Description
Core Product Summary
The Kongsberg WCC 600 is a marine Watch Call panel for unmanned engine-room operation. It combines engine-room alarm indication with watch-transfer and engineer-call functions, and is used on the bridge, in duty engineers’ cabins, and in public crew areas.
The panel uses a 5.7-inch LCD touch display and communicates with the main computer in a Kongsberg K-Chief alarm system over a high-speed CAN network. It supports 13 alarm groups, a common machinery-alarm indication, system-failure indication, buzzer and sound-off controls, alarm summary presentation, and configuration for up to eight on-duty engineers.
Key Technical Specifications
| Item | Verified value |
|---|---|
| Manufacturer | Kongsberg Maritime |
| Product designation | WCC 600 |
| Product type | Watch Call panel |
| Application | Unmanned engine-room operation |
| Display | 5.7-inch LCD touch panel |
| Alarm groups | 13 |
| Common machinery alarm | 1 common alarm lamp and 1 repeat common machinery alarm |
| Engineers on duty | Facilitates 8 engineers on duty |
| Communication | High-speed CAN network to K-Chief alarm-system main computer |
| Supply voltage | 18 to 32 VDC |
| Power consumption | 5 W |
| Operating temperature | -15°C to +70°C |
| Ingress protection | IP44 |
| Environmental properties | IACS E10; IEC 60945 |
| Optional function | Fire alarm |
Detailed Product Overview
The WCC 600 is the operator-facing Watch Call unit in a Kongsberg K-Chief-based alarm and monitoring installation. Its primary role is to make engine-room alarm conditions visible and audible outside the engine room, while also managing the transfer of machine-watch responsibility between the bridge and the duty engineer.
On the bridge, the panel indicates engine-room alarms and supports acceptance of watch-transfer requests. In engineers’ cabins and public quarters, it indicates engine-room alarms while the machinery space is under bridge control and allows the on-duty engineer to be called.
When an alarm occurs, the WCC 600 gives both a buzzer signal and a visual indication. It automatically switches to the Alarm Summary page, where the operator can review the relevant alarm information; alarm grouping can be configured to the vessel’s specification.
The panel’s CAN connection to the K-Chief main computer allows a redundant arrangement with automatic changeover to another main computer if the primary computer fails. This makes the WCC 600 part of the vessel’s alarm and monitoring architecture rather than an isolated local display.
The unit is specified for 18 to 32 VDC supply, consumes 5 W, operates from -15°C to +70°C, and carries an IP44 ingress-protection rating. Its environmental properties include IACS E10 and IEC 60945.

WCC 600

WCC 600
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Automation system | Kongsberg K-Chief alarm system | The WCC 600 communicates with the K-Chief main computer. |
| Network | High-speed CAN | The panel uses CAN communication with the main computer. |
| Redundancy | Automatic changeover to another main computer | A redundant solution can be provided. |
| Power supply | 18 to 32 VDC | Provide a supply within the stated DC range. |
| Installation locations | Bridge, engineer on duty’s cabin, public quarters | The intended mounting locations are defined in the product description. |
| Alarm configuration | Customer-specific alarm grouping | Alarm grouping can be configured according to the customer’s specification. |
Dimensions, Mounting & Connection Notes
The WCC 600 is a panel-mounted Watch Call unit intended for the bridge, duty engineers’ cabins, and public quarters. It is equipped with a 5.7-inch LCD touch display for alarm presentation and navigation.
The manufacturer documentation specifies an 18 to 32 VDC supply, 5 W power consumption, IP44 ingress protection, and operation from -15°C to +70°C. Exact outline dimensions, cutout details, connector assignments, and wiring requirements should be taken from the WCC 600 outline drawing and Watch Call Panels document identified in the approval schedule.
FAQ
What is the Kongsberg WCC 600?
It is a marine Watch Call panel used for unmanned engine-room operation, alarm indication, and watch-transfer management.
Where is the WCC 600 installed?
It can be mounted on the bridge, in the duty engineer’s cabin, and in public quarters.
What display does the WCC 600 use?
It uses a 5.7-inch LCD touch panel.
How does the WCC 600 communicate with the vessel system?
It communicates with the K-Chief alarm-system main computer over a high-speed CAN network.
How many alarm groups does it support?
It provides 13 alarm groups, plus a common machinery-alarm lamp and a repeat common machinery-alarm indication.
What supply voltage does it require?
The WCC 600 requires an 18 to 32 VDC supply and consumes 5 W.
What environmental ratings apply?
The panel is rated IP44, operates from -15°C to +70°C, and has IACS E10 and IEC 60945 environmental properties.
Documented Performance Data
| Metric | Value/range | Test/operating condition |
|---|---|---|
| Power consumption | 5 W | WCC 600 operating specification |
| Supply voltage | 18 to 32 VDC | WCC 600 operating specification |
| Operating temperature | -15°C to +70°C | WCC 600 operating specification |
| Ingress protection | IP44 | WCC 600 operating specification |

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626