Sale!

ICS Triplex T8402 60-Channel Dual Digital Input Module

The ICS Triplex T8402 is a Trusted Dual 24 Vdc Digital Input Module that interfaces to 60 field input devices. Fault tolerance is achieved through a One-Out-Of-Two D (1oo2D) voting architecture within the module for each of the 60 input channels.

Categories: , , , , SKU: T8402 Brand:

Description

Core Product Summary

The ICS Triplex T8402 is a Trusted Dual 24 Vdc Digital Input Module that interfaces to 60 field input devices. Fault tolerance is achieved through a One-Out-Of-Two D (1oo2D) voting architecture within the module for each of the 60 input channels.

Each field input is duplicated and the input voltages are measured using sigma-delta circuits. Line monitoring functions can be independently configured for each channel to detect open-circuit and short-circuit field wiring faults. The module provides on-board Sequence of Events (SOE) reporting with 1 ms resolution. It installs in a single-width I/O slot of a T8100 Controller Chassis or T8300 Expander Chassis and draws dual-redundant 20–32 V DC power from the backplane.

 

Key Technical Specifications

Parameter Value
Product type Trusted Dual 24 Vdc Digital Input Module
System family Trusted TMR / Trusted 8000 Series
Number of channels 60 dual (1oo2D) input channels
Architecture 1oo2D voting per channel within the module
Nominal field voltage 24 V DC
Backplane supply 20 V DC to 32 V DC
Power dissipation 20 W
Isolation 2500 V impulse withstand opto/galvanic barrier
Line monitoring Selectable per channel (open-circuit / short-circuit)
SOE resolution 1 ms
Module location T8100 or T8300 single-width I/O slot
Hot replacement Companion Slot or SmartSlot supported
Operating temperature 0 °C to +60 °C
Storage temperature –25 °C to +70 °C
Relative humidity 10 % to 95 %, non-condensing

 

Detailed Product Overview

The ICS Triplex T8402 provides high-density digital input acquisition for Trusted TMR safety systems. It accepts signals from 60 field devices such as switches, contacts or sensors and processes each channel through duplicated measurement paths. Voltage levels are measured by sigma-delta circuits on both paths; the results are voted using the internal 1oo2D architecture to produce a validated channel state.

Line monitoring is independently configurable on a per-channel basis. When enabled, the module can detect open-circuit and short-circuit conditions in the field wiring by comparing measured voltages against user-defined thresholds. Configurable digital filtering (50/60 Hz) helps reject field-induced noise.

On-board Sequence of Events (SOE) recording captures state changes with 1 ms resolution. A change of state on a configured channel generates a time-stamped SOE entry that is reported to the system SOE log. Comprehensive automatic diagnostics and self-test routines continuously monitor the health of the input circuits, measurement paths and internal circuitry.

The module occupies a single-width I/O slot and can be hot-replaced online using either a dedicated Companion (adjacent) Slot or a SmartSlot configuration. Front-panel status LEDs indicate overall module health, Active/Standby state and Educated status. Dual-redundant 24 V DC power is taken from the chassis Inter-Module Bus backplane; no field power is supplied by the module itself.

Field connections are made through a compatible Field Termination Assembly (typically from the T8800 series) and the associated multi-core cable. Threshold levels, filtering and line-monitoring options are configured via the Trusted System Configuration Manager and downloaded to the module.

T8402

T8402

T8402

T8402

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Chassis T8100 Controller Chassis or T8300 Expander Chassis Single-width I/O slot
System family Trusted TMR / Trusted 8000 Series Dual digital input module
Voting architecture Internal 1oo2D per channel Implemented within the single module
Field Termination Assembly Compatible T8800-series FTA (e.g. T8802) Required for field wiring
Cable Multi-core cable matched to FTA (e.g. TC-601 / TC-603 series) Connects FTA to module rear connector
Power Dual-redundant 20–32 V DC from chassis backplane Taken automatically from IMB
Hot replacement Companion Slot or SmartSlot Supported for online module change
Configuration tools Trusted System Configuration Manager Defines thresholds, filtering and line monitoring

 

Dimensions, Mounting & Connection Notes

  • Typical module dimensions: 241 mm (H) × 30 mm (W) × 300 mm (D)
  • Weight: approximately 1.13 kg
  • Mounting: Inserts into any single-width I/O slot of a T8100 or T8300 chassis; secured by ejector levers
  • Power connection: Taken from the chassis Inter-Module Bus backplane (dual redundant)
  • Field connection: Via rear connector to a compatible Field Termination Assembly and multi-core cable
  • Front panel: Status LEDs (Healthy, Active, Standby, Educated) and ejector levers

 

FAQ

What is the ICS Triplex T8402?
It is a Trusted Dual 24 Vdc Digital Input Module that interfaces to 60 field input devices using an internal 1oo2D voting architecture for each channel.

How many channels does the T8402 provide?
The module provides 60 dual (duplicated) input channels.

What voting method is used?
Each of the 60 channels uses a One-Out-Of-Two D (1oo2D) voting architecture implemented inside the module.

Does the module support line monitoring?
Yes. Line monitoring to detect open-circuit and short-circuit field wiring faults can be independently enabled and configured for each channel.

What is the Sequence of Events resolution?
The module provides on-board SOE reporting with 1 ms resolution.

Where can the T8402 be installed?
It occupies a single-width I/O slot in a T8100 Controller Chassis or T8300 Expander Chassis.

Can the module be replaced while the system is running?
Yes. Online hot replacement is supported using either a dedicated Companion Slot or a SmartSlot configuration.