Description
Key Technical Specifications
| Parameter | Value |
|---|---|
| Model designation | NA1077 (TCI) |
| Manufacturer part number | 6200421 |
| Manufacturer | Kongsberg |
| Board revision | Revision B2 |
| Product type | Transceiver interface printed circuit board |
| System association | Kongsberg TCI transceiver interface architecture |
| Function | Interfaces transceiver signals with the associated Kongsberg control system |
| Mounting | PCB-mounted module for Kongsberg equipment enclosure |
| Typical application | Marine, subsea, acoustic, navigation, or control-system signal interfacing |
| Condition | New Original / New Surplus |
| Verification requirement | Match P/N 6200421 and Revision B2 before installation |
Public supplier listings identify the Kongsberg 6200421 as a Revision B2 transceiver interface PCB associated with the NA1077 (TCI) designation. Marketplace and distributor references consistently describe it as a Kongsberg TCI transceiver interface module rather than a general-purpose I/O card.
Product Introduction
The Kongsberg NA1077 (TCI), part number 6200421, is a transceiver interface printed circuit board used in Kongsberg TCI-related control and communication equipment. It provides the signal-interface function between transceiver circuitry and the surrounding Kongsberg system.
This listing covers the Revision B2 board. Because Kongsberg marine and subsea systems can use multiple NA-series interface boards with similar names, buyers should verify both the 6200421 part number and the board revision before ordering.

NA1077 TCI 6200421

NA1077 TCI 6200421
Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| No communication from transceiver | Transceiver power, cable, connector, or external transceiver fault | ❌ Low | Measure supply voltage and inspect cable/connector continuity at the transceiver | Verify external transceiver and cabling before replacing the interface PCB |
| Interface PCB not recognized | Incorrect board revision, poor connector seating, or system configuration mismatch | ✅ High | Confirm P/N 6200421 and Rev. B2; reseat connectors with system power off | Verify board revision and configuration before ordering a replacement |
| Intermittent signal loss | Loose connector, corroded contacts, damaged ribbon/cable, or EMI issue | ✅ High | Inspect and reseat connectors; check cable shielding and grounding | Clean/reseat connectors and inspect cabling before condemning the PCB |
| System reports transceiver fault | Transceiver failure, firmware/configuration mismatch, or interface-board fault | ✅ High | Swap the interface board with a known-good Rev. B2 unit if available | Replace the PCB only after external transceiver and configuration checks pass |
| Board shows heat damage or corrosion | Moisture ingress, overvoltage, or previous surge event | ✅ High | De-energize and visually inspect PCB, connectors, and surrounding enclosure | Replace immediately; investigate the moisture or overvoltage source |
| No LEDs or no system response | Rack power, fuse, backplane, or enclosure power fault | ❌ Low | Measure supply voltages at the equipment rack and inspect fuses | Check system power before replacing the interface board |
If the fault remains unresolved, send photos of both sides of the PCB, connector markings, system configuration, error logs, and the transceiver nameplate before ordering a replacement.
Frequently Asked Questions
What is the Kongsberg NA1077 (TCI) 6200421?
It is a Kongsberg transceiver interface PCB, commonly listed as Revision B2, used in TCI-related Kongsberg equipment. The 6200421 number is the manufacturer part number; NA1077 is the model/designation associated with the board.
Is the NA1077 TCI 6200421 obsolete?
Yes. It is a legacy Kongsberg interface board, and public listings identify it as a discontinued or limited-availability spare. Supply is generally limited to New Surplus, refurbished, or tested pre-owned inventory.
Can I use a different board revision instead of Rev. B2?
Do not assume compatibility. Kongsberg systems can be sensitive to PCB revision, firmware, connector pinout, and configuration differences. Match P/N 6200421 and Revision B2 unless Kongsberg technical support confirms that another revision is approved for your system.
Will this board work in any Kongsberg system?
No. It is intended for the specific Kongsberg TCI transceiver-interface application associated with part number 6200421. Verify the equipment model, serial number, system documentation, and installed board markings before installation.
Will configuration or calibration remain after replacement?
Not necessarily. Depending on the system architecture, configuration may reside in the host controller, transceiver, or another module. Back up system configuration and record all jumper/connector settings before removing the original PCB.
Why is this surplus board less expensive than a new OEM unit?
Because Kongsberg no longer supplies it as standard new production, pricing reflects available surplus inventory. New Surplus stock is unused original product; it may have older date codes but should not have field-operating hours.
What should I verify before ordering?
Confirm the exact part number 6200421, Revision B2 marking, system model, connector layout, firmware/configuration requirements, and whether your application requires a tested board with diagnostic documentation.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626