Sale!

B&R X20PS9500 X20 Power Supply Module

The B&R X20PS9500 is a 24 VDC power supply module for X20 Compact or Fieldbus CPUs. It supplies power to the CPU, the X2X Link network, and the internal I/O, while providing electrical isolation between the primary supply and the CPU/X2X Link power supply. Parallel and redundant operation of the CPU/X2X Link supply is supported by connecting multiple modules.

Categories: , , , , SKU: X20PS9500 Brand:

Description

Core Product Summary

The B&R X20PS9500 is a 24 VDC power supply module for X20 Compact or Fieldbus CPUs. It supplies power to the CPU, the X2X Link network, and the internal I/O, while providing electrical isolation between the primary supply and the CPU/X2X Link power supply. Parallel and redundant operation of the CPU/X2X Link supply is supported by connecting multiple modules.

The module includes one RS232 interface (max. 115.2 kbit/s) and one CAN bus interface (max. 1 Mbit/s), both connected via a 12-pin terminal block. Nominal output power for the CPU/X2X Link supply is 7 W. Status indicators cover overload, operating state, module status, RS232, and CAN bus activity. It is used together with a compatible Compact or Fieldbus CPU base.

 

Key Technical Specifications

Parameter Value
Product type X20 power supply module
Primary function Supply for Compact or Fieldbus CPU, X2X Link, and internal I/O
Interfaces 1× RS232, 1× CAN bus
Input voltage (CPU/X2X Link) 24 VDC −15 % / +20 %
Input current (CPU/X2X Link) Max. 0.7 A
Fuse (CPU/X2X Link input) Integrated, non-replaceable
Reverse polarity protection (CPU/X2X Link) Yes
Nominal output power (CPU/X2X Link) 7 W
Parallel / redundant operation Yes
Overload characteristics Short-circuit proof, temporary overload
Input voltage (I/O supply) 24 VDC −15 % / +20 %
I/O supply fuse Required external line fuse: max. 10 A slow-blow
Nominal output voltage (I/O) 24 VDC
Permissible contact load (I/O) 10 A
Power consumption (internal I/O) 0.6 W
Power consumption for X2X Link supply 1.42 W
RS232 transfer rate Max. 115.2 kbit/s
CAN bus transfer rate Max. 1 Mbit/s
Electrical isolation CPU/X2X Link supply isolated from CPU/X2X Link power supply; I/O supply not isolated from I/O power supply
Degree of protection IP20
Operating temperature (horizontal) −25 to +60 °C
Operating temperature (vertical) −25 to +50 °C
Storage/transport temperature −40 to +85 °C
Relative humidity (operation) 5 to 95 %, non-condensing
Pitch 12.5 +0.2 mm
B&R ID code 0x2018

 

Detailed Product Overview

The X20PS9500 provides the primary 24 VDC power feed for X20 Compact CPUs and Fieldbus CPUs. It delivers power to the CPU itself, the X2X Link backplane network, and the internal I/O supply of connected modules. Electrical isolation is maintained between the incoming supply and the CPU/X2X Link power domain, while the I/O supply path is not isolated from the I/O power distribution.

The CPU/X2X Link output is rated at a nominal 7 W and supports both parallel connection and redundant operation when multiple supply modules are used simultaneously. The input side includes reverse-polarity protection and an integrated non-replaceable fuse; maximum input current is 0.7 A. The I/O supply path requires an external slow-blow fuse rated at a maximum of 10 A and can deliver up to 10 A contact load.

Two serial interfaces are integrated: an RS232 port (up to 115.2 kbit/s) that can be configured as an online interface, and a CAN bus interface (up to 1 Mbit/s). Both interfaces are wired through the same 12-pin terminal block used for power connections. Status LEDs indicate overload, operating state, module status, and activity on the RS232 and CAN bus channels. Diagnostics for module run/error and overload are available via LED and software.

The module is designed to mount on a compatible Compact CPU base (X20BB22 or X20BB27) or Fieldbus CPU base (X20BB3x/4x series). A 12-pin X20TB12 terminal block must be ordered separately. The unit carries IP20 protection and operates across the standard X20 temperature ranges for horizontal and vertical mounting.

X20PS9500

X20PS9500

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
System family B&R X20 Compact or Fieldbus CPU systems Used with Compact or Fieldbus CPU
CPU base X20BB22, X20BB27 (Compact) or X20BB3x/4x series (Fieldbus) Ordered separately
Terminal block X20TB12 (12-pin, 24 VDC keyed) Ordered separately
Power domains CPU/X2X Link supply and I/O supply Isolation only on CPU/X2X Link path
Redundancy CPU/X2X Link supply Supported by parallel operation of multiple modules
Interfaces and CAN bus Wired via the same terminal block

 

Dimensions, Mounting & Connection Notes

  • Pitch: 12.5 +0.2 mm
  • Mounting: On Compact or Fieldbus CPU base (DIN-rail system); horizontal or vertical orientation supported
  • Required accessories (ordered separately):
    – Terminal block: X20TB12
    – Compatible CPU base (X20BB22, X20BB27, or X20BB3x/4x series)
  • Degree of protection: IP20
  • Installation elevation: no limitation up to 2000 m; derate ambient temperature by 0.5 °C per 100 m above 2000 m
  • Connection: Power and interfaces via 12-pin terminal block

 

FAQ

What is the B&R X20PS9500?
It is a 24 VDC power supply module that feeds Compact or Fieldbus CPUs, the X2X Link network, and internal I/O power within the X20 system.

What power does the CPU/X2X Link output provide?
Nominal output power is 7 W. The output is short-circuit proof and supports temporary overload, parallel connection, and redundant operation.

Which interfaces are included?
One RS232 interface (max. 115.2 kbit/s) and one CAN bus interface (max. 1 Mbit/s), both connected via the 12-pin terminal block.

Is electrical isolation provided?
Yes, between the incoming supply and the CPU/X2X Link power supply. The I/O supply path is not isolated from the I/O power distribution.

What accessories are required?
A 12-pin X20TB12 terminal block and a compatible Compact or Fieldbus CPU base must be ordered separately.

What are the operating temperature limits?
Horizontal mounting: −25 to +60 °C. Vertical mounting: −25 to +50 °C.

Can multiple modules be used for redundancy?
Yes. Redundancy of the CPU/X2X Link supply is possible by operating multiple supply modules simultaneously.