Description
3. Key Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Bently Nevada |
| Part Number | 135813-01 |
| Product Series | 3500 Machinery Protection System |
| Catalog Number | 3500/93 |
| Product Type | Display Interface I/O Module |
| Main Function | System display communication interface |
| Compatible Display | 3500/93 System Display |
| Rack Interface | 3500 backplane |
| Communication Interface | Display interface communication |
| Mounting Options | Face mount, panel mount, rack mount, independent mount |
| Display Data | System events, alarm lists, channel and module information |
| Operating Temperature | Approx. −30 °C to +65 °C |
| Weight | Approx. 0.4–1 kg depending on packaging/configuration |
| Application Standard | API 670 machinery protection systems |
The 135813-01 is referenced as the 3500/93 Display Interface I/O Module in Bently Nevada 3500 documentation. The 3500/93 display system provides access to rack information including event lists, alarms, and monitoring data.
4. Product Introduction
The Bently Nevada 135813-01 is a 3500/93 Display Interface I/O Module designed for the Bently Nevada 3500 Machinery Protection System. It provides the interface between the 3500 rack and the system display, allowing operators to view protection system status, alarms, events, and module information.
The module is used in industrial applications where local or remote visualization of rotating equipment protection data is required. Installation depends on the existing 3500 rack arrangement, display type, cable configuration, and mounting method.
- 135813-01
5. Installation & Configuration Guide
Stage 1: Pre-Installation Preparation (Approx. 10 minutes)
⚠️ Safety First
- Notify operations before maintenance activity.
- Confirm the machinery monitoring system is in an approved maintenance state.
- Isolate 3500 rack power according to site procedures.
- Wait for stored energy discharge before handling the module.
Tools Required
- ESD wrist strap
- Digital multimeter
- Screwdriver set
- Wire labels
- Smartphone/camera
Data Backup
- Record:
- 3500 rack slot location
- Existing module part number
- Display cable routing
- Current display configuration
- Photograph:
- Front module label
- Rack layout
- Cable connections
Stage 2: Removing the Old Module (Approx. 10 minutes)
- Open the 3500 rack access panel.
- Confirm installed module identification.
- Disconnect display interface cables carefully.
- Release module locking mechanism.
- Pull the module straight out.
⚠️ Important
Keep the original module until the replacement has been tested successfully.
Inspect:
- Backplane connector pins
- Rack slot condition
- Cable connectors
- Signs of overheating
Stage 3: Installing the New Module (Approx. 10 minutes)
- Wear ESD protection.
- Verify:
Existing: 135813-01
Replacement: 135813-01
- Confirm compatibility with the installed 3500/93 display system.
- Insert the module into the correct rack position.
- Secure the locking mechanism.
- Reconnect display cables.
Self-Checklist
- Correct part number confirmed
- Rack slot verified
- Cable connections secured
- Module locked in place
Stage 4: Power-On & Testing (Approx. 15–30 minutes)
Pre-Power Check
- Verify rack power supply.
- Check display cable connections.
- Confirm module seating.
Power-On Steps
- Restore 3500 rack power.
- Check module status.
- Confirm display communication.
- Verify:
- System event list
- Alarm event list
- Channel information
- Monitor module data
⚠️ Troubleshooting Note
If the display does not communicate:
- Check display cable type and length.
- Verify correct 3500/93 configuration.
- Confirm module seating.
- Check rack slot assignment.
6. Frequently Asked Questions (FAQ)
Q1: What is the Bently Nevada 135813-01 used for?
The 135813-01 is a 3500/93 Display Interface I/O Module used to connect the 3500 Machinery Protection System with its display interface for monitoring system status, alarms, and events.
Q2: Is the 135813-01 a vibration input module?
No. It does not directly measure vibration. It provides display interface functions for data already processed by 3500 monitoring modules.
Q3: Can the 135813-01 replace other 3500 display modules?
Not automatically. The 3500/93 system includes multiple display-related components. Verify the exact part number, rack configuration, and display hardware before replacement.
Q4: Can this module be hot-swapped?
Do not assume hot-swap operation. Follow the approved Bently Nevada 3500 maintenance procedure and site shutdown requirements.
Q5: What information can the 3500/93 display system show?
The system display can show:
- System event lists
- Alarm event lists
- Channel data
- Monitor module information
- Relay and Keyphasor-related information
Q6: Is Bently Nevada 135813-01 obsolete?
The 3500 platform is a mature industrial monitoring system. The 135813-01 remains available through surplus, unused, and refurbished industrial spare-part channels, depending on inventory.
Q7: What should be checked before purchasing?
Verify:
- Exact part number: 135813-01
- 3500 rack compatibility
- Display type
- Cable requirements
- Condition: New Original / Refurbished tested
For critical machinery protection systems, request inspection records and functional test information before installation.




WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626