Core Product Summary
The EPRO PR6424/010-110 + CON021 is a non-contact eddy-current measuring chain for rotating machinery monitoring. It consists of a PR6424 16 mm eddy-current sensor with a 10 mm measuring range and 5 m armored cable, together with a CON021 signal converter.
The system measures relative shaft displacement and dynamic vibration, and can also be applied to position, eccentricity and speed/key measurements. It is intended for critical turbomachinery such as steam, gas and hydro turbines, compressors, pumps and fans, where the conditioned voltage output is supplied to machinery monitoring or protection equipment.
Key Technical Specifications
| Item | Verified Information |
|---|---|
| Manufacturer / product family | EPRO / Emerson, PR6424 eddy-current sensor series |
| Exact configuration | PR6424/010-110 + CON021 |
| Sensor type | 16 mm non-contact eddy-current sensor |
| Probe measuring range | 10 mm |
| Cable option | 110-series cable, 5 m armored cable |
| Converter | CON021 signal converter |
| Sensitivity / linearity | 4 V/mm (101.6 mV/mil), linearity error ≤ ±1.5% |
| Nominal air gap | Approximately 2.7 mm |
| Static range | ±2.0 mm |
| Dynamic range | 0–1,000 µm |
| Target material | Ferromagnetic steel; 42 CrMo4 standard |
| Maximum target surface speed | 2,500 m/s |
| Minimum shaft diameter | 80 mm |
| Sensor operating temperature | -35 to +150 °C |
| Pressure resistance at sensor head | 10,000 hPa |
| Shock and vibration | 5 g at 60 Hz and +25 °C |
| Sensor weight | Approximately 200 g with 1 m cable, without armor |
| Converter output range | Factory setting -2 to -18 V; selectable -4 to -20 V |
| Converter frequency range | 0–20 kHz at -3 dB with 10 nF load |
| Converter rise time | Less than 15 µs with 1 nF load |
| Converter supply voltage | -23 to -32 V DC for -4 to -20 V output; -21 to -32 V DC for -2 to -18 V output |
| Converter protection / weight | IP20; 95 g |
Engineering Selection Highlights
- Complete measuring chain: The PR6424/010-110 and CON021 must be treated as a matched eddy-current measuring system; the converter conditions the probe signal and provides the voltage output used by monitoring or protection equipment.
- 10 mm probe range: The /010 designation identifies a 10 mm measuring-range probe, making this configuration suitable where the application requires that specific range and calibration.
- 5 m armored cable: The /110 designation identifies the 5 m armored-cable version, which should be selected where the installed cable length and mechanical protection requirements match.
- Shaft-displacement monitoring: The PR6424 measures relative radial and axial shaft displacement and dynamic vibration without contacting the shaft, supporting machinery condition monitoring and protection functions.
- Calibration dependency: The nominal 4 V/mm sensitivity, approximately 2.7 mm center air gap, and ferromagnetic-steel target requirement must match the monitoring system’s configured measuring range and calibration.
- Converter supply match: The CON021 requires a negative DC supply within its documented range; the selected output range determines the required supply window.
- Hazardous-area verification: The PR6424 sensor carries ATEX, IECEx and CSA documentation, but the applicable hazardous-area classification depends on the converter and installation; the approval label and converter documentation must be checked for the installed configuration.

