Emerson Epro PR6424/006-030+CON021 Eddy Current Proximity Sensor Assembly

Parameter Specification
Manufacturer & Series Emerson / Epro, PR6424 Series
System Assembly Part Number PR6424/006-030 + CON021
Probe Model PR6424/006-030 (16mm tip diameter, /006 sleeve configuration)
Signal Converter Model CON021
Integral Cable Length 3.0 meters (-030 configuration)
Measuring Range 4.0 mm (160 mils) nominal linear range
Scale Factor / Sensitivity 4.0 V/mm (101.6 mV/mil) ± 5%
Frequency Response (-3 dB) 0 Hz to 20,000 Hz
Supply Voltage Range -23 V DC to -32 V DC (Nominal -24 V DC)
Categories: , , , , SKU: PR6424/006-030+CON021 Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The Emerson Epro PR6424/006-030+CON021 is a non-contact eddy current displacement measurement assembly designed for heavy-duty industrial turbomachinery protection and condition monitoring. This system pairs the PR6424/006-030 large-range proximity probe—featuring a 16mm tip diameter and a 3.0-meter integral high-frequency cable—with the matched CON021 signal converter to deliver continuous monitoring of axial shaft displacement, rod drop, thermal expansion, and relative shaft vibration.

Operating on the non-contact eddy current principle, the assembly measures static and dynamic distance changes between the 16mm ceramic/PEEK probe head and a conductive metallic target surface without physical wear. Due to its larger tip geometry, the PR6424 series provides an extended measuring range of up to 4.0 mm (160 mils), an output scale factor of 4.0 V/mm, and robust operation in severe thermal environments up to +200 °C for steam turbines, gas turbines, heavy turbo-compressors, and large reciprocating pumps.

 

Key Technical Specifications

Parameter Specification
Manufacturer & Series Emerson / Epro, PR6424 Series
System Assembly Part Number PR6424/006-030 + CON021
Probe Model PR6424/006-030 (16mm tip diameter, /006 sleeve configuration)
Signal Converter Model CON021
Integral Cable Length 3.0 meters (-030 configuration)
Measuring Range 4.0 mm (160 mils) nominal linear range
Scale Factor / Sensitivity 4.0 V/mm (101.6 mV/mil) ± 5%
Frequency Response (-3 dB) 0 Hz to 20,000 Hz
Supply Voltage Range -23 V DC to -32 V DC (Nominal -24 V DC)
Output Signal Range -2 V DC to -18 V DC proportional to gap distance
Probe Tip Operating Temperature -35 °C to +200 °C (-31 °F to +392 °F)
Converter Operating Temperature -30 °C to +100 °C (-22 °F to +212 °F)
Enclosure Protection Class Probe: IP66 / IP68; Converter (CON021): IP20

 

Detailed Product Overview

The Emerson Epro PR6424/006-030+CON021 transducer system supplies continuous condition monitoring systems and Distributed Control Systems (DCS) with real-time positional data on critical machinery rotors. The larger 16mm probe head is specifically selected for applications requiring an extended measurement range—such as axial thrust position monitoring, rod drop measurement on reciprocating compressors, and differential thermal expansion tracking on large steam turbine rotors.

The assembly relies on a matched circuit architecture: the CON021 signal converter supplies high-frequency excitation to the coil embedded inside the 16mm probe head via the 3.0-meter cable. Dynamic changes in the mechanical air gap modulate the electromagnetic field, which the CON021 translates into a proportional negative DC voltage output. The probe features hermetic sealing (IP66/IP68) and a heavy-duty threaded steel body to withstand hot lubricating oil, steam, and high housing pressures.

 

Engineering Selection Highlights

  • Extended 4.0 mm Linear Range: 16mm probe head geometry doubles the measuring range compared to standard 8mm probes, making it ideal for axial displacement and thermal expansion tracking.
  • 3.0-Meter Integral Cable Length: Provides sufficient cable reach to route through machine casings directly to external junction boxes without requiring intermediate connectors.
  • Matched Component Loop: Factory-calibrated pairing guarantees accurate 4.0 V/mm scale factor performance without requiring manual field tuning.
  • High Temperature Resilience: Rated for continuous operation up to +200 °C near hot bearings and turbine casings.
  • Non-Contact Wear-Free Operation: Tracks static shaft position (0 Hz) and dynamic position changes up to 20,000 Hz without physical contact.

 

Dimensions, Mounting & Connection Notes

  • Probe Tip Diameter: 16 mm outer diameter.
  • Integral Cable Length: 3.0 meters (approx. 9.8 ft) high-frequency coaxial cable.
  • CON021 Mounting: Compact aluminum housing secured via four M5 mounting screws inside a local junction box or cabinet rail.
  • Terminal Wiring: CON021 features screw terminal block connections supporting wire cross-sections up to 1.5 mm^2.
  • Mechanical Gap Setup: Set static mechanical gap using a feeler gauge or by monitoring the CON021 DC output voltage (typically set to mid-scale, approx. -10 V DC or 2.0 mm gap).
PR6424/006-030+CON021

PR6424/006-030+CON021

PR6424/006-030+CON021

PR6424/006-030+CON021

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Monitoring Racks & DCS Epro MMS6000 protection system, PLC analog inputs, or vibration monitors Channel input must support negative supply excitation (-24 V DC nominal) and negative voltage signal processing.
Target Material Standard Ferromagnetic steel targets (standard calibration on 42CrMo4 / AISI 4140) Target area diameter must be at least 30 mm to avoid edge-effect measurement errors.
Power Supply Requirement Regulated -24 V DC power supply Clean, low-ripple power input is required to prevent electrical supply noise on the output signal.
Cabinet Installation IP65/IP66 local junction box for CON021 mounting CON021 converter is rated IP20 and must be housed in a protective enclosure.

 

FAQ

What is the Emerson Epro PR6424/006-030+CON021?

It is a non-contact eddy current proximity transducer assembly consisting of a 16mm probe with a 3.0-meter integral cable (PR6424/006-030) and a signal converter (CON021).

How does the PR6424 series differ from the PR6423 series?

The PR6424 series uses a larger 16mm tip head providing a 4.0 mm linear range and 4.0 V/mm scale factor, whereas the PR6423 series uses an 8mm tip with a 2.0 mm range and 8.0 V/mm scale factor.

What power supply is required for the CON021 converter?

The CON021 converter requires a negative DC supply voltage ranging between -23 V DC and -32 V DC (nominally -24 V DC).

Can the CON021 converter be mounted directly on the machine?

No. The CON021 converter carries an IP20 protection rating and must be mounted inside a protective junction box or control cabinet near the machine.

What is the primary application for a 16mm probe system?

It is primarily used for axial thrust position monitoring, rod drop detection on compressors, and measuring large thermal expansion displacements on heavy turbomachinery.

 

Verification & Troubleshooting Notes

  • Initial DC Gap Voltage Check: Following mechanical installation, verify that the static DC output voltage at the CON021 terminal reads near the center of the linear working curve (typically -10 V DC for a 2.0 mm gap).
  • Target Area Clearance: Ensure the metal target surface diameter is at least 30 mm to prevent side clearance errors or uncalibrated magnetic field spreading.
  • Power Supply Integrity: Confirm that the power supply terminals receive a stable negative voltage (-24 V DC nominal) free from high-frequency switching noise.
  • Coaxial Connector Locking: Ensure the miniature coaxial connector between the probe cable and the CON021 converter is fully engaged and free of oil or moisture contamination.