Description
Core Product Summary
The Traco Power TIS 600-148 is a 600-watt switch-mode power supply for DIN-rail mounting from the TIS industrial power supply series. It delivers a 48 VDC output at 12 A from a selectable 115/230 VAC input, in a construction designed for industrial process systems and machine installations.
The unit accepts an AC input within 93–132 VAC or 187–264 VAC ranges, selected for the 115 or 230 V line. It is designed for very low output ripple and noise, EMI compliance with EN 61000-6-3 and EN 61000-6-4, and operation over −25 °C to +70 °C. It snaps onto standard DIN rails or mounts on a chassis. Within the TIS 600 family, function-module variants extend the standard unit: a RED version adds a redundancy module with true current sharing for N+1 systems, and a SIG version adds a signal module with AC power-fail and power-good signals plus external On/Off control. The series carries worldwide safety approvals, including acceptance for Class I, Division 2 locations, and a 3-year product warranty.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Switch-mode industrial power supply, DIN-rail mount |
| Series | Traco Power TIS series, 50–600 W |
| Output power | 600 W |
| Output voltage / current | 48 VDC / 12 A |
| Input voltage | Selectable 115/230 VAC (93–132 VAC / 187–264 VAC ranges) |
| Ripple and noise | Very low (series design characteristic) |
| EMI compliance | EN 61000-6-3, EN 61000-6-4 |
| Operating temperature range | −25 °C to +70 °C |
| Mounting | Snap-on DIN-rail mounting or chassis mount |
| Safety approvals | Worldwide approvals, including Class I, Division 2 locations |
| Function variants | TIS 600-148 RED (redundancy module, N+1 true current sharing); TIS 600-148 SIG (signal module: AC power-fail, power good, external On/Off) |
| Warranty | 3-year product warranty |
| Approximate weight | 2000 g (shipping weight) |
Detailed Product Overview
The TIS series was designed specifically for industrial process systems and machine tools, where the supply must tolerate rough electrical environments — wide input swings, conducted noise, and continuous thermal load — rather than the benign conditions assumed by commercial-grade units. The TIS 600-148 is the 48 V member of the 600 W tier of this series, a voltage class typically used for higher-power PLC I/O, drives auxiliary circuits, and 48 V control distribution.
The selectable 115/230 VAC input deserves attention during panel engineering. Input range selection must be set for the installed line voltage before commissioning; the wide 93–132 VAC and 187–264 VAC ranges then cover the sag and swell conditions common on industrial distribution networks, so rated output is maintained through disturbances that would force a narrow-range supply into dropout or derating.
Output quality is a series design focus: low ripple and noise reduce the burden on downstream 48 V electronics, and EMI emissions comply with EN 61000-6-3 and EN 61000-6-4, covering both residential/light-industrial and heavy-industrial emission limits. That matters when the panel must pass a CE EMC review without additional filtering hardware.
The family’s system functions are what distinguish the TIS line from a plain rectifier supply. The RED version implements N+1 redundancy with true current sharing, meaning two supplies actively share the load so that the failure of one does not interrupt the 48 V bus. The SIG version provides monitoring contacts — AC power-fail and power good — plus external On/Off control, which lets the control system supervise the supply and sequence power-up. A DC-UPS module enabling battery-backed operation is available within the TIS series for installations that require ride-through of AC outages.
Mechanically, the unit is built for cabinet integration: it snaps onto standard DIN rails or can be chassis-mounted, and the −25 °C to +70 °C operating range covers unheated enclosures and high-density cabinets alike, provided the surrounding enclosure keeps within this envelope.

TIS 600-148

TIS 600-148
Dimensions, Mounting & Connection Notes
- The unit mounts by snap-on attachment to a standard DIN rail, or alternatively by chassis mounting.
- Input is 115/230 VAC selectable; the applicable input range (93–132 VAC or 187–264 VAC) must be set for the installed line before operation.
- Rated output parameters apply at full load.
- Shipping weight is approximately 2000 g; consult the manufacturer’s datasheet for detailed dimensional drawings for panel cutout and clearance planning.
- The operating temperature range is −25 °C to +70 °C; install so that the enclosure environment preserves this range under full-load thermal conditions.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Input supply | 115 or 230 VAC line, selected for the installation | Selectable input must be configured before commissioning; rated parameters obtained at full load |
| Output load | 48 VDC loads up to 12 A / 600 W | Confirm load inrush behavior at switch-on |
| Mounting | Standard DIN rail or chassis | Snap-on mounting for cabinet installation |
| Parallel / redundant operation | TIS 600-148 RED variant with redundancy module, N+1 true current sharing | Order the RED version when redundancy is required |
| Monitoring / control | TIS 600-148 SIG variant: AC power-fail, power good, external On/Off | Order the SIG version when supervision by the control system is required |
| DC-UPS extension | DC-UPS module available within the TIS series | For battery-backed ride-through applications |
| EMC environment | Emissions per EN 61000-6-3 / EN 61000-6-4 | Supports CE EMC panel compliance |
| Location approvals | Worldwide safety approvals incl. Class I, Division 2 | Verify the approval relevant to the installation site |
| Thermal planning | −25 °C to +70 °C operating range | Ensure enclosure environment stays within limits at full load |
FAQ
What is the Traco Power TIS 600-148?
It is a 600 W industrial switch-mode power supply for DIN-rail mounting, delivering 48 VDC at 12 A from a selectable 115/230 VAC input.
What input voltage does it accept?
A selectable 115/230 VAC input, with operational ranges of 93–132 VAC and 187–264 VAC respectively.
What output does it provide?
A regulated 48 VDC output at 12 A, designed with very low ripple and noise.
How is it mounted?
By snap-on attachment to a standard DIN rail, or by chassis mounting.
What is the difference between the standard, RED, and SIG versions?
The standard unit provides basic power conversion. The RED version adds a redundancy module with true current sharing for N+1 systems; the SIG version adds a signal module with AC power-fail and power-good signals plus external On/Off control.
Can it be used in a redundant system?
Yes — the RED variant is intended for N+1 redundant configurations with active current sharing between units.
Is battery backup available?
A DC-UPS module for battery-backed operation is available within the TIS series of function modules.
What environmental limits apply?
Operating temperature range is −25 °C to +70 °C; emissions comply with EN 61000-6-3 and EN 61000-6-4.
What approvals does it carry?
Worldwide safety approvals including acceptance for Class I, Division 2 locations, and a 3-year product warranty from the manufacturer.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626