HIMA X-DO 32 01 HIMax Digital Output Module

The HIMA X-DO 32 01 (part no. 985210219) is a 32-channel digital output module for the HIMax programmable electronic system. Each of the 32 outputs carries a nominal current of up to 0.5 A at 24 VDC, and with high level the output presents a voltage equivalent to the module supply. The module is TÜV-certified for safety-related applications up to SIL 3 (IEC 61508, IEC 61511, IEC 62061), Category 4 (EN 954-1) and PL e (EN ISO 13849).

Categories: , , , , SKU: X-DO 32 01 Brand:

Description

Core Product Summary

The HIMA X-DO 32 01 (part no. 985210219) is a 32-channel digital output module for the HIMax programmable electronic system. Each of the 32 outputs carries a nominal current of up to 0.5 A at 24 VDC, and with high level the output presents a voltage equivalent to the module supply. The module is TÜV-certified for safety-related applications up to SIL 3 (IEC 61508, IEC 61511, IEC 62061), Category 4 (EN 954-1) and PL e (EN ISO 13849).

Each channel is built with three safety switches connected in series, making every output two-fault-tolerant with respect to its safety switch, and the de-energized state is the safe output state. Integrated, channel-by-channel short-circuit diagnosis and overload protection with automatic switch-off and cyclic retry support fault detection and maintenance. The module installs in any HIMax base plate slot except the slots reserved for system bus modules, and it requires a suitable X-CB 009 series connector board for field wiring, which is not included in the delivery scope.

 

Key Technical Specifications

Parameter Value
Product type Digital output module for the HIMax system
Part number 985210219
Number of outputs 32 digital outputs
Output voltage With high level: voltage equivalent to the supply voltage (24 VDC system)
Nominal output current Up to 0.5 A per channel
Load types Ohmic, inductive and capacitive loads
Channel isolation Outputs not electrically isolated from one another or from the supply voltage
Short-circuit diagnosis Integrated, channel-by-channel; line monitoring configured in SILworX, switching threshold predefined
Overload behavior Affected output switched off and switched on again after 5 s; repeats cyclically while overload persists
Safety switches 3 in series per channel; each individually switch-off capable via system bus (I/O bus) or second independent shutdown function; two-fault-tolerant per channel
Safe state De-energized output state
Module-internal architecture Safety-related 1oo2 processor system controlling and monitoring the I/O level; outputs read back and compared against expected values
Functional safety SIL 3 (IEC 61508 / IEC 61511 / IEC 62061), Cat. 4 (EN 954-1), PL e (EN ISO 13849)
System bus Redundant system buses A and B; module data exchanged with the processor modules
Indicators Module status (Run, Error, Stop, Init), system bus A/B, channel LEDs 1–32, Field
Operating temperature 0 °C to +60 °C
Storage temperature −40 °C to +85 °C
Humidity Max. 95 % relative humidity, non-condensing
Type of protection IP20
Pollution degree II
Installation altitude < 2,000 m
Dimensions (H × W × D) 310 × 29.2 × 230 mm

 

Detailed Product Overview

The X-DO 32 01 is the high-density digital actuation layer of a HIMax safety system: it converts the safe decisions of the HIMax processor modules into switched 24 VDC outputs that drive solenoid valves, contactors, relays and signaling devices. With 32 channels on a single module, it reduces module count and base plate slots for applications with large numbers of discrete final elements.

The channel architecture is engineered for functional safety rather than simple switching. Every output passes through three safety switches wired in series, so no single switch failure can energize an output that the logic has commanded off, and no two simultaneous switch failures are required to defeat the safety function — the channel is two-fault-tolerant with respect to the safety switches. Each switch can be shut down individually, either via the system bus (I/O bus) or via a second, independent shutdown path. The module’s internal safety-related 1oo2 processor system permanently monitors the I/O level: redundant processors compare the commanded values with the back-read actual values, and outputs that deviate from the expected state are reset. If a channel fault occurs, only that channel is set to its safe state; if a safety-relevant fault occurs, the module as a whole adopts the safe state, and a failure of the system bus also drives the outputs to the defined safe state, with the Error LED activated on the front plate.

Diagnostic depth is a practical selection argument. Short-circuits are detected per channel by integrated line monitoring, which must be enabled in the SILworX configuration; the detection threshold is predefined and not user-adjustable. The diagnostic information is reported across the redundant system bus, so the processor modules and the engineering station can localize a faulty channel without external measuring equipment. Overload protection works channel by channel: an overloaded output is switched off and retried after five seconds, and this cycle repeats as long as the overload persists — a behavior that supports locating wiring errors while limiting stress on the output stage. Where automatic retry is undesirable for the process, the user program must be configured to prevent the cyclic switch-on.

Two integration boundaries should be observed. First, the outputs are not electrically isolated from each other or from the module supply; circuits that require galvanic separation must be designed accordingly. Second, the module always operates as part of the HIMax architecture — it has no standalone mode. It communicates with the processor modules exclusively via the redundant system buses A and B, and full bus redundancy requires both system bus modules to be inserted and configured. Field connection is made exclusively through the connector board, which remains in the base plate when the module is exchanged, so rewiring is not required during module replacement.

