The GE Multilin PQMII-T20 is a Power Quality Meter from the PQM II series designed for continuous monitoring of three-phase electrical systems. It measures voltage, current, power, energy, power factor, frequency, and harmonics while providing isolated analog outputs for integration with PLCs and SCADA systems.
The T20 option adds four isolated analog outputs (0–20 mA / 4–20 mA), one 4–20 mA analog input, and a second RS-485 communication port. The meter is commonly supplied in expanded configurations (such as PQMII-T20-C-A) that include additional control relays, switch inputs, harmonic analysis, waveform capture, and voltage disturbance recording.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Power Quality Meter |
| Series | Multilin PQM II |
| Configuration | T20 Transducer Option |
| Voltage Inputs | Three-phase (direct or via VT), typically up to 600 V range |
| Current Inputs | 1 A or 5 A secondary CT inputs |
| Frequency | 50/60 Hz nominal |
| Analog Outputs (T20) | 4 isolated (0–20 mA and 4–20 mA), assignable to measured parameters |
| Analog Input | 1 × 4–20 mA |
| Communication | Front RS-232 + dual rear RS-485 (with T20); Modbus RTU |
| Control Power | Standard 90–300 VDC / 70–265 VAC; low-range option available (20–60 VDC / 20–48 VAC) |
| Mounting | Panel mount |
| Common Full Option Code | PQMII-T20-C-A (adds control relays, switch inputs, and power analysis features) |
Detailed Product Overview
The PQMII-T20 provides comprehensive metering and power-quality analysis for industrial, commercial, and utility distribution systems. It continuously measures true-RMS voltage and current, calculates active, reactive, and apparent power, tracks energy consumption, and monitors power factor and frequency.
With the T20 transducer option, four isolated analog outputs can be assigned to any measured parameter, allowing the meter to replace multiple traditional transducers when interfacing to a PLC or DCS. A single 4–20 mA analog input accepts an external transducer signal (for example, temperature or level). The second RS-485 port supports simultaneous communication by different user groups.
When ordered with the Control (C) and Power Analysis (A) options, the meter gains four programmable output relays, four switch inputs, harmonic analysis, triggered waveform capture, event recording, data logging, and a voltage disturbance recorder for capturing sags and swells. These capabilities make the fully optioned unit suitable for both revenue-grade energy tracking and detailed power-quality diagnostics.
The PQM II platform is the recommended replacement for the earlier PQM, MPM, and MTM Plus meters, offering improved metering accuracy, expanded recording functions, and modern communication support while maintaining similar form factor and wiring practices.

PQMII-T20
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Voltage Sensing | Direct connection or VT inputs | Configurable VT ratios |
| Current Sensing | 1 A or 5 A secondary CTs | Standard CT connections |
| Analog Integration | 4 isolated analog outputs + 1 analog input (T20) | Direct PLC/SCADA interface |
| Communication | Modbus RTU via RS-485 / RS-232 | Second RS-485 port included with T20 |
| Control Functions | Available with C option (4 relays + 4 switch inputs) | For alarms and basic load control |
| Power Analysis | Available with A option | Harmonics, waveform capture, VDR |
| Control Power | Standard high-range or MOD 501 low-range | Match existing auxiliary supply |
| Software | EnerVista / PQM II setup software | For configuration and data retrieval |
Dimensions, Mounting & Connection Notes
The meter is designed for standard panel mounting. Rear terminals accept voltage, current, power, communication, and I/O wiring. Optional removable terminal blocks simplify installation and maintenance. Front-panel display and keypad provide local access to measured values and settings. Proper CT polarity, VT ratio configuration, and grounding must follow the instruction manual for accurate metering.
FAQ
What is the GE PQMII-T20?
It is a Multilin PQM II Power Quality Meter equipped with the T20 transducer option, providing four isolated analog outputs, one analog input, and a second RS-485 port.
What does the T20 option include?
Four isolated 0–20 mA / 4–20 mA analog outputs (assignable to measured parameters), one 4–20 mA analog input, and a second rear RS-485 communication port.
What measurements does it provide?
Voltage, current, power (W, var, VA), energy, power factor, frequency, demand, and (with analysis options) harmonics and voltage disturbances.
Is it suitable as a retrofit?
Yes. The PQM II is the recommended replacement for the discontinued PQM, MPM, and MTM Plus meters.
What communication protocols are supported?
Primarily Modbus RTU over RS-485 and RS-232. Additional protocols and Ethernet connectivity are available through accessories or expanded configurations.
What is the common fully optioned model?
PQMII-T20-C-A, which adds the Control option (relays and switch inputs) and the Power Analysis option (harmonics, waveform capture, event recording, and voltage disturbance recorder).