Description
Core Product Summary (Brand / Model / Key Attributes)
The SST-ESR2-CPX-P (frequently associated with Molex Woodhead / SST network technology for Rockwell Automation environments) is an in-chassis communication module designed specifically for Allen-Bradley CompactLogix programmable automation controller systems. This “Plus” version module functions as a robust gateway, enabling seamless data exchange between CompactLogix controllers and external Modbus network architectures.
The hardware features a versatile physical interface layout, including one 10/100 Mbps RJ45 Ethernet port supporting Modbus TCP/UDP and two configurable RS-232/422/485 serial ports supporting Modbus RTU/ASCII. Configuration is handled through the dedicated SST Configuration Console utility, with files typically stored on an integrated MicroSD card slot for simplified deployment and maintenance. Front-panel diagnostic LEDs provide real-time status visibility for power, communication state, link speed, and fault identification.
Key Technical Specifications
| Technical Parameter | Verified Specification |
| Brand / Manufacturer | Molex Woodhead / SST (for Allen-Bradley CompactLogix) |
| Model / Order Number | SST-ESR2-CPX-P (Plus Version) |
| Product Type | In-Chassis Ethernet and Serial Network Communication Module |
| System Platform Compatibility | Allen-Bradley CompactLogix backplane architecture |
| Ethernet Communication Port | 1 x 10/100 Mbit/s RJ-45 port (Modbus TCP/UDP) |
| Serial Communication Ports | 2 x configurable RS-232 / RS-422 / RS-485 ports up to 115.2 Kbit/s (Modbus RTU/ASCII) |
| Data Capacity | Up to 32,000 words for input and output |
| Command Capacity | Up to 256 commands per port |
| Configuration Tool | SST Configuration Console via MicroSD card storage |
| Diagnostics & Status | Integrated LED indicators (OK, STATE, LINK, SPEED, SD, FAULT) |
Detailed Product Overview
The SST-ESR2-CPX-P module serves as a specialized networking bridge designed to integrate third-party Modbus devices—such as drives, meters, sensors, and secondary PLCs—into an Allen-Bradley CompactLogix control environment. By slotting directly into the controller chassis, it eliminates the need for standalone protocol converters or complex gateway wiring.
The module manages intensive data mapping efficiently, supporting high-capacity data storage (up to 32,000 words for inputs and outputs) and handling up to 256 user-defined commands per serial/Ethernet port. Fast cyclic data refreshing allows I/O data to synchronize smoothly across the backplane structure. Comprehensive onboard diagnostic LEDs and a MicroSD configuration framework ensure that technicians can track communication health or swap out hardware modules rapidly during maintenance cycles.

SST-ESR2-CPX-P

SST-ESR2-CPX-P
Engineering Selection Highlights
- Direct In-Chassis Integration → Mounts straight into the CompactLogix backplane system, saving cabinet space over external gateway units.
- Dual Protocol Support → Combines Ethernet-based Modbus TCP/UDP with dual multi-mode serial ports (RS-232/422/485) for mixed device topologies.
- High Command Capacity → Supports up to 256 commands per port and large word-data register blocks to manage complex multi-device networks.
- MicroSD Card Configuration → Simplifies setup duplication, project archiving, and field replacement using removable flash storage.
- Comprehensive Status Monitoring → On-board LED array gives immediate visual feedback on network traffic, link speeds, card status, and error states.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Controller Platform | Allen-Bradley CompactLogix controller hardware | Designed specifically for in-chassis slot placement in CompactLogix systems. |
| Software Tooling | SST Configuration Console application | Required to build, configure, and download the communication mapping files. |
| Memory Card | MicroSD card | Used to store module configuration files for fast recovery or hardware swaps. |
| Physical Cabling | Standard RJ45 Ethernet patch cables & D-Sub / RJ45 serial connectors | Match cable shielding and termination rules to industrial EMC guidelines. |
Dimensions, Mounting & Connection Notes
- Module Form Factor: Standard in-chassis single-slot module width for CompactLogix installations.
- Weight: Approximately 2.00 lbs (0.91 kg) packaged / modular unit weight varies by revision.
- Port Connections: Front accessibility for 1x RJ45 Ethernet port and serial connection channels.
- Environmental Consideration: Designed for standard industrial control enclosure layouts; adhere to local temperature limits and installation altitude restrictions (rated up to 1000 m standard operation).
FAQ
What is the SST-ESR2-CPX-P module?
It is an in-chassis network communication interface module built to connect Allen-Bradley CompactLogix controllers with Modbus TCP/UDP and Modbus RTU/ASCII networks.
Which controller platforms are compatible with this module?
It is engineered specifically for use within the Allen-Bradley CompactLogix platform series.
What communication ports are available on the module?
The module features one 10/100 Mbps RJ45 Ethernet port and two configurable serial interface ports supporting RS-232, RS-422, and RS-485 standards.
How is the module configured?
Configuration is performed using the software-based SST Configuration Console, with configuration files stored onto an onboard MicroSD card.
What is the maximum data capacity supported?
The module supports up to 32,000 words for input data and 32,000 words for output data, with up to 256 individual commands per port.
Verification & Troubleshooting Notes
- Diagnostic LED Checks: Observe the status LEDs (OK, STATE, LINK, SPEED, SD, and FAULT) on the front panel to quickly isolate hardware health, memory card detection, or network timeout triggers.
- Configuration Verification: Ensure that the configuration file loaded onto the MicroSD card matches the exact firmware revision and network address map of connected field slaves.
- Serial Wiring Integrity: When utilizing RS-422/485 serial connections, verify proper polarization, termination resistor usage, and ground continuity to prevent intermittent packet loss.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626