Description
Core Product Summary
The Whitman Controls W117V-3H-F52M-X is an ultra pure stainless steel vacuum switch from the W117V series. It features all-welded stainless steel interiors that are helium leak checked to a rate of 4 × 10⁻⁹ Std CC/Sec.
This switch is intended for high-purity vacuum applications such as silicon wafer processing and medical devices where contamination must be minimized. The 3H sensor code provides a set-point range covering decreasing vacuum from 1.6 to 27.0 inHg and increasing vacuum from 2.7 to 28.2 inHg, with a maximum system vacuum of 29.9 inHg and zero PSIG maximum system pressure. It operates across a temperature range of –65 °F to +225 °F (–54 °C to +107 °C) and is available with SPDT contacts rated to 5 A.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Ultra pure stainless steel vacuum switch |
| Series | W117V |
| Sensor code | 3H |
| Set-point range (decreasing) | 1.6 to 27.0 inHg |
| Set-point range (increasing) | 2.7 to 28.2 inHg |
| Maximum system vacuum | 29.9 inHg |
| Maximum system pressure | 0 PSIG |
| Temperature range | –65 °F to +225 °F (–54 °C to +107 °C) |
| Electrical rating | 5 A maximum (SPDT) |
| Sensor construction | Electron-beam welded, helium leak tested |
| Wetted materials | Capsule: 17-7 PH stainless; Fitting: 303 SS |
| Standard process connection | ⅛-27 NPT male |
| Approximate weight | 3 oz |
| Cycling limit (3H) | Not to exceed 60 cycles per minute |
Engineering Selection Highlights
- All-welded stainless steel construction with helium leak testing to 4 × 10⁻⁹ Std CC/Sec supports high-purity vacuum systems where particulate or outgassing contamination must be avoided.
- 3H sensor code delivers a broad adjustable set-point window suitable for medium-vacuum monitoring applications.
- Maximum system pressure limited to 0 PSIG confirms suitability for pure vacuum service only.
- Wide operating temperature range of –65 °F to +225 °F accommodates both low- and elevated-temperature process environments.
- Compact capsule design and ⅛ NPT (or optional VCR) process connection allow installation in space-constrained high-purity manifolds.
- SPDT contacts rated to 5 A provide direct switching capability for control circuits or interlocks.
- Cycling limit of 60 CPM for the 3H sensor defines the maximum switching frequency for reliable long-term operation.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Process media | Compatible with materials listed (17-7 PH capsule, 303 SS fitting) | Confirm media compatibility before installation |
| Process connection | ⅛-27 NPT male (standard); optional ¼ VCR male or ¼-18 NPT | Use wrench on hex only; do not torque switch body |
| Electrical interface | F52M configuration (specific connector or lead style) | Verify pinout and wire length against application drawing |
| Set-point adjustment | Field adjustable via adjusting ring | Loosen ring, rotate switch body, re-tighten |
| System pressure | Vacuum only (0 PSIG maximum) | Not suitable for positive pressure service |
| Environmental limits | –65 °F to +225 °F | Observe temperature limits for reliable operation |
Dimensions, Mounting & Connection Notes
The switch is a compact cylindrical design with a nominal diameter of approximately 1⅛ in and overall length dependent on the electrical interface. Process connection is via the standard ⅛-27 NPT male thread (or optional VCR/NPT variants). Mount using a wrench on the hex portion of the fitting only; do not apply torque to the switch body. Electrical connection follows the F52M interface specified in the part number. Set-point adjustment is performed by loosening the adjusting ring, rotating the electrical switch body, and re-securing the ring.
Detailed Product Overview
The Whitman Controls W117V-3H-F52M-X belongs to the W117V series of ultra pure stainless steel vacuum switches. These devices are constructed with fully welded stainless steel interiors that undergo helium leak testing to a stringent rate of 4 × 10⁻⁹ Std CC/Sec, ensuring suitability for processes in which even minute impurities are unacceptable.
The sensing element is an electron-beam-welded 17-7 PH stainless steel capsule. The process fitting is 303 stainless steel, with the standard connection being ⅛-27 NPT male; optional ¼ VCR male and ¼-18 NPT male fittings are available. The 3H sensor code defines a set-point capability covering decreasing vacuum from 1.6 to 27.0 inHg and increasing vacuum from 2.7 to 28.2 inHg, with a maximum system vacuum rating of 29.9 inHg and a maximum system pressure of 0 PSIG.
Electrical contacts are SPDT and rated to 5 A. The F52M portion of the part number specifies a particular electrical interface configuration. Operating temperature extends from –65 °F to +225 °F (–54 °C to +107 °C). Cycling is limited to 60 cycles per minute for the 3H sensor.
Installation requires care to avoid over-torquing the body and to ensure media compatibility with the wetted materials. Set-point adjustment is performed by means of an external adjusting ring. Because the design is optimized for pure vacuum service, it is not intended for positive-pressure applications.
The combination of welded construction, helium leak integrity, broad set-point range, and compact size makes the W117V-3H-F52M-X appropriate for high-purity vacuum monitoring and control in semiconductor, medical, and related process equipment.

W117V-3H-F52M-X

W117V-3H-F52M-X
Applications & System Role
The W117V-3H-F52M-X serves as a high-purity vacuum sensing and switching element in processes that cannot tolerate contamination. It is commonly applied in semiconductor equipment such as silicon wafer ovens, medical devices requiring ultra-clean vacuum, and other systems where helium-leak-tight stainless construction is mandatory.
In the control architecture the switch provides a discrete SPDT output that changes state at the selected vacuum set point, enabling interlocks, alarms, or sequencing logic based on vacuum level.
FAQ
What is the Whitman Controls -3H–X?
It is an ultra pure stainless steel vacuum switch with all-welded construction and helium leak testing for high-purity applications.
What set-point range does the 3H sensor provide?
Decreasing vacuum 1.6 to 27.0 inHg and increasing vacuum 2.7 to 28.2 inHg.
What is the maximum system pressure rating?
0 PSIG (vacuum service only).
What temperature range can the switch operate in?
–65 °F to +225 °F (–54 °C to +107 °C).
What electrical rating is available?
SPDT contacts rated to 5 A maximum.
What process connections are offered?
Standard ⅛-27 NPT male; optional ¼ VCR male and ¼-18 NPT male.
How is the set point adjusted?
By loosening the adjusting ring, rotating the electrical switch body, and re-tightening the ring.