Description
Core Product Summary (Brand / Model / Key Attributes)
The Bender W4-S140 (Part Number: B911734) is a high-sensitivity measuring current transformer engineered for residual current monitoring (RCM) and insulation fault location (EDS) systems. Operating within the Bender W-S series measuring transformer portfolio, this toroidal unit converts AC residual currents into evaluable signals for downstream Bender evaluation devices.
Featuring a 140 mm inner diameter, the W4-S140 accommodates large cable bundles or busbar assemblies in electrical power distribution systems rated up to 720 V AC. The transformer operates across a frequency range of 15 Hz to 400 Hz and connects to the evaluation unit via a two-wire interface cable up to 40 meters in length. Housed in a robust enclosure rated for continuous operation, the module provides primary insulation and current measurement capabilities for grounded and ungrounded AC electrical systems.
Key Technical Specifications
| Parameter | Specification |
| Manufacturer | Bender GmbH & Co. KG |
| Model / Type Code | W4-S140 |
| Part Number | B911734 |
| Device Type | Measuring current transformer / residual current transformer |
| Inner Diameter (Pass-through) | 140 mm |
| Highest System Voltage (Um) | AC 720 V |
| Frequency Range | 15 Hz to 400 Hz |
| Secondary Connection | 2-wire connection |
| Maximum Connection Length | Up to 40 m (depending on cable type) |
| Weight | Approximately 1500 g |
Detailed Product Overview
The Bender W4-S140 measuring current transformer functions as the primary sensing element in residual current monitoring and insulation fault location systems. In electrical installations, vector summation of all live conductors passing through the toroidal core results in zero net magnetic flux during normal operation. When an insulation fault occurs, the imbalance creates a proportional secondary current signal that the transformer delivers to connected Bender monitoring devices.
With its 140 mm internal opening, the W4-S140 is designed for main distribution boards, motor control centers (MCCs), and heavy industrial supply lines where multiple thick conductors or busbars must be routed through a single measuring point. The unit features built-in mounting feet for secure fastening inside switchgear cabinets and enclosure assemblies.
The transformer operates in combination with Bender RCM series residual current monitors and EDS series insulation fault locators. By transferring precise low-level current signals across a two-wire connection line, it enables early fault detection without triggering unnecessary system shutdowns.
Engineering Selection Highlights
- 140 mm Internal Diameter: Accommodates large multi-conductor cables and busbars in high-capacity electrical distribution circuits.
- AC 720 V System Voltage Rating: Suitable for standard low-voltage power distribution networks up to 720 V AC.
- 15 Hz to 400 Hz Frequency Range: Measures residual currents across standard line frequencies as well as variable-frequency system harmonics.
- 2-Wire Evaluator Interface: Simplifies field connection to Bender RCM and EDS evaluation devices over distances up to 40 meters.

W4-S140

W4-S140
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Evaluation Device | Bender RCM series residual current monitors & EDS series insulation fault locators | Connects via two-wire measurement signal cable up to 40 m. |
| Primary System Voltage | Up to AC 720 V rated insulation voltage | Suitable for low-voltage AC power distribution networks. |
| Conductor Pass-through | All active phase conductors and neutral conductor | Protective earth (PE) conductors must NOT be passed through the transformer core. |
| Signal Wiring | 2-wire connection lead | Ensure proper cable routing and twisted-pair cabling over longer distances to minimize noise interference. |
Dimensions, Mounting & Connection Notes
- Physical Dimensions: Features a 140 mm internal aperture diameter with an overall housing width of 197 mm and total height of 220 mm; unit weight is approximately 1500 g.
- Mounting Method: Screw-mounting via integrated base mounting slots directly onto cabinet backplanes or mounting plates.
- Conductor Routing Rules: All current-carrying conductors (L1, L2, L3, N) must pass through the center of the transformer in the same direction. Shielded cables and PE conductors must not pass through the aperture.
- Terminal Connection: Two screw-type secondary terminals for connection to the evaluation device line.
FAQ
What is the Bender W4-S140?
The Bender W4-S140 (Part Number: B911734) is a measuring current transformer with a 140 mm inner diameter used with Bender residual current monitors (RCM) and insulation fault location systems (EDS).
What size conductor bundle fits through the W4-S140?
The transformer has a 140 mm (approx. 5.5 inch) internal aperture, making it suitable for large cable bundles and industrial busbar runs.
Which conductors must pass through the transformer core?
All live conductors (phases and neutral, if present) must pass through the measuring aperture. The protective earth (PE) conductor must never be routed through the transformer.
What is the maximum system voltage rating for the W4-S140?
The W4-S140 is rated for electrical systems with a maximum system voltage (Um) of AC 720 V.
How far can the W4-S140 be installed from the evaluation device?
Depending on the cable cross-section and type used, the two-wire connection line between the transformer and the Bender evaluator can extend up to 40 meters.
Verification & Troubleshooting Notes
- Check Conductor Routing: Ensure that all active phase conductors and the neutral conductor pass through the transformer aperture, while PE conductors remain entirely outside.
- Verify Secondary Wiring Integrity: Check continuity and connection tightness on the two-wire secondary circuit leading to the evaluation device.
- Inspect Physical Alignment: Confirm that primary conductors are centered within the 140 mm opening as much as possible to avoid localized magnetic saturation.
- Shield Grounding Check: Ensure that cable shielding on primary power lines is grounded properly before the transformer and is not routed through the measuring aperture.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626