Description
Core Product Summary
Applicom PCU1500S7 is an intelligent PROFIBUS network interface card for connecting PC-based automation applications to Siemens SIMATIC S7 communications networks. Part of the applicom communication-card range, it supports S7/MPI Master, PPI/PPI+ Master, and Send/Receive on FDL. Its onboard processor handles communication-protocol processing, providing a dedicated communication interface for HMI, SCADA, and custom software applications.
The card uses a universal PCI 3.3 V / 5 V interface with PCI-X compatibility. One female 9-pin D-Sub port provides RS485 communication with 500 V galvanic isolation and transmission rates from 9.6 kbps to 1.5 Mbps. The associated applicom software package includes configuration and diagnostic tools, OPC DA servers, and development libraries. Molex identifies this model with order number 112011-0006 and engineering number APP-PS7-PCU-C.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Product family | applicom PROFIBUS network interface cards |
| Model | PCU1500S7 |
| Product function | PC-based communication interface for PROFIBUS SIMATIC S7 |
| Molex order number | 112011-0006 |
| Engineering number | APP-PS7-PCU-C |
| Host interface | Universal PCI, 3.3 V / 5 V; PCI-X compatible |
| Communication ports | 1 PROFIBUS port |
| Connector | Female 9-pin D-Sub |
| Electrical interface | RS485 |
| Galvanic isolation | 500 V |
| Transmission rate | 9.6 kbps to 1.5 Mbps |
| Supported protocols | S7/MPI Master; PPI/PPI+ Master; Send/Receive on FDL |
| Onboard processor | AMD SC520 |
| Power consumption | 5.5 W |
| Communication indicators | TX and RX LEDs |
These specifications apply to the PCU1500S7 configuration within the applicom PROFIBUS card range.
Engineering Selection Highlights
- Universal PCI 3.3 V / 5 V interface → select a host computer with the corresponding PCI expansion slot; the card is not a PCI Express board.
- S7/MPI Master support → matches PC applications requiring access to SIMATIC S7 communications through the S7/MPI protocol.
- Protocol set includes PPI/PPI+ Master and Send/Receive on FDL → selection must consider the actual communication service required, rather than the PROFIBUS connector alone.
- Maximum transmission rate of 1.5 Mbps → the intended network speed must remain within the card’s documented range.
- One isolated RS485 port with a female 9-pin D-Sub connector → network cabling must match this electrical interface and connector arrangement.
- OPC DA and development-library interfaces → integration can use the supplied data-server architecture or a custom application interface, depending on the software design.

