Sale!

Emerson KJ4001X1-CG1 System Power Supply Carrier Base

  • Model: KJ4001X1-CG1 (VE4002S2T2B3)
  • Brand: Emerson DeltaV
  • Series: DeltaV M-Series / S-Series
  • Core Function: Houses and routes primary/secondary system power supplies to the DeltaV backplane.
  • Product Type: System Power Supply Carrier Assembly
  • Key Specs: Dual Power Supply Slots | Integrated 24 VDC Power Rail Distribution | Heavy-Duty DIN Rail Mount
  • Condition: New Original / New Surplus
  • Inventory Status: Critical backbone spare; keep 1 unit on-site as insurance against rack-wide power loss.
Categories: , , , , SKU: KJ4001X1-CG1 Brand:

Description

Key Technical Specifications

Parameter Specification / Value
Manufacturer Emerson Automation Solutions
Part Number KJ4001X1-CG1
Assembly Code VE4002S2T2B3
System Platform Emerson DeltaV DCS
Module Slots Dual Slots (for DeltaV System Power Supply Modules)
Input Voltage Range 24 VDC Nominal (Dual Redundant Input Terminals)
Backplane Current Rating 13 A total backplane power routing capacity
Bus Connections Integrated Left/Right Local Bus Extension Connectors
Operating Temperature −40°C to +70°C (−40°F to +158°F)
Storage Temperature −40°C to +85°C (−40°F to +185°F)
Relative Humidity 5% to 95% (non-condensing)
Mounting Format Standard 35 mm DIN Rail / Direct Panel Mount

 

Product Introduction & Supply Chain Strategy

The Emerson KJ4001X1-CG1 (VE4002S2T2B3) is a system power supply carrier engineered to mount and interconnect DeltaV power supply modules directly to the local node backplane. It serves as the primary power distribution hub across DeltaV controller and I/O carrier racks, feeding clean, isolated 24 VDC power and logic voltages across the backplane bus. Designed for redundant power architectures in process automation, this carrier ensures unbroken operation even if one power module or supply circuit experiences an electrical fault.

Securing this power carrier as New Surplus guarantees immediate delivery and full OEM-grade reliability without paying factory list prices or facing long manufacturer backorders. Unlike pulled or second-hand hardware, authentic New Surplus inventory ensures pristine gold connectors, uncracked housing clips, and uncompromised internal copper trace insulation. Holding a spare KJ4001X1-CG1 base in plant inventory shields your facility from total node shutdown risks caused by cabinet overvoltage surges or physical backplane terminal damage.

KJ4001X1-CG1

KJ4001X1-CG1

KJ4001X1-CG1

KJ4001X1-CG1

Installation & Configuration Guide

1.Pre-Installation (Prep & Safety):Prerequisite.

Isolate all incoming 24 VDC bulk feeder lines to the cabinet and execute Lock-Out/Tag-Out (LOTO). Attach a grounded ESD wrist strap to the enclosure frame. Photograph existing power bus connections and tag primary/secondary supply leads before removal.

2.Removal:Mechanical extraction.

Unlatch and remove installed power supply modules from the carrier. Disconnect local bus extension cables and unscrew incoming bulk power wires from the terminal headers. Unclamp the carrier release mechanism and slide the KJ4001X1-CG1 off the DIN rail.

3.Installation (Clone & Seat):Hardware mounting.

Inspect backplane contacts on the new KJ4001X1-CG1 for dust, oxidation, or bent pins. Securely mount the carrier onto the cabinet DIN rail until it latches tightly. Reattach the left/right local bus extension cables and reconnect primary and secondary 24 VDC bulk power leads to their respective terminals.

4.Power-On & Testing:System verification.

Re-insert power supply modules firmly into their slots until latches engage. Restore bulk 24 VDC power and confirm that power supply status LEDs glow solid green. Open DeltaV Diagnostics to verify that backplane power rails report normal operating voltage across all connected I/O carriers.

 

Firmware/Software Versions & Upgrade Notes

  • System Compatibility: Compatible with DeltaV v11.3.1 through v15.3 systems utilizing standard M-Series and S-Series power distribution layouts.
  • Hardware Hardware Pass-Through: The KJ4001X1-CG1 is a passive/active backplane power distribution assembly and does not host flash firmware. Hardware revision levels remain fully interchangeable and backward compatible across all DeltaV system power supply modules.
  • Power Capacity Limits: Ensure total current load drawn by controllers and I/O cards on the connected carrier chain does not exceed the maximum 13 A backplane power rating of the KJ4001X1-CG1 base.
  • Hot-Swapping Precaution: Power supply modules mounted on the carrier can be hot-swapped individually during active operation, but the KJ4001X1-CG1 base carrier itself must never be disconnected while powered.

 

Frequently Asked Questions (FAQ)

Q: Is this Emerson KJ4001X1-CG1 unit brand new or refurbished?

A: This product is a Brand New Surplus unit. It is not used, not pulled from a decommissioned plant, and not refurbished. All modules undergo rigorous quality verification to ensure OEM-level reliability.

Q: What makes New Surplus power carriers superior to refurbished alternatives?

A: Power supply carriers handle high continuous current loads. Refurbished or pulled carriers often suffer from thermal fatigue, oxidized copper bus connectors, and weakened DIN rail clips caused by long-term heat exposure. A failure on a second-hand power carrier can shut down an entire DCS node, costing tens of thousands of dollars per hour in unscheduled downtime.

Q: Does this power carrier support dual-redundant power supplies?

A: Yes, the KJ4001X1-CG1 features dual slots engineered to house two DeltaV system power supply modules side-by-side. It automatically routes dual power feeds so that if one supply or input rail fails, the system continues running without interruption.

Q: Why is New Surplus pricing lower than OEM list price?

A: New Surplus equipment comes from excess capital project allocations, system integrator stock overruns, or canceled facility expansion orders. You receive genuine, uninstalled OEM hardware at a 20% to 30% discount with immediate off-the-shelf delivery instead of standard factory lead times.

Q: Will swapping this power carrier require software reprogramming in DeltaV Explorer?

A: No, the KJ4001X1-CG1 is an electrical backplane infrastructure unit. System hardware configuration in DeltaV Explorer is assigned to controllers and I/O cards. Swapping this carrier base requires zero software changes or re-commissioning.

Q: What warranty coverage comes with this New Surplus assembly?

A: We supply this unit with a complete 1-year operational replacement warranty. Every carrier undergoes visual, mechanical, and backplane bus continuity verification before being sealed in ESD-protective packaging for dispatch.