Sale!

Kollmorgen SRB-MS-ILK5 24 VDC Safety Relay for Servo Drive Systems

Parameter Value
Product type Safety relay and interlock module (safety function module for servo drive systems)
Manufacturer Kollmorgen (Danaher Motion product line)
Model SRB-MS-ILK5
Product series KSM safety solution modules
Safety function Safe torque off (STO) — disables drive output and removes motor torque without removing power from the whole machine
Monitored circuits Dual-channel safety inputs including emergency-stop and safety gate (interlock) contacts
Supply voltage 24 VDC
Application scope Machine safety interlocks, emergency stop systems, motion control during fault conditions; industrial automation, robotics and CNC machine tools
System context Used with Danaher Motion / Kollmorgen servo drive systems
Categories: , , , , SKU: SRB-MS-ILK5 Brand:

Description

Core Product Summary

The Kollmorgen SRB-MS-ILK5 is a safety relay and interlock module from Kollmorgen’s KSM safety solution series, engineered for Danaher Motion / Kollmorgen servo drive systems. Its core function is safe torque off (STO): on a safety demand, it disables the servo drive’s output so the motor can no longer produce torque — removing motion from the machine axis without having to power down the entire machine or control system.

The module monitors dual-channel safety input signals such as emergency-stop buttons and safety gate (guard door) contacts, and activates the required protective action when a safety circuit opens or a fault is detected. It operates on a 24 VDC supply, which keeps the safety chain electrically separated from the machine’s drive power. In practice it sits between the machine’s safety devices and the servo system: robots, CNC machine tools and automated cells use it to guarantee that opening a guard or pressing an E-stop removes axis torque immediately, while the rest of the machine — controller, communications, non-safety I/O — stays powered and ready for a quick restart once the safety circuit is closed again.

 

Key Technical Specifications

Parameter Value
Product type Safety relay and interlock module (safety function module for servo drive systems)
Manufacturer Kollmorgen (Danaher Motion product line)
Model SRB-MS-ILK5
Product series KSM safety solution modules
Safety function Safe torque off (STO) — disables drive output and removes motor torque without removing power from the whole machine
Monitored circuits Dual-channel safety inputs including emergency-stop and safety gate (interlock) contacts
Supply voltage 24 VDC
Application scope Machine safety interlocks, emergency stop systems, motion control during fault conditions; industrial automation, robotics and CNC machine tools
System context Used with Danaher Motion / Kollmorgen servo drive systems

 

Engineering Selection Highlights

  • STO is faster to recover than a power-down. Because the module removes motor torque at the drive-output stage while the machine keeps its control power, the axis is ready to resume motion as soon as the safety circuit is closed — the engineering reason STO exists as an alternative to cutting the drive’s mains supply on every safety demand.
  • Dual-channel input monitoring fits standard safety architectures. The module is designed for dual-channel safety signals — the conventional wiring for E-stop buttons and guard-door interlocks — so it slots into the machine’s existing safety chain rather than requiring a redesigned safety concept.
  • 24 VDC supply separates the safety chain from drive power. The safety electronics run on the machine’s 24 V control voltage, keeping safety signal levels well away from servo power levels and allowing the safety circuit to be verified while the drive section is de-energized.
  • Selection is system-driven, not standalone. The module belongs to the Kollmorgen KSM safety solution family and works with Danaher Motion / Kollmorgen servo drive systems; the safety function is only valid when the module, drive and wiring are combined per the drive system’s safety documentation.
  • The application class tells you where it belongs. The module is used in industrial automation, robotics and CNC machine tools to monitor safety interlocks and control machine movement during fault conditions — any axis whose unexpected motion presents a hazard to personnel is a candidate.
  • Safety documentation governs the validation. Because this is a safety component, the loop — safety device, module, drive output stage — must be validated per the machine’s safety assessment; a functional test of the STO path is part of commissioning, not an optional check.
SRB-MS-ILK5

SRB-MS-ILK5

SRB-MS-ILK5

SRB-MS-ILK5

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Host drive system Danaher Motion / Kollmorgen servo drive systems The STO function acts on the servo drive’s output; confirm the drive’s safety documentation covers this module family
Product family Kollmorgen KSM safety solution modules Select within the KSM family per the drive system’s safety configuration
Safety inputs Dual-channel signals from emergency-stop devices and safety gate (interlock) contacts Standard dual-channel safety wiring; both channels must behave consistently for a valid safety demand
Supply voltage 24 VDC Wire from the machine’s safety-rated control voltage supply
Safety function behavior Disables drive output and removes motor torque on demand Drive power and machine control remain energized; verify restart behavior in the drive’s safety documentation
Application environment Control cabinet installation within industrial automation, robotics and CNC machine tools Follow the machine’s electrical design and the drive system’s installation documentation

 

Detailed Product Overview

Machine safety design always balances two goals that pull in opposite directions: people must be protected from unexpected motion, and production must not stop more often or longer than the risk actually requires. The safe torque off concept exists precisely on that balance point, and the SRB-MS-ILK5 is Kollmorgen’s safety relay and interlock module implementing it for Danaher Motion / Kollmorgen servo systems.

