Description
3. Key Technical Specifications
| Parameter | Value |
|---|---|
| Model / Article | KSD1-08 / 00-122-284 |
| Type | Single-axis servo drive module |
| Compatibility | KUKA KR C2 / KR C2 ed05 controllers |
| DC Bus Input Voltage | 0–565/675 V DC (2-phase) |
| DC Bus Input Current | approx. 4.9/3.9 A |
| AC Output Voltage | 3-phase 0–400/480 V AC |
| Rated Output Current | 4.0/3.2 A continuous |
| Peak / Acceleration Current | 8 A (1 s) |
| Standstill Current | 5.1 A |
| Output Frequency | 0–480 Hz |
| Control Method | Field-oriented / vector control |
| Interfaces | Encoder (resolver or sine-cosine), Interbus-S, RS-485, PTC/KTY temp sensor, 24 V / 2 A brake output |
| Cooling | Forced air (integral fan) |
| Protection Class | IP20 |
| Weight | approx. 1.7–1.9 kg (3.75 lbs) |
| Dimensions (approx.) | 90 × 180 × 240 mm |
4. Product Introduction
The KUKA KSD1-08 (00-122-284) is a single-axis servo drive module used in KRC2 and KR C2 ed05 robot controllers. It converts the shared DC bus voltage into regulated three-phase power for low-to-medium power axes on robots such as the KR6, KR10, and KR16 series.
It delivers continuous 4 A output with 8 A peak capability, supports resolver or sine-cosine feedback, and includes motor temperature monitoring plus a 24 V brake output. The module mounts directly on the KUKA drive rail and communicates via Interbus-S. Because the original manufacturer has discontinued it, tested new-surplus units remain the practical replacement for keeping older KRC2 cells running.

KSD1-08

KSD1-08
5. Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| No LEDs or fan on power-up | Missing 24 V logic or DC bus | ❌ Low | Measure 24 V logic and DC bus at the module connectors | Check power supply and fuses first |
| Axis does not move, other axes OK | Drive fault or encoder fault | ✅ High | Read diagnostic buffer in KUKA software; check LED status | Swap with known-good KSD1-08 if buffer shows drive error |
| Intermittent “Communication Timeout” | Interbus connection or firmware mismatch | ✅ High | Reseat Interbus connector; verify module firmware version | Confirm firmware matches the rest of the rack |
| Over-temperature trip | Blocked fan or high ambient | ✅ Medium | Verify fan spins freely; measure heatsink temperature | Clean filters; improve cabinet airflow |
| Motor brake fails to release | 24 V brake output missing | ✅ High | Measure 24 V at brake terminals during enable | Check brake wiring and 24 V supply |
| All axes dead after swap | Incorrect DC bus polarity or short | ❌ Low | Verify polarity and measure resistance to ground | Never hot-swap; power down completely before install |
If the diagnostic buffer and LED status do not clearly point to the drive, capture photos of the LEDs, the diagnostic log, and the physical installation, then contact technical support before replacing the module.
6. Frequently Asked Questions (FAQ)
Q: Is the KSD1-08 still available new from KUKA?
No. KUKA discontinued the KSD1 series years ago. What remains on the market is new surplus (never installed, original packaging or carefully stored) or fully tested refurbished units. We supply only units that have passed functional load testing.
Q: Can I hot-swap a KSD1-08?
No. Power the entire controller down, wait for the DC bus capacitors to discharge, then remove and install the module. Hot-swapping risks damaging the backplane or the new drive.
Q: Will a KSD1-08 work as a direct replacement for any KRC2 axis?
It is the correct size for the lower-power axes (typically axes 4–6 on smaller robots such as KR6–KR16). Confirm the current rating of the axis you are replacing. Larger axes require KSD1-16, -32, -48 or -64 modules.
Q: Do I need to reprogram or reload parameters after swapping the drive?
Normally no. The KRC2 controller stores the axis parameters. However, always document the firmware version of the old module before removal. A large firmware mismatch can cause communication faults.
Q: What is the difference between “New Surplus” and “Refurbished”?
New Surplus units have never been installed in a robot. They receive full visual inspection, anti-counterfeit checks, and functional testing on a KRC2 rack. Refurbished units have been previously used, thoroughly cleaned, component-level repaired if needed, and load-tested under the same conditions.
Q: What common installation mistakes should I avoid?
- Failing to photograph the old module’s connectors and any jumpers before removal.
- Ignoring ESD protection—always wear a grounded wrist strap.
- Mixing firmware versions across the drive rack without checking compatibility.
- Re-using damaged Interbus connectors or cables.
Keep these points in mind and the swap is usually straightforward.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626