Description
Core Product Summary
The Wasco UHP169-31L2B-X1601 (also cataloged as UHP169-31L2B-X/1601) is an ultra-high purity (UHP) stainless steel vacuum switch specifically engineered for semiconductor manufacturing equipment, gas distribution panels, and high-purity chemical delivery systems. Factory-calibrated for a set point of 575 Torr (approx. 760 mbar), this precision vacuum switch provides critical system interlock and pressure monitoring functions for specialized vacuum and gas handling applications.
Belonging to Wasco’s UHP160 Series, the UHP169-31L2B-X1601 features an all-welded 316L stainless steel wetted construction with no internal elastomers or O-rings, completely eliminating potential outgassing and contamination paths. Manufactured and packaged in an ISO Class 5 (Class 100) cleanroom, the switch undergoes 100% helium leak testing to ensure leak-tight performance (\le 1 \times 10^{-9} std cc/sec per SEMI F1) in high-purity, corrosive, and toxic gas environments.
Key Technical Specifications
| Parameter | Specification |
| Manufacturer | Wasco, Inc. |
| Model / Part Number | UHP169-31L2B-X1601 (UHP169-31L2B-X/1601) |
| Product Series | UHP160 / UHP169 Series |
| Product Type | Ultra-High Purity (UHP) Vacuum Pressure Switch |
| Nominal Set Point | 575 Torr (approx. 760 mbar) |
| Construction | All-welded 316L Stainless Steel (No internal O-rings or elastomers) |
| Internal Surface Finish | \le 5\,\muin R_a (Electropolished UHP grade surface) |
| Helium Leak Rate | \le 1 \times 10^{-9} std cc/sec Helium (per SEMI F1 standard) |
| Cleanroom Assembly | ISO Class 5 (Class 100) Cleanroom Manufactured & Packaged |
| Target Application | Semiconductor Gas Cabinets, IGS Gas Panels, Etch & Deposition Systems |
Detailed Product Overview
The Wasco UHP169-31L2B-X1601 is designed to meet the extreme cleanliness and reliability standards demanded by advanced semiconductor processing and specialty gas distribution equipment. In automated gas boxes, mass flow control (MFC) blocks, and process chambers, pressure and vacuum switches act as vital safety interlocks. The UHP169-31L2B-X1601 detects precise vacuum-to-ambient pressure transitions around 575 Torr to verify process purging, vacuum draw, or manifold seal integrity.
All-Welded UHP Construction
Traditional pressure switches utilize rubber seals or O-rings that can degrade, outgas, or react with aggressive semiconductor process gases (such as F_2, Cl_2, or NH_3). The UHP169-31L2B-X1601 eliminates all non-metallic wetted materials by deploying a hermetically sealed, all-welded stainless steel sensor element. The internal flow path is polished to a ultra-smooth surface finish (\le 5\,\muin R_a) to prevent particle entrapment and minimize gas moisture absorption.
Semiconductor Quality Standards
Every UHP169 switch is built within an ISO Class 5 cleanroom and undergoes stringent quality verifications. The switch is helium leak-tested to SEMI F1 criteria, ensuring that neither external atmosphere can ingress into sub-atmospheric process lines nor hazardous process media can leak into the cabinet space.

UHP169-31L2B-X1601

UHP169-31L2B-X1601
Engineering Selection Highlights
- 575 Torr Set Point: Factory-set for accurate sub-atmospheric sensing and vacuum verification in gas delivery manifolds.
- Elastomer-Free Wetted Path: All-welded 316L stainless steel design prevents outgassing, particle generation, and chemical breakdown.
- \le 5\,\muin R_a Internal Finish: Ultra-smooth internal surfaces allow rapid gas purging and minimize moisture retention.
- ISO Class 5 Cleanroom Packaged: Double-bagged in cleanroom packaging to maintain high purity up to point-of-use installation.
- SEMI F1 Leak Integrity: Tested to \le 1 \times 10^{-9} std cc/sec helium leak rates for maximum process safety.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Gas System Infrastructure | Semiconductor Gas Panels, IGS Gas Boxes, Vacuum Lines | Select face-seal (VCR compatible) or welded tube stub process fittings. |
| Process Media | Inert, flammable, toxic, and corrosive semiconductor gases | Compatible with aggressive gases due to all-stainless steel wetted design. |
| Electrical Interface | Standard low-voltage logic / PLC input loop | Connect to control system digital input cards for interlock and alarm processing. |
| Installation Standards | Ultra-High Purity (UHP) piping standards | Maintain cleanroom handling procedures during unwrapping and installation. |
Dimensions, Mounting & Connection Notes
- Cleanroom Unpacking: Open the outer protective packaging outside the clean bay; remove the inner sealed bag only within a cleanroom environment or under a laminar flow hood.
- Fitting Connections: Align process port connections carefully to avoid galling threads or damaging delicate metal face-seal gaskets. Follow standard torque guidelines for face-seal (VCR-style) fittings.
- Orientation: Can be mounted in any orientation without affecting set point accuracy, provided physical clearance is maintained for electrical connectors.
- Electrical Termination: Ensure proper strain relief on electrical lead wires to prevent mechanical stress on the internal switch contacts or housing pass-through.
FAQ
What is the primary application of the Wasco UHP169-31L2B-X1601?
It is used in semiconductor manufacturing tools, gas cabinets, and gas panels as an ultra-high purity vacuum switch to monitor vacuum integrity and signal pressure set points around 575 Torr.
Does the UHP169-31L2B-X1601 contain any internal O-rings?
No. The UHP160/169 series features an all-welded stainless steel construction with zero internal elastomers or O-rings to prevent process contamination.
What is the helium leak rating for this switch?
All Wasco UHP series switches are 100% helium leak tested to \le 1 \times 10^{-9} std cc/sec Helium in accordance with the SEMI F1 standard.
Verification & Troubleshooting Notes
- False Switching / No Switch Actuation:
- Measure line pressure using an independent calibrated vacuum gauge to confirm system pressure actually passes the 575 Torr threshold.
- Check electrical wiring continuity across the switch contacts using a multimeter to confirm state change when pressure transitions across set point.
- Helium Leak Test Alarm:
- Inspect the metal face-seal gasket at the process port for scratches or debris.
- Verify that mating fitting hex nuts are torqued to manufacturer specifications.
- Signal Noise or Contact Bounce:
- Ensure electrical cable shielding is grounded at the PLC / controller end to prevent EMI from nearby high-power equipment or RF generators.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626