PR6424 010-110+CON021

PR6424 010-110+CON021
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Sensor / converter pairing | PR6424/010-110 probe with CON021 converter | The CON021 completes the calibrated measuring chain and supplies the conditioned output signal. |
| Converter sensor compatibility | PR6422, PR6423, PR6424, PR6425 and PR6426 sensors | The CON021 is designed for EPRO PR642x eddy-current measuring chains. |
| Probe connection | Self-locking LEMO socket | The sensor connects to the converter through the converter’s LEMO socket. |
| Target material | Ferromagnetic steel; 42 CrMo4 standard | The measured shaft or target surface must be compatible with the eddy-current measurement principle and calibration. |
| Monitoring-system input | Voltage output from CON021 | The output range is factory-set to -2 to -18 V or selectable to -4 to -20 V, and must match the monitoring system input configuration. |
| Converter supply | Negative DC supply | Use -23 to -32 V DC for the -4 to -20 V output setting, or -21 to -32 V DC for the -2 to -18 V output setting. |
| Mounting | Sensor installed near the shaft; CON021 prepared for mounting-box installation | Maintain the documented nominal air gap and ensure secure mechanical mounting. |
| Hazardous-area installation | Converter and installation determine area classification | Check the converter documentation and approval label before use in a hazardous area. |
Dimensions, Mounting & Connection Notes
| Item | Verified Information |
|---|---|
| Sensor type | PR6424 16 mm eddy-current sensor |
| Probe measuring range | 10 mm |
| Cable | 5 m armored cable, 110-series designation |
| Sensor weight | Approximately 200 g with 1 m cable, without armor |
| Converter mounting | Prepared for installation in a mounting box |
| Converter protection | IP20 |
| Converter weight | 95 g |
| Converter operating temperature | -30 to +100 °C |
| Converter storage / transport temperature | -40 to +105 °C |
| Converter relative humidity | 0–95%, non-condensing |
The sensor must be mounted so that its face is positioned at the specified nominal air gap from the shaft or target surface. The CON021 is a panel-mount converter intended for installation in a mounting box, with the sensor connected through its self-locking LEMO socket. Cable shielding, grounding and separation from power wiring should follow the applicable installation requirements for the monitoring system.
Applications & System Role
The PR6424/010-110 + CON021 forms the front-end measuring chain of a machinery monitoring or protection system. The non-contact sensor observes shaft movement relative to its mounted position, while the CON021 converts the eddy-current sensor signal into a voltage proportional to displacement or vibration.
Typical measurement roles include radial shaft vibration, axial shaft displacement, shaft position, eccentricity and speed/key monitoring. In a turbomachinery protection architecture, the conditioned output can be supplied to a monitoring module or protection system for alarm evaluation, trip logic and machinery-condition analysis.
The system is intended for critical rotating equipment, including steam, gas and hydro turbines, compressors, pumps and fans. Its suitability depends on correct sensor mounting, target material, air-gap setting, cable integrity and matching converter output configuration.
Detailed Product Overview
The EPRO PR6424/010-110 + CON021 is a complete eddy-current measuring chain consisting of a PR6424 16 mm sensor and a CON021 signal converter. The PR6424/010-110 is a 10 mm-range probe fitted with a 5 m armored cable, while the CON021 provides signal conditioning and the voltage output required by machinery monitoring or protection equipment.
The PR6424 sensor operates without contacting the shaft. It measures relative displacement between the sensor tip and a ferromagnetic steel target, with a nominal sensitivity of 4 V/mm and a linearity error of no more than ±1.5%. The nominal center air gap is approximately 2.7 mm, the static range is ±2.0 mm, and the dynamic range is 0 to 1,000 µm. These values define the mechanical installation window and the measurement span that the monitoring system must be configured to interpret.
The CON021 converts the sensor signal into a voltage output. Its factory output range is -2 to -18 V, with a selectable -4 to -20 V range. The converter requires a negative DC supply: -23 to -32 V DC when configured for -4 to -20 V output, or -21 to -32 V DC when configured for -2 to -18 V output. Its frequency response extends to 20 kHz at -3 dB with a 10 nF load, and its rise time is less than 15 µs with a 1 nF load.
The PR6424 sensor is designed for demanding turbomachinery service. Its operating temperature range is -35 to +150 °C, its sensor head is pressure-resistant to 10,000 hPa, and it is rated for 5 g shock and vibration at 60 Hz and +25 °C. The sensor body uses a stainless-steel sleeve and PTFE cable insulation; the sensor and 1 m of cable weigh approximately 200 g before armored-cable additions.
For integration, the probe and converter should be treated as a calibrated pair. The target material, probe range, air gap, converter output range, monitoring-system input scaling and cable routing must all be consistent with the installed machinery-monitoring configuration. The PR6424 sensor documentation includes CE, ATEX, IECEx and CSA compliance information, but hazardous-area classification depends on the converter and installation, so the applicable approval documentation must be checked for the final installed configuration.
FAQ
What is the EPRO PR6424/010-110 + CON021?
It is a non-contact eddy-current measuring chain consisting of a PR6424 16 mm sensor with a 10 mm measuring range and 5 m armored cable, plus a CON021 signal converter.
What does the PR6424/010-110 measure?
It measures relative shaft displacement and dynamic vibration, and can also be used for position, eccentricity and speed/key measurements.
What does the CON021 do?
The CON021 conditions the PR6424 sensor signal and provides a voltage output for machinery monitoring or protection equipment.
What is the sensitivity of the PR6424?
The sensitivity is 4 V/mm (101.6 mV/mil), with a linearity error of no more than ±1.5%.
What is the measuring range of this configuration?
The probe has a 10 mm measuring range. The sensor’s static range is ±2.0 mm and its dynamic range is 0–1,000 µm.
What target material is required?
The sensor is specified for ferromagnetic steel targets, with 42 CrMo4 as the standard material.
What supply voltage does the CON021 require?
It requires -23 to -32 V DC for a -4 to -20 V output setting, or -21 to -32 V DC for a -2 to -18 V output setting.
What cable length does the /110 designation indicate?
The /110 designation identifies the 5 m armored-cable version of the PR6424/010 probe.
Where is this measuring chain used?
It is used in critical turbomachinery applications, including steam, gas and hydro turbines, compressors, pumps and fans, for shaft displacement, vibration, position, eccentricity and speed/key monitoring.

WhatsApp: +86 16626708626