Description
Core Product Summary (Brand / Model / Key Attributes)
The ICS Triplex T9110 is the core processor module for the Rockwell Automation AADvance safety and critical control platform. Operating within a T9100 processor base unit, this module executes application logic, manages system diagnostics, and controls real-time I/O data processing across distributed safety-instrumented loops. The AADvance architecture allows flexible controller scalabilities—operating as a single non-safety or SIL 1 processor, a dual-processor SIL 3 redundant system, or a triple-processor SIL 3 Triple Modular Redundant (TMR) fault-tolerant arrangement.
Engineered for demanding functional safety applications such as Emergency Shutdown (ESD), Fire and Gas (F&G) detection, and Burner Management Systems (BMS), the T9110 runs a TÜV-certified safety operating system. Powered by a 32-bit PowerPC processor running at 200 MHz with 128 MB RAM and 16 MB flash memory, the unit consumes just 8 W of power. The T9110 supports live hot-swapping and online updates, allowing seamless module replacement and logic maintenance without interrupting active process execution or opening safety loops.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer & Series | ICS Triplex / Rockwell Automation AADvance System |
| Model Number | T9110 |
| Module Type | AADvance Controller Processor Module |
| Processor Architecture | 32-bit PowerPC 405EP (200 MHz clock speed) |
| System Memory | 128 MB RAM, 16 MB Flash Memory |
| Safety Integrity Level | SIL 1 (1 CPU), SIL 3 (2 CPUs), SIL 3 TMR Fault Tolerant (3 CPUs) |
| Module Supply Power | 8 W (27.3 BTU/h) heat dissipation |
| System Operating Voltage | 18 VDC to 32 VDC (Nominal 24 VDC redundant input via base unit) |
| Configuration Software | AADvance Workbench (Version 1.x / 2.x) |
| Operating Temperature | -25 °C to 70 °C (-13 °F to 158 °F) |
| Relative Humidity | 10% to 95%, non-condensing |
| Hazardous Area Approvals | ATEX Zone 2 / IECEx / Class I, Division 2 certified |
Detailed Product Overview
The ICS Triplex T9110 Processor Module serves as the central processing engine for the Rockwell Automation AADvance process safety platform. Designed to bridge the gap between traditional rigid safety architectures and flexible industrial control needs, the T9110 allows safety system designers to scale hardware redundancy directly to match process risk profiles—ranging from simple SIL 1 functional loops up to full SIL 3 triple-voted TMR configurations.
At the physical and electrical level, T9110 processor modules plug directly into the T9100 Processor Base Unit. The base unit provides dual-redundant 24 VDC power feeds, dual-port Ethernet interface routing, serial communication connections, and passive backplane connectivity across to adjacent T9300 I/O base units. When configured in dual or triple arrangements, the T9110 modules perform hardware-assisted synchronization and cross-compared execution routines in real time, enabling continuous internal diagnostic coverage and automated fault isolation.
The module executes application programs created in the AADvance Workbench development environment, supporting IEC 61131-3 logic languages. The T9110 features onboard memory retention powered by an easily accessible backup battery, storing system state variables and event logs during power outages. Designed for extreme operational environments, the unit is rated for Class I, Division 2 and ATEX Zone 2 hazardous areas, making it suitable for unheated remote wellheads, offshore platforms, and petrochemical refining facilities.

T9110

T9110
Engineering Selection Highlights
- Scalable Redundancy Architecture: Software and base unit support 1, 2, or 3 T9110 modules to configure SIL 1, SIL 3 Dual, or SIL 3 TMR systems.
- Low Power Dissipation: Consumes only 8 W per processor module, minimizing cabinet thermal load and reducing cooling requirements.
- Online Hot-Swapping: Allows faulty processor modules to be extracted and replaced live without stopping application execution or disrupting field I/O.
- Integrated Hardware Diagnostics: Built-in self-testing continuously validates CPU health, memory integrity, and backplane communication paths.
- Hazardous Location Certified: Approved for deployment in ATEX Zone 2 and Class I, Division 2 hazardous operating environments.
- Automatic Module Configuration: Replacement modules automatically receive software configuration and network IP settings from the T9100 base unit upon insertion.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Processor Base Unit | T9100 Processor Base Unit | Mounts into designated processor slots (supports 1 to 3 T9110 modules). |
| I/O Base Unit | T9300 I/O Base Unit (3-way) | Connects via local backplane bus or T9310 expansion cables. |
| Expansion Cables | T9310 Expansion Cable Assembly | Used to extend the I/O bus across multiple DIN rail rows up to 8 meters total. |
| Engineering Workbench | AADvance Workbench (Version 1.x or 2.x) | Software programming and diagnostic toolset for system configuration. |
| Power Supply | Dual-Redundant 24 VDC Power Supply | Connects via 3-way PWR-1 and PWR-2 terminals on the T9100 base unit (18–32 VDC range). |
Dimensions, Mounting & Connection Notes
- Mounting Method: Plugs directly into the T9100 Processor Base Unit, which mounts onto standard TS35 DIN rail assemblies.
- Interfacing: External network connections (Dual Ethernet) and power supply terminations are located on the rear T9100 base unit rather than the removable T9110 module faceplate.
- Battery Maintenance: Contains a user-replaceable processor backup battery to preserve internal memory state during unpowered conditions.
- Bus Length Limit: Total combined I/O bus length (including base units and T9310 expansion cables) must not exceed 8 meters (26.2 feet).
- Thermal Management: Operating range of -25 °C to 70 °C (-13 °F to 158 °F); ensure proper cabinet spacing around base units to permit convection cooling.
FAQ
What is the primary function of the ICS Triplex T9110?
The ICS Triplex T9110 is the central processing module for the Rockwell AADvance controller, responsible for executing safety logic and managing system operations.
What base unit is required to house the T9110 module?
The T9110 module must be installed into a T9100 Processor Base Unit, which supports up to three T9110 processor modules.
How many T9110 processor modules are needed for a SIL 3 safety loop?
A SIL 3 safety system can be achieved using two T9110 processor modules for dual redundancy, or three T9110 modules for a SIL 3 TMR fault-tolerant system.
What programming software is used with the T9110 processor?
The T9110 processor is configured and programmed using Rockwell Automation’s AADvance Workbench software.
Can a faulty T9110 module be replaced while the system is running?
Yes, the T9110 supports hot-swapping. A replacement module inserted into the T9100 base unit automatically receives its IP address and configuration from the system without stopping the process.
What is the power consumption of a single T9110 module?
A single T9110 processor module has a power dissipation rating of 8 W (27.3 BTU/h).
Verification & Troubleshooting Notes
- Front Panel Indicators: Inspect the module LEDs (Power, Health, Active, Communications) to confirm operational status and identify processor fault conditions.
- Battery Replacement: If a low battery diagnostic alarm is generated, replace the internal processor backup battery according to manual procedures to avoid memory loss during power cycles.
- Module Seating: Ensure the locking mechanism on the T9110 module is fully engaged into the T9100 base unit to maintain reliable backplane contact.
- I/O Bus Verification: If downstream I/O base units fail to initialize, check that the total I/O bus cable length does not exceed the 8-meter limit and verify T9310 expansion cable seating.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626