Sale!

Vibro-Meter VM600 RPS600 System Rack Power Supply Module

Parameter Specification
Manufacturer Vibro-Meter (Meggitt Sensing Systems)
Model Designation VM600 RPS600
Part Number Family 200-582-xxx-xxx (e.g., 200-582-000-011)
System Platform VM600 Machinery Protection System
Module Type System Power Supply Unit (PSU)
Input Voltage Options AC Input: 100–240 V AC nominal (47–63 Hz) / DC Input: 110–220 V DC nominal (variant dependent)
Output DC Bus Rails Regulated internal DC voltages (+5V DC, ±12V DC, +24V DC field sensor supply rails)
Output Power Capacity Up to 300 W continuous total output power
Categories: , , , , SKU: VM600 RPS6 Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The Vibro-Meter VM600 RPS600 (Meggitt) is the central power supply unit designed for the VM600 machinery protection and condition monitoring platform. Installed into dedicated power slots of VM600 19-inch rack mainframes (such as the ABE601 and ABE602), this module converts industrial AC or DC primary input power into regulated internal DC voltages required to operate all front processing modules, rear I/O cards, and internal backplane communications.

The RPS600 delivers multiple DC output rails across the VM600 VMEbus backplane, powering protection cards (such as the MPC4), communication controllers (such as the CMC16/CPUx), and associated rear terminal modules (IOC4T, IOCN, IOC16T). Supporting redundant power configurations, two RPS600 modules can be installed in a single rack to provide continuous, dual-path power sharing and seamless failover for critical turbomachinery protection applications.

 

Key Technical Specifications

Parameter Specification
Manufacturer Vibro-Meter (Meggitt Sensing Systems)
Model Designation VM600 RPS600
Part Number Family 200-582-xxx-xxx (e.g., 200-582-000-011)
System Platform VM600 Machinery Protection System
Module Type System Power Supply Unit (PSU)
Input Voltage Options AC Input: 100–240 V AC nominal (47–63 Hz) / DC Input: 110–220 V DC nominal (variant dependent)
Output DC Bus Rails Regulated internal DC voltages (+5V DC, ±12V DC, +24V DC field sensor supply rails)
Output Power Capacity Up to 300 W continuous total output power
Redundancy Support 1:1 active power sharing / redundant configuration support
Front-Panel Status Diagnostic LEDs for AC/DC input health and internal DC bus output status
Form Factor Front-mounting 6U Eurocard module format
Operating Temperature Range -20°C to +65°C (-4°F to +149°F)
Storage Temperature Range -40°C to +85°C (-40°F to +185°F)
Relative Humidity 0% to 95% non-condensing
Environmental Approvals CE marked, hazardous location / SIL system options available

 

Detailed Product Overview

The Vibro-Meter VM600 RPS600 power supply module forms the electrical foundation of the VM600 machinery protection and condition monitoring ecosystem. By transforming raw plant electrical power into stable, filtered DC voltages, the unit ensures uninterrupted operation for critical vibration monitoring, speed monitoring, and automatic machinery shutdown loops.

Designed for high-reliability industrial environments, the RPS600 features high efficiency, low ripple, and wide input voltage tolerances to withstand voltage dips and noise spikes common in power plants, oil refineries, and industrial processing facilities. Internal power distribution lines supply logic power for microprocessors, high-speed A/D converters, and relay coils, as well as clean DC excitation power for field-connected eddy-current proximity probes and accelerometers.

In mission-critical monitoring setups, VM600 19-inch racks accommodate two RPS600 modules in a 1+1 redundant configuration. When dual power supplies are installed, load-sharing circuitry balances power delivery between both units. If one input power line fails or a power supply encounters a fault, the remaining RPS600 seamlessly assumes full system load without causing system resets, false alarms, or interruption to active machinery trip protection loops.