PCU1500S7

PCU1500S7
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Host expansion bus | Universal PCI 3.3 V / 5 V; PCI-X compatible | Use a host with the matching PCI bus interface. |
| S7 communication | S7/MPI Master | Provides the PC-side communication role for S7/MPI connections. |
| Additional protocol services | PPI/PPI+ Master; Send/Receive on FDL | Match the selected service to the connected equipment and application. |
| Network connection | One isolated RS485 PROFIBUS port; female 9-pin D-Sub | Requires a mating network connector and compatible cabling. |
| Network speed | 9.6 kbps to 1.5 Mbps | Configure communication within this range. |
| Engineering tools | applicom configuration console; test and diagnostic tools | Supports interface configuration and communication checks. |
| Data-server interfaces | OPC DA 3.0 and 2.05; Wonderware DAServer; SuiteLink/FastDDE | Match the application’s supported data interface to the selected server. |
The listed hardware, protocol, and software relationships are documented for the applicom PROFIBUS package covering PCU1500S7.
Dimensions, Mounting & Connection Notes
- Installation format: internal PCI expansion card using a universal 3.3 V / 5 V PCI interface.
- Network connection: one female 9-pin D-Sub PROFIBUS connector.
- Electrical interface: RS485 with 500 V galvanic isolation.
- Local communication indication: TX and RX LEDs.
- Card power consumption: 5.5 W.
Detailed Product Overview
Separate the host interface from the network interface
Selecting PCU1500S7 involves two independent interfaces. On the computer side, the card uses universal PCI with 3.3 V / 5 V support and PCI-X compatibility. On the equipment side, it provides an isolated RS485 PROFIBUS connection. Both must match the intended installation: a suitable network connection does not compensate for an incompatible computer expansion bus.
The onboard AMD SC520 processor executes communication-protocol management and processing. This architecture places network tasks on the interface card instead of relying entirely on host-side software to perform them. The associated applicom tools provide configuration, testing, and diagnostics for establishing and checking the communication path.
Select by protocol, not just by connector
The model’s S7 designation identifies a specific protocol configuration. PCU1500S7 supports S7/MPI Master, PPI/PPI+ Master, and Send/Receive on FDL. Its documented protocol list does not include PROFIBUS DP-V0 Master Class-1 and Class-2, which the same product documentation assigns to the PFB configuration. Consequently, a requirement for a PROFIBUS interface should be resolved into the actual protocol service before this card is selected.
The physical port operates from 9.6 kbps to 1.5 Mbps. That upper limit is material when matching an existing network configuration; the PROFIBUS name alone should not be interpreted as support for higher transmission rates.
Align the application’s data interface
The applicom package provides more than a hardware driver. Its software interfaces include OPC DA, Wonderware data-server connections, and development libraries. These support different integration paths: an HMI or SCADA application can use a supported data server, while custom software can use the available programming libraries. The chosen path must match the application’s interface requirements.
For procurement identification, the model PCU1500S7 is associated with Molex order number 112011-0006 and engineering number APP-PS7-PCU-C. These identifiers distinguish the universal PCI S7 card from the other bus formats and protocol configurations in the same product range.
Applications & System Role
PCU1500S7 occupies the communication-interface layer between a PC application and a supported industrial network. It provides the hardware port and onboard protocol processing needed for the PC to exchange data using S7/MPI, PPI/PPI+, or FDL messaging. It is a communication card rather than a field I/O module.
Documented application contexts for the applicom communication platform include HMI, SCADA, and custom automation software. For PCU1500S7, a corresponding technical-fit scenario is a PC-based supervision or data-acquisition application that requires the card’s supported S7 communication services over an RS485 network. This describes its architectural role, not a claim about a particular installation.
FAQ
What is Applicom PCU1500S7?
Applicom PCU1500S7 is an intelligent universal PCI network interface card for connecting PC-based applications to PROFIBUS SIMATIC S7 communications. It includes onboard protocol processing and one RS485 network port.
Which protocols does PCU1500S7 support?
It supports S7/MPI Master, PPI/PPI+ Master, and Send/Receive on FDL. These are the documented services for the S7 card configuration.
Does PCU1500S7 use PCI or PCI Express?
PCU1500S7 uses universal PCI with 3.3 V / 5 V support and PCI-X compatibility. It is not the PCI Express configuration.
What is its communication-speed range?
Its documented transmission range is 9.6 kbps to 1.5 Mbps over the RS485 PROFIBUS interface.
What network connector does the card provide?
The card provides one female 9-pin D-Sub connector. The RS485 interface has 500 V galvanic isolation, with TX and RX LEDs for communication indication.
Can it serve as a PROFIBUS DP-V0 master?
PROFIBUS DP-V0 Master is not part of the documented PCU1500S7 protocol set. The product documentation assigns DP-V0 Master Class-1 and Class-2 to the PFB card configuration, while PCU1500S7 provides S7/MPI, PPI/PPI+, and FDL messaging services.
What ordering identifiers correspond to PCU1500S7?
The Molex order number is 112011-0006, and the engineering number is APP-PS7-PCU-C. Both identify the PCU1500S7 PCI network interface card for PROFIBUS SIMATIC S7.

WhatsApp: +86 16626708626
Email: