Krohne OPTISONIC 6300 Ultrasonic Clamp-On Flowmeter

  • Model: OPTISONIC 6300 (Combination of OPTISONIC 6000 Rail Sensor + UFC 300 Converter)
  • Brand: Krohne
  • Series: OPTISONIC Series
  • Core Function: Non-invasive liquid flow velocity and volumetric measurement
  • Product Type: Ultrasonic Clamp-On Flowmeter System
  • Key Specs: Pipe Line Sizes DN15–DN4000 (1/2″–160″) | Velocity Range 0.1 to 20 m/s | Up to +200°C Liquid Temp
  • Condition: New Original / New Surplus (Never refurbished).
  • Inventory Status: High-demand process spare requiring strategic buffer stocking to resolve flow verification gaps without line cuts.
Categories: , , , , SKU: 6300 Brand:

Description

Key Technical Specifications

Parameter Value
Measurement Principle Ultrasonic Transit Time Difference
Pipe Size Range DN15 to DN4000 (1/2″ to 160″)
Velocity Range 0.1 to 20 m/s (Turn-down ratio 200:1)
Fluid Temperature Range Standard: -40 to +120 °C; XT Version: Up to +200 °C (+392 °F)
Signal Converter Unit UFC 300 (Wall-mount UFC 300 W or Field-mount UFC 300 F)
Analog / Digital Outputs 4–20 mA (HART 7), Pulse, Frequency, Status, Limit switch
Digital Communications Modbus RTU, Profibus PA/DP, Foundation Fieldbus
Sensor Rail Construction Stainless steel clamp-on mounting rail with IP68 / NEMA 6P options
Diagnostic Functionality Integrated NAMUR NE107 diagnostics, signal-to-noise monitoring
Power Supply Options 100–230 VAC (50/60 Hz) or 24 VAC/DC

 

Product Introduction & Supply Chain Strategy

The Krohne OPTISONIC 6300 is a stationary ultrasonic clamp-on flowmeter designed for accurate, non-intrusive flow rate measurement of liquid media across metal, plastic, and lined piping systems. By utilizing external sensor rails paired with the UFC 300 signal converter, the system measures clean or moderately contaminated process liquids without interrupting line pressure, dropping flow, or cutting pipe runs.

Maintaining this flowmeter system as a factory-certified New Surplus asset is an essential procurement strategy for process uptime. Because emergency flow verification often arises during unannounced inline meter failures, waiting on standard OEM factory build schedules exposes plants to prolonged off-spec batch risks. Sourcing genuine, uninstalled surplus eliminates component degradation risks common to second-hand refurbished units, maintaining low Total Cost of Ownership (TCO) while guaranteeing immediate field availability.

 

Installation & Configuration Guide

1.Pre-Installation (Prep & Safety):Prerequisite.

Isolate the electrical power supply to the field mounting enclosure before wiring the UFC 300 transmitter. Don appropriate ESD protection. Clean the outer pipe surface thoroughly using a wire brush or emery cloth to remove rust, paint flakes, or scale down to smooth metal at the transducer contact zone.

Verification: Measure pipe outer diameter (OD) and wall thickness using an ultrasonic thickness gauge, confirming values match parameters required for converter setup.

2.Removal & Sensor Positioning:Mechanical Mounting.

Mount the stainless steel sensor rail onto the pipe using the supplied metal fixing straps. Apply an even layer of acoustic coupling gel or pyrogel pads to the face of each OPTISONIC 6000 transducer. Adjust transducer distance according to the spacing calculated by the UFC 300 converter interface.

Verification: Verify that the transducers sit flush against the pipe wall without air gaps or physical misalignment.

3.Installation (Wiring & Integration):Signal Connection.

Connect the pre-assembled sensor signal cables to the designated input terminals of the UFC 300 converter. Route analog 4–20 mA / HART or digital bus communications (Modbus, Profibus) into the terminal chamber using IP67-rated cable glands.

Verification: Perform a ground continuity test to ensure signal shield wires are grounded at a single point to prevent ground loops.

4.Power-On & Setup:Commissioning.

Apply operating voltage to the UFC 300 converter. Navigate the backlit LCD interface to input pipe material, liner thickness, fluid sound velocity, and kinematic viscosity parameters. Run the diagnostic signal strength check.

Verification: Confirm that the acoustic signal quality indicator reads within acceptable operating bounds and the NAMUR NE107 status displays a normal green status.

OPTISONIC 6300

OPTISONIC 6300

OPTISONIC 6300

OPTISONIC 6300

Firmware/Software Versions & Upgrade Notes

  • Recommended Baseline: Ensure the UFC 300 converter firmware matches your plant’s standard DCS/PLC driver revision profile (e.g., HART 7 EDD profiles or specific GSD files for Profibus DP).
  • Compatibility Warnings: The OPTISONIC 6000 sensor rails are tuned to work directly with UFC 300 platform electronics. Avoid connecting legacy UFC 010 or UFC 50 converters directly without verifying impedance and signal gain parameters.
  • Configuration Retention & Flashing: Parameter settings (pipe dimensions, fluid profiles) are stored in non-volatile memory within the UFC 300. Back up parameter trees to the internal display module or via HART software before executing any system firmware updates.

 

Frequently Asked Questions (FAQ)

  • Why buy this Krohne OPTISONIC 6300 as New Surplus rather than factory lead-time order?

    Factory lead times for non-standard ultrasonic flowmeters can extend for weeks. Our New Surplus units provide instant dispatch for immediate installation during emergency maintenance windows without sacrificing factory-grade reliability.

  • How do I verify this flowmeter system is uninstalled and zero-wear?

    Every unit passes strict inbound inspection checks. We guarantee zero mechanical wear on mounting rail tracks, undamaged transducer face surfaces, factory-sealed terminal compartments, and original OEM serial tags.

  • Can the OPTISONIC 6300 be installed without shutting down process flow?

    Yes. Because the system utilizes non-invasive clamp-on sensor technology, installation occurs entirely on the exterior of the pipe wall. No pipe cutting, drilling, or process interruption is required.

  • What are the key failure modes of buying refurbished or second-hand ultrasonic transducers?

    Used or refurbished ultrasonic transducers frequently suffer from piezo-crystal degradation, micro-fractures caused by over-torquing, and dried internal acoustic seals. These defects lead to severe signal attenuation, zero-point drift, and spurious flow readings.

  • What warranty is provided with this system?

    This unit is backed by a full 1-year replacement warranty, delivering total operational peace of mind and matching standard OEM performance guarantees.