Maintenance follows the HIMax scheme: the operating system can be updated during scheduled downtimes, and the module participates in the periodic proof testing required for the safety functions implemented with it. Defective modules are replaced with a faultless module of the same type or an approved replacement model; repair is reserved for the manufacturer.

X-DO 32 01

X-DO 32 01

X-DO 32 01

X-DO 32 01

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
System family HIMax programmable electronic system; communicates with the HIMax processor modules via system buses A and B No standalone operation; a HIMax system requires at least one X-CPU 01 processor module
Base plate slots Any base plate slot except the slots reserved for system bus modules Refer to the HIMax system manual for slot rules of the configured rack
System bus redundancy Redundancy only ensured if both system bus modules are inserted and configured Single bus operation is possible but does not provide bus redundancy
Connector board X-CB 009 01 (screw terminals), X-CB 009 02 (redundant screw terminals), X-CB 009 03 (cable plug) or X-CB 009 04 (redundant cable plug) — mandatory, not included in delivery Module and connector board form one functional unit; field wiring terminates on the connector board
Mechanical coding Coded connector boards from hardware revision AS10 onward; coded modules only plug into matching coded boards Prevents installation of improper I/O modules in redundant and field wiring
Field termination assembly Optional FTA connection via X-CA 006 system cable (8 m, 15 m or 30 m, single or redundant) FTA and system cable not included in the module delivery scope
Engineering software SILworX Required for hardware configuration, enabling short-circuit line monitoring and defining fault reactions
Supply 24 VDC via base plate (SELV/PELV) Operation in Ex zones only with additional measures
Replacement Faultless module of the same type or approved replacement model Only the manufacturer is authorized to repair the module

 

Dimensions, Mounting & Connection Notes

  • Dimensions (H × W × D): 310 × 29.2 × 230 mm; degree of protection IP20.
  • The module mounts in the HIMax base plate after the connector board has been inserted and secured in the corresponding slot (lower captive screw first, then upper). Hook the module into the hook-in rail, press the lower edge into place until it latches, and tighten the fixing screws.
  • Mounting and removal are possible while the HIMax system is operating. When the module is withdrawn, the connector board remains in the base plate with all field wiring attached, so module exchange requires no rewiring.
  • From hardware revision AS10, modules and connector boards carry mechanical coding (coding wedges); a coded module can only be plugged onto the correspondingly coded connector board. Uncoded connector boards accept any module.
  • Field connection is made on the connector board: screw-terminal versions or cable-plug versions (for FTA cabling) are available in standard and redundant variants. Outputs can be wired in 1-pole or 2-pole actuator configurations; redundant actuator wiring is supported for corresponding safety concepts.
  • For inductive loads, apply the wiring guidelines for load suppression defined in the module documentation to protect the outputs.
  • Outputs not in use are wired according to the documented wiring rules so that line monitoring behaves predictably and no false diagnostics are generated.
  • Environmental limits: 0 °C to +60 °C operating, −40 °C to +85 °C storage, max. 95 % relative humidity non-condensing, installation altitude below 2,000 m, pollution degree II. Observe ESD protective measures during all handling.

 

FAQ

What is the HIMA X-DO 32 01? It is a 32-channel digital output module for the HIMax programmable electronic system. Its 32 outputs each carry up to 0.5 A at 24 VDC and drive ohmic, inductive and capacitive loads such as solenoid valves and contactors.

Which safety integrity level does the module support? The module is TÜV-certified for safety-related applications up to SIL 3 per IEC 61508, IEC 61511 and IEC 62061, Category 4 per EN 954-1, and PL e per EN ISO 13849.

How is functional safety implemented on the outputs? Each channel contains three safety switches connected in series, making the output two-fault-tolerant with respect to the safety switches. The module’s internal 1oo2 processor system monitors commanded versus back-read output values, resets deviating outputs, and forces the module into its safe state on safety-relevant faults. The safe state is the de-energized state.

Does the module detect short-circuits? Yes. Short-circuits are diagnosed channel by channel. Line monitoring must be enabled in the SILworX configuration; the switching threshold is predefined and cannot be changed. An overloaded or shorted output is switched off and switched on again after five seconds, cyclically, until the cause is removed.

Which connector boards are required? The module needs one of the X-CB 009 series connector boards: screw-terminal (X-CB 009 01) or redundant screw-terminal (X-CB 009 02), cable-plug (X-CB 009 03) or redundant cable-plug (X-CB 009 04) versions. Connector boards are not included in the delivery scope.

In which slots can the module be installed? In any HIMax base plate slot except the slots reserved for system bus modules. Communication with the processor modules runs via the redundant system buses A and B.

Can the module be replaced during operation? Yes. It can be mounted and removed while the HIMax system is running; the connector board and field wiring remain in place. The replacement must be a faultless module of the same type or an approved replacement model.