–53/57–63 Hz) Compatible with both 100 V and 200 V class mains.
Ride-through Instantaneous power failure of 10 ms or less permitted Longer interruptions stop the controller unit.
Grounding Class D grounding (dedicated) Required for the controller installation.
Power cycling Minimum one second between power-off and power-on Prevents startup faults or malfunction.
Migration path T2 series power supply PS261 converts to PS693 in nv type1 light migration Documented in the nv series hardware manual’s migration procedures.

 

Dimensions, Mounting & Connection Notes

The PS693 installs into the power supply slot of the nv series controller rack; in duplexed power configurations documented for the type2 light controller, a second power module is rear-mounted in the extended slot of the chassis. The module requires Class D (dedicated) grounding, and Toshiba recommends grounding the controller unit separately from the power system and bringing two or more controller units to a single grounding point. When servicing, observe the mandatory interval of at least one second between power-off and the next power-on.

 

Applications & System Role

Within a Toshiba Unified Controller nv system, the PS693 occupies the power supply position in the controller rack. It does not process I/O or execute logic; its role is to convert the facility’s single-phase AC mains into the regulated internal supply on which the controller module (for example the PUM21 in type2 light systems), the serial bus interface modules, and the rack’s I/O modules depend. If this module fails, the entire controller unit stops, which makes it a common spare part for nv and V Series 2000 installations maintained in industrial and infrastructure control cabinets.

 

FAQ

What is the Toshiba PS693?
It is the AC-input power supply module used in Toshiba Unified Controller nv series controller units, including the type1 light and type2 light configurations.

What input voltage does it accept?
It is rated for 100–240 VAC with an allowable range of 85–264 VAC, at 50/60 Hz (allowable 47–53 / 57–63 Hz).

What output does it provide?
Its main output is a 5 V / 7 A internal supply for the controller rack.

Can a different power module be used in an nv controller unit?
No — Toshiba’s instruction manual specifies that a power module other than the PS693 must not be used for these controller units.

How does it handle power dips?
Instantaneous power failures of 10 ms or less are permitted without interrupting operation; longer interruptions stop the controller.

Does it need a dedicated ground?
Yes, the module requires Class D grounding, and Toshiba recommends grounding the controller unit separately from the power system.

Why does it matter when migrating from a T2 system?
In the documented T2-to-nv migration, the T2-series power supply PS261 is converted to the PS693 as part of moving to the nv type1 light controller.

Is there a power-cycling restriction?
Yes — at least one second must elapse between power-off and the next power-on, otherwise the module may not start properly or may malfunction.