VM600 RPS6

VM600 RPS6

VM600 RPS6

VM600 RPS6

Engineering Selection Highlights

  • High-Capacity Power Conversion: Converts wide-range AC or DC primary plant power into clean, regulated DC power rails for up to 300 W system load.
  • 1:1 Redundant Architecture: Supports dual-module installations for active load sharing and zero-delay power failover.
  • Integral Field Transducer Power: Supplies regulated DC voltages across the backplane to power field proximity probes, velocity sensors, and transmitters.
  • Front-Panel Health Diagnostics: High-visibility LEDs display real-time status of incoming mains power and internal DC voltage rails.
  • Standard Eurocard Form Factor: Slides directly into dedicated power supply slots on VM600 ABE60x series 19-inch rack enclosures.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Mainframe Chassis Vibro-Meter VM600 ABE601 / ABE602 19″ Racks Installs into designated PSU slots on the left or right side of the rack
Companion Modules All VM600 Front Processing Cards & Rear I/O Modules Powers MPC4, CMC16, IOC4T, IOCN, and associated system cards via the backplane
Redundant Operation Second RPS600 Power Supply Module Requires dual power slots wired to independent mains AC/DC power sources
Input Power Wiring Hardwired AC or DC power feed Lands on designated power input connectors on the rear rack plane

 

Dimensions, Mounting & Connection Notes

  • Form Factor: Standard 6U Eurocard format.
  • Mounting Method: Slides into the front panel of a VM600 19-inch rack and is secured with top and bottom captive thumbscrews.
  • Input Wiring Landing: Mains AC or DC power cables connect to the dedicated rear power input block corresponding to the RPS600 slot.
  • Cooling Clearance: Maintain standard vertical cabinet ventilation space above and below the 6U VM600 rack to ensure proper convection airflow through the power module heatsinks.
  • Chassis Grounding: Functional safety ground connects via the rack frame and rear earthing stud to ensure safe operation and electrical noise suppression.

 

FAQ

What is the function of the Vibro-Meter VM600 RPS600 module?

The RPS600 is the primary power supply unit for the VM600 rack system, converting AC or DC plant power into regulated internal voltages for all cards and field sensors.

Can a VM600 rack use redundant power supplies?

Yes, VM600 ABE60x racks support dual RPS600 modules configured for 1:1 active power redundancy and automatic load sharing.

What happens if one power supply fails in a redundant configuration?

If one RPS600 loses input power or fails, the second unit automatically assumes 100% of the system load without interrupting machinery protection or monitoring functions.

How do I check if the power supply is operating correctly?

The front faceplate features LED indicators that display the status of incoming power supplies and internal DC output rails.

 

Verification & Troubleshooting Notes

1

Inspect Front-Panel Power LEDs

1 min

1.Inspect Front-Panel Power LEDs:1 min.

Observe the LED status indicators on the front panel of the RPS600 module upon energizing primary power. Verification: The green power/health LEDs illuminate solid green, confirming that incoming power is present and all internal DC bus voltages (+5V, ±12V, +24V) are within normal operating tolerances.

2

Verify Primary Input Voltage

2 min

2.Verify Primary Input Voltage:2 min.

If the status LEDs remain dark, use a calibrated multimeter to check the AC or DC voltage at the rear power input terminal block for the corresponding RPS600 slot. Verification: Measured line voltage falls within the specified input range (e.g., 100–240 V AC or specified DC range).

3

Check Card Alignment & Retaining Screws

2 min

3.Check Card Alignment & Retaining Screws:2 min.

If power is present at the rear terminal but the module fails to initialize, disconnect input power, loosen the captive thumbscrews, re-seat the RPS600 module firmly into the backplane connector, and hand-tighten the screws. Verification: The card faceplate sits flush against the rack frame and multi-pin power connectors make complete contact.

4

Test Redundant Power Failover

3 min

4.Test Redundant Power Failover:3 min.

In dual-RPS600 configurations, switch off the circuit breaker for one power feed while monitoring active machinery protection channels. Verification: The remaining RPS600 maintains system operation without channel interruption, system reboot, or false trip generation.