Consider what the alternative looks like. Without an STO path, the simple way to guarantee no motor torque is to remove the drive’s power supply — but then the machine loses its control state, position references can be disturbed, and restart means a power-up sequence. On a machine with frequent, legitimate operator access — a CNC machine tool with a guard door, a robot cell with a load station — that cost multiplies over every shift. STO removes the torque-producing capability of the drive output stage directly, through a dedicated safety path, while everything else stays alive. The result is a machine that is equally safe but faster to cycle.

The module’s input side is built for the safety architecture most machines already use. Emergency stops and safety gates are wired as dual-channel circuits; the module monitors these channels and expects them to change state together. A discrepancy — one channel open, one closed — is treated as a fault rather than a valid demand, which is the behavior that makes the safety chain resistant to a single wiring failure or a stuck contact. This dual-channel discipline is why the module integrates into existing safety chains rather than forcing a redesign.

Electrically, the module runs on 24 VDC — the control-level supply. This is a deliberate separation: safety signal wiring operates at control voltage, safely apart from the servo power section, and the safety function does not depend on the drive’s high-voltage input being switched. For the machine builder, that means safety wiring can follow ordinary low-voltage practices and be checked independently of drive commissioning.

Two engineering cautions frame the use of this component. First, it is a safety component, so it is not selected in isolation: the safety function is a property of the whole path — safety device, module, drive output stage, wiring — and it must be chosen and validated against the drive system’s safety documentation and the machine’s risk assessment. The module’s contribution is the monitoring and switching; the achieved safety level depends on the complete configuration. Second, the documented application class — monitoring safety interlocks and controlling machine movement during fault conditions in automation, robotics and CNC machine tools — is the correct scope for its use. It is not a general-purpose relay, and repurposing it outside the drive system it was designed for would take it outside its validated context.

For procurement, the SRB-MS-ILK5 is a like-for-like spare in machines that were built with the KSM safety solution family. The ordering reference is the full model string, and receiving inspection should confirm the module’s designation before installation in a safety circuit.

 

Applications & System Role

The SRB-MS-ILK5 sits in the safety chain between the machine’s safety devices and the servo drive’s output stage. Its role is to translate a safety demand — an opened guard door, a pressed emergency stop — into the immediate, controlled removal of motor torque from the machine’s servo axes, and to keep that state enforced until the safety circuit permits restart.

In a typical cell, the safety devices (E-stop buttons, safety gates, interlock switches) form a dual-channel circuit that the module continuously monitors. When the circuit opens, the module’s safety function disables the drive output: the motor can no longer generate torque, so an operator reaching into the guarded area is not exposed to unexpected axis motion. Because only torque is removed — not the machine’s control power — the controller retains its state, programs and communications, and the axis can return to operation quickly after the safety demand clears. This is the documented usage pattern in industrial automation, robotics and CNC machine tools: machines where safety interlocks must protect personnel without making every access a full shutdown-and-restart cycle.

 

FAQ

What is the Kollmorgen SRB-MS-ILK5?
It is a safety relay and interlock module from Kollmorgen’s KSM safety solution series, designed for Danaher Motion / Kollmorgen servo drive systems.

What does SRB-MS-ILK5 do?
It provides safe torque off (STO): when a safety demand occurs, it disables the servo drive’s output so the motor cannot produce torque, while the machine’s control system stays powered.

What safety inputs does it monitor?
Dual-channel safety input signals, such as emergency-stop buttons and safety gate (guard door) interlock contacts, activating the protective action when the circuit opens or a fault is detected.

What supply voltage does it need?
It operates on a 24 VDC supply, keeping the safety chain electrically separate from the machine’s servo drive power.

Where is this module typically used?
In industrial automation, robotics and CNC machine tools — machines that use safety interlocks to monitor access and must control axis motion during fault conditions.

Does pressing the E-stop shut down the whole machine?
No — with the STO function, the module removes motor torque without removing power from the whole machine, so the machine remains ready for a quick restart once the safety circuit is closed.

Is the SRB-MS-ILK5 a standalone safety device?
No — the safety function is valid only as part of the complete path of safety device, module and servo drive, configured and validated according to the drive system’s safety documentation and the machine’s safety assessment.