Description
Core Product Summary
The ICS Triplex TC-501 is an internal SmartSlot V2 cable for connecting compatible 40-channel input modules to a Field Termination Assembly in a Trusted TMR control system. It supports analog and digital input signal connections and is designed for internal chassis-to-FTA installation.
The cable assembly uses a 96-way Type C connector in a single-width TC-500 hood at the chassis end and a 96-way Type R connector at the FTA end. Its documented module associations include T8403, T8423, T8425, and T8431, with corresponding termination assemblies selected according to the system configuration. The complete order code specifies the cable variant, insulation classification, and length.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | ICS Triplex |
| Product family | Trusted 8000 Series |
| Model | TC-501 |
| Product type | TMR I/O SmartSlot V2 cable |
| Cable function | Internal input-to-FTA connection |
| Channel arrangement | 40-channel input |
| Signal application | Analog and digital inputs |
| Chassis connector | 96-way Type C |
| Connector hood | Single-width TC-500 |
| FTA connector | 96-way Type R |
| Cable construction | Multi-core cable |
| Cable protection | Nylon Rilgain sheathing |
| Chassis-end preparation | 1.5 m stripped-back section |
| FTA-end preparation | 1.5 m stripped-back section |
| Grounding provision | Sheathed braid for connector-hood safety earth |
| Screen termination | Screen drain connected to a green wire at the remote end |
| Cable length | Defined by the complete order code |
| Cable variants | TC-501-02-xMx and TC-501-03-xMx |
Detailed Product Overview
Internal SmartSlot Input Signal Connection
The TC-501 serves as an interconnection cable in the Trusted TMR I/O architecture. Its primary function is to transfer input signals from an internal Field Termination Assembly to a compatible input module installed in the Trusted chassis.
Unlike a general-purpose communication cable, the TC-501 uses dedicated multi-core wiring and specific connectors designed for the Trusted I/O hardware arrangement.
The cable supports input signal connections for both analog and digital input applications.
Supported Trusted Input Modules
The documented module associations include:
| Input module | Product designation |
|---|---|
| T8403 | Trusted input module |
| T8423 | Trusted input module |
| T8425 | Trusted input module |
| T8431 | Trusted input module |
The corresponding FTA options include:
- T8800
- T8801
- T8821
- T8825
- T8830/1
The correct combination must follow the Trusted I/O cable selection guide and the applicable module configuration.
Connector and Cable Construction
The TC-501 has two different connector interfaces:
- Chassis end: A 96-way Type C connector installed in a single-width TC-500 hood.
- FTA end: A 96-way Type R connector housed in a single-width hood.
The multi-core cable has a 1.5 m stripped-back section at both ends and is protected by nylon Rilgain sheathing. This construction provides a defined cable arrangement for internal cabinet installation.
Grounding and Shielding
Grounding provisions are incorporated into the cable assembly.
At both ends, a sheathed braid allows the connector hood to be connected to safety earth. At the FTA end, the multi-core screen drain is connected to a green wire for screen-earth termination.
These provisions should be maintained during installation and replacement. Incorrect screen or grounding connections can affect the electrical integrity of the I/O installation.

TC-501

TC-501
System Compatibility & Integration Requirements
| Component | Documented association |
|---|---|
| Control system | ICS Triplex Trusted 8000 Series |
| Input modules | T8403, T8423, T8425, T8431 |
| Field Termination Assemblies | T8800, T8801, T8821, T8825, T8830/1 |
| Chassis interface | 96-way Type C |
| FTA interface | 96-way Type R |
| Connection arrangement | Internal SmartSlot V2 |
| Signal direction | Input signals from FTA to input module |
Important integration considerations
- Match the cable to the installed Trusted input module and FTA.
- Confirm both connector types before installation.
- Check the complete cable order code, including insulation and length suffixes.
- Maintain the designated safety-earth and screen-earth connections.
- Follow the applicable Trusted system installation instructions when disconnecting or reconnecting the assembly.
The TC-501 should not be confused with TC-502, which uses a flying-lead termination rather than an FTA connector.
Dimensions, Mounting & Connection Notes
The TC-501 is designed for internal cabinet routing between the Trusted chassis and its associated FTA.
Installation considerations include:
- Check the available cable routing space before selecting the cable length.
- Avoid excessive bending, pulling, or mechanical stress on the multi-core cable.
- Protect connector contacts from contamination and physical damage.
- Ensure both connector hoods are properly secured.
- Maintain the designated grounding and screen connections.
- Keep the cable away from sources of excessive electrical interference where practical.
The documented stripped-back cable section is 1.5 m at each end.
The cable ordering format includes a length designation. For example, TC-501-02-4M5 indicates a 4.5 m cable variant.
Frequently Asked Questions
Q1: What is the ICS Triplex TC-501?
The TC-501 is a Trusted TMR I/O SmartSlot V2 internal cable used to connect compatible 40-channel analog or digital input modules to a Field Termination Assembly.
Q2: Which Trusted modules use the TC-501?
The documented module associations include T8403, T8423, T8425, and T8431.
Q3: Which FTAs are associated with the TC-501?
The documented FTA associations include T8800, T8801, T8821, T8825, and T8830/1.
Q4: What connectors does the TC-501 use?
It uses a 96-way Type C connector at the chassis end and a 96-way Type R connector at the FTA end.
Q5: Is the TC-501 suitable for digital and analog input signals?
Yes. It is designed for input signal connections involving compatible Trusted analog or digital input modules.
Q6: What is the difference between TC-501 and TC-502?
The TC-501 connects the Trusted chassis to an FTA using a Type R connector. The TC-502 uses flying leads at the field termination end.
Q7: What should be checked before replacing a TC-501?
Check the full part number, cable length, insulation variant, chassis connector, FTA connector, and compatibility with the installed input module and termination assembly.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626