Sale!

ICS Triplex TC-501 Trusted TMR I/O SmartSlot Cable

Parameter Specification
Manufacturer ICS Triplex
Product family Trusted 8000 Series
Model TC-501
Product type TMR I/O SmartSlot V2 cable
Cable function Internal input-to-FTA connection
Channel arrangement 40-channel input
Signal application Analog and digital inputs
Chassis connector 96-way Type C
Connector hood Single-width TC-500
Categories: , , , , SKU: TC-501 Brand:

Description

Core Product Summary

The ICS Triplex TC-501 is an internal SmartSlot V2 cable for connecting compatible 40-channel input modules to a Field Termination Assembly in a Trusted TMR control system. It supports analog and digital input signal connections and is designed for internal chassis-to-FTA installation.

The cable assembly uses a 96-way Type C connector in a single-width TC-500 hood at the chassis end and a 96-way Type R connector at the FTA end. Its documented module associations include T8403, T8423, T8425, and T8431, with corresponding termination assemblies selected according to the system configuration. The complete order code specifies the cable variant, insulation classification, and length.

 

Key Technical Specifications

Parameter Specification
Manufacturer ICS Triplex
Product family Trusted 8000 Series
Model TC-501
Product type TMR I/O SmartSlot V2 cable
Cable function Internal input-to-FTA connection
Channel arrangement 40-channel input
Signal application Analog and digital inputs
Chassis connector 96-way Type C
Connector hood Single-width TC-500
FTA connector 96-way Type R
Cable construction Multi-core cable
Cable protection Nylon Rilgain sheathing
Chassis-end preparation 1.5 m stripped-back section
FTA-end preparation 1.5 m stripped-back section
Grounding provision Sheathed braid for connector-hood safety earth
Screen termination Screen drain connected to a green wire at the remote end
Cable length Defined by the complete order code
Cable variants TC-501-02-xMx and TC-501-03-xMx

 

Detailed Product Overview

Internal SmartSlot Input Signal Connection

The TC-501 serves as an interconnection cable in the Trusted TMR I/O architecture. Its primary function is to transfer input signals from an internal Field Termination Assembly to a compatible input module installed in the Trusted chassis.

Unlike a general-purpose communication cable, the TC-501 uses dedicated multi-core wiring and specific connectors designed for the Trusted I/O hardware arrangement.

The cable supports input signal connections for both analog and digital input applications.

Supported Trusted Input Modules

The documented module associations include:

Input module Product designation
T8403 Trusted input module
T8423 Trusted input module
T8425 Trusted input module
T8431 Trusted input module

The corresponding FTA options include:

  • T8800
  • T8801
  • T8821
  • T8825
  • T8830/1

The correct combination must follow the Trusted I/O cable selection guide and the applicable module configuration.

Connector and Cable Construction

The TC-501 has two different connector interfaces:

  • Chassis end: A 96-way Type C connector installed in a single-width TC-500 hood.
  • FTA end: A 96-way Type R connector housed in a single-width hood.

The multi-core cable has a 1.5 m stripped-back section at both ends and is protected by nylon Rilgain sheathing. This construction provides a defined cable arrangement for internal cabinet installation.

Grounding and Shielding

Grounding provisions are incorporated into the cable assembly.

At both ends, a sheathed braid allows the connector hood to be connected to safety earth. At the FTA end, the multi-core screen drain is connected to a green wire for screen-earth termination.

These provisions should be maintained during installation and replacement. Incorrect screen or grounding connections can affect the electrical integrity of the I/O installation.

TC-501

TC-501

TC-501

TC-501

System Compatibility & Integration Requirements

Component Documented association
Control system ICS Triplex Trusted 8000 Series
Input modules T8403, T8423, T8425, T8431
Field Termination Assemblies T8800, T8801, T8821, T8825, T8830/1
Chassis interface 96-way Type C
FTA interface 96-way Type R
Connection arrangement Internal SmartSlot V2
Signal direction Input signals from FTA to input module

Important integration considerations

  1. Match the cable to the installed Trusted input module and FTA.
  2. Confirm both connector types before installation.
  3. Check the complete cable order code, including insulation and length suffixes.
  4. Maintain the designated safety-earth and screen-earth connections.
  5. Follow the applicable Trusted system installation instructions when disconnecting or reconnecting the assembly.

The TC-501 should not be confused with TC-502, which uses a flying-lead termination rather than an FTA connector.

 

Dimensions, Mounting & Connection Notes

The TC-501 is designed for internal cabinet routing between the Trusted chassis and its associated FTA.

Installation considerations include:

  • Check the available cable routing space before selecting the cable length.
  • Avoid excessive bending, pulling, or mechanical stress on the multi-core cable.
  • Protect connector contacts from contamination and physical damage.
  • Ensure both connector hoods are properly secured.
  • Maintain the designated grounding and screen connections.
  • Keep the cable away from sources of excessive electrical interference where practical.

The documented stripped-back cable section is 1.5 m at each end.

The cable ordering format includes a length designation. For example, TC-501-02-4M5 indicates a 4.5 m cable variant.

 

Frequently Asked Questions

Q1: What is the ICS Triplex TC-501?

The TC-501 is a Trusted TMR I/O SmartSlot V2 internal cable used to connect compatible 40-channel analog or digital input modules to a Field Termination Assembly.

Q2: Which Trusted modules use the TC-501?

The documented module associations include T8403, T8423, T8425, and T8431.

Q3: Which FTAs are associated with the TC-501?

The documented FTA associations include T8800, T8801, T8821, T8825, and T8830/1.

Q4: What connectors does the TC-501 use?

It uses a 96-way Type C connector at the chassis end and a 96-way Type R connector at the FTA end.

Q5: Is the TC-501 suitable for digital and analog input signals?

Yes. It is designed for input signal connections involving compatible Trusted analog or digital input modules.

Q6: What is the difference between TC-501 and TC-502?

The TC-501 connects the Trusted chassis to an FTA using a Type R connector. The TC-502 uses flying leads at the field termination end.

Q7: What should be checked before replacing a TC-501?

Check the full part number, cable length, insulation variant, chassis connector, FTA connector, and compatibility with the installed input module and termination